National Foreword
FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General requirements
5 General notes on tests
6 Marking
7 Terminations
8 Creepage distances and clearances
9 Voltage rating
10 Fuses
11 Discharge resistors
12 Testing sequence
13 Sealing and heating test
14 High-voltage test
15 Resistance to adverse operating conditions
16 Resistance to heat, fire and tracking
17 Self-healing test
18 Destruction test
Annex A (normative) - Test voltage
Annex B (normative) - Temperature adjustment of test
        Enclosure
Annex C (normative) - Test for conformity of manufacture
Annex D (informative) - Guide to calculating equipment
        settings for tests in 15.2 and 18.1.3
Annex E (normative) - Additional requirements for built-in
        capacitors having an insulation equivalent to
        double or reinforced insulation
Annex F (informative) - Information for luminaire design
Annex ZA (normative) - Normative references to
         international publications with their
         corresponding European publications
Bibliography

Describes the requirements for both self-healing and non-self-healing continuously rated a.c. capacitors of up to and including 2,5 kVAr, and not less than 0,1 [mu]F, having a rated voltage not exceeding 1000 V, which are intended for use in discharge lamp circuits operating at 50 Hz or 60 Hz and at altitudes up to 3000 m.

DevelopmentNote
For CENELEC adoptions of IEC publications, please check www.iec.ch to be sure that you have any corrigenda that may apply. (01/2017)
DocumentType
Standard
Pages
102
PublisherName
National Standards Authority of Ireland
Status
Current

Standards Relationship
UNE-EN 61048:2007 Identical
DIN EN 61048 : 2016 Identical
NF EN 61048 : 2006 AMD 1 2016 Identical
EN 61048:2006/A1:2016 Identical
NBN EN 61048 : 2006 AMD 1 2016 Identical
BS EN 61048 : 2006 Identical

IEC 60384-14:2013+AMD1:2016 CSV Fixed capacitors for use in electronic equipment - Part 14: Sectional specification - Fixed capacitors for electromagnetic interference suppression and connection to the supply mains
IEC 60662:2011 High-pressure sodium vapour lamps - Performance specifications
IEC 60192:2001 Low-pressure sodium vapour lamps - Performance specifications
IEC 60188:2001 High-pressure mercury vapour lamps - Performance specifications
IEC 61347-2-9:2012 Lamp controlgear - Part 2-9: Particular requirements for electromagnetic controlgear for discharge lamps (excluding fluorescent lamps)
IEC 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT)
IEC 61167:2015 Metal halide lamps - Performance specification
IEC 60410:1973 Sampling plans and procedures for inspection by attributes
IEC 61049:1991 Capacitors for use in tubular fluorescent and other discharge lamp circuits. Performance requirements
EN 61049:1993 Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements
IEC 60901:1996+AMD1:1997+AMD2:2000 CSV Single-capped fluorescent lamps - Performance specifications
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60598-1:2014+AMD1:2017 CSV Luminaires - Part 1: General requirements and tests
ISO 4046-4:2002 Paper, board, pulps and related terms Vocabulary Part 4: Paper and board grades and converted products
EN 60529:1991/AC:2016-12 DEGREES OF PROTECTION PROVIDED BY ENCLOSURES (IP CODE) (IEC 60529 EDITION 2.2 CORRIGENDUM 2:2015)
EN 60695-11-5:2017 Fire hazard testing - Part 11-5: Test flames - Needle-flame test method - Apparatus, confirmatory test arrangement and guidance
IEC 60695-11-5 : 2.0 FIRE HAZARD TESTING - PART 11-5: TEST FLAMES - NEEDLE-FLAME TEST METHOD - APPARATUS, CONFIRMATORY TEST ARRANGEMENT AND GUIDANCE
IEC 61347-2-8:2000+AMD1:2006 CSV Lamp controlgear - Part 2-8: Particular requirements for ballasts for fluorescent lamps
EN 60695-2-11:2014 Fire hazard testing - Part 2-11: Glowing/hot-wire based test methods - Glow-wire flammability test method for end-products (GWEPT) (IEC 60695-2-11:2014)

View more information
US$70.16
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.