FOREWORD
INTRODUCTION
1 Scope
2 Normative references
  2.1 General standards
  2.2 Immunity standards
  2.3 Emission standards
3 Definitions
4 General
5 EMC test plan
  5.1 General
  5.2 Configuration of EUT during testing
      5.2.1 General
      5.2.2 Composition of EUT
      5.2.3 Assembly of EUT
      5.2.4 I/O ports
      5.2.5 Auxiliary equipment
      5.2.6 Cabling and earthing (grounding)
  5.3 Operation conditions of EUT during testing
      5.3.1 Operation modes
      5.3.2 Environmental conditions
      5.3.3 EUT software during test
  5.4 Specification of performance criteria
  5.5 Test description
6 Immunity requirements
  6.1 Conditions during the tests
  6.2 Immunity test requirements
  6.3 System and application aspects
  6.4 Random aspects
  6.5 Performance criteria
7 Emission requirements
  7.1 Conditions during measurements
  7.2 Emission limits
8 Test results and test report
Annex A (normative) Immunity test requirements for
                     equipment intended for use in
                     industrial locations
Annex B (normative) Immunity test requirements for equipment
                     used in controlled EM environments
Annex C (normative) Immunity test requirements for portable
                     test and measurement equipment
Annex D (normative) Test configurations, operational
                     conditions and performance criteria
                     conditions and performance criteria
                     for sensitive test and measurement
                     equipment for EMC unprotected
                     applications
Annex E (normative) Test configurations, operational conditions
                     and performance criteria for portable test,
                     measuring and monitoring equipment used
                     in low-voltage distribution systems
Annex F (normative) Test configurations, operational
                     conditions and performance criteria for
                     transducers with integrated or remote
                     signal conditioning
Annex ZA (normative) Normative references to international
                     publications with their corresponding
                     European publications

Defines minimum requirements for immunity and emissions regarding electromagnetic compatibility (EMC) for electrical equipment, which operates from a supply of less than 1000 V a.c. or 1500 V. d.c. or from the circuit being measured, intended for professional, industrial-process and educational use.

IEC 61000-4-8 : 2.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-8: TESTING AND MEASUREMENT TECHNIQUES - POWER FREQUENCY MAGNETIC FIELD IMMUNITY TEST
CISPR 14-1:2016 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 61000-4-1:2006 Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series
EN 61000-4-11:2004/A1:2017 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-11: TESTING AND MEASUREMENT TECHNIQUES - VOLTAGE DIPS, SHORT INTERRUPTIONS AND VOLTAGE VARIATIONS IMMUNITY TESTS (IEC 61000-4-11:2004/A1:2017)
IEC 60050-151:2001 International Electrotechnical Vocabulary (IEV) - Part 151: Electrical and magnetic devices
EN 61000-3-3:2013 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION (IEC 61000-3-3:2013)
EN 61000-4-2:2009 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEEE 488.1 : 2003 STANDARD FOR HIGHER PERFORMANCE PROTOCOL FOR THE STANDARD DIGITAL INTERFACE FOR PROGRAMMABLE INSTRUMENTATION
IEC 61000-4-6 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS
CISPR 16:1987 CISPR specification for radio interference measuring apparatus and measurement methods
CISPR 22:2008 Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement
EN 61000-4-3 : 2006 AMD 2 2010 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-3: TESTING AND MEASUREMENT TECHNIQUES - RADIATED, RADIO-FREQUENCY, ELECTROMAGNETIC FIELD IMMUNITY TEST
EN 55022:2010/AC:2011 INFORMATION TECHNOLOGY EQUIPMENT - RADIO DISTURBANCE CHARACTERISTICS - LIMITS AND METHODS OF MEASUREMENT (CISPR 22:2008)
CISPR 16-2:2003 Specification for radio disturbance and immunity measuring apparatus and methods - Part 2: Methods of measurement of disturbances and immunity
EN 61000-4-8:2010 Electromagnetic compatibility (EMC) - Part 4-8: Testing and measurement techniques - Power frequency magnetic field immunity test
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
EN 61000-3-2:2014 Electromagnetic compatibility (EMC) - Part 3-2: Limits - Limits for harmonic current emissions (equipment input current ≤ 16 A per phase)
IEC 61000-3-3 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-3: LIMITS - LIMITATION OF VOLTAGE CHANGES, VOLTAGE FLUCTUATIONS AND FLICKER IN PUBLIC LOW-VOLTAGE SUPPLY SYSTEMS, FOR EQUIPMENT WITH RATED CURRENT <= 16 A PER PHASE AND NOT SUBJECT TO CONDITIONAL CONNECTION
EN 61000-4-4:2012 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST (IEC 61000-4-4:2012)
CISPR 11:2015 RLV Industrial, scientific and medical equipment - Radio-frequency disturbance characteristics - Limits and methods of measurement
EN 61000-4-6:2014/AC:2015 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-6: TESTING AND MEASUREMENT TECHNIQUES - IMMUNITY TO CONDUCTED DISTURBANCES, INDUCED BY RADIO-FREQUENCY FIELDS (IEC 61000-4-6:2013)
CISPR 16-1:1999+AMD1:2002 CSV Specification for radio disturbance and immunity measuring apparatus and methods - Part 1: Radio disturbance and immunity measuring apparatus
EN 55014-1:2017 Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission
IEC 61000-3-2 : 4.0 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE)

View more information
US$70.16
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.