• There are no items in your cart

I.C.P. 1:1966

Withdrawn

Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

COPPER ROOF COVERING

Available format(s)

Hardcopy , PDF

Withdrawn date

05-03-2017

Language(s)

English

Published date

01-01-1966

Preview

FOREWORD
SECTION 1: GENERAL
101 Scope
102 Definitions
103 Drawings and Specification
SECTION 2: MATERIALS, APPLIANCES AND COMPONENTS
201 Characteristics of material
202 Copper
203 Nails
204 Screws
205 Felt
206 Solder
SECTION 3: DESIGN CONSIDERATIONS
301 Substructure, (a) General
                  (b) Concrete
                  (c) Timber
                  (d) Other decking materials
                  (e) Falls and drips on roofs
                  (f) Falls and drips in gutters
302 Copper roofing systems
303 Copper roof coverings
304 Rolls
305 Special features, (a) Edge details
                      (b) Expansion joints
                      (c) Ridge and hip details
                      (d) Valleys
                      (e) Verges
                      (f) General
306 Thermal insulation
307 Ventilation
308 Fire resistance
309 Weight
310 Protection against lighting
SECTION 4: METHODS OF LAYING AND WORKMANSHIP
401 Protection and storage
402 Preparatory work
403 Sequence of operations
404 Setting out the work
405 Felting
406 Technique of laying copper sheeting
407 Standing seams
    (a) Clips for standing seams
    (b) Double cross clinks
    (c) Ridge and hips
    (d) Standing seam to square abutment
408 Wood roll systems
    (a) Conical roll
    (b) Square roll
    (c) Triangular roll
    (d) Clips for rolls
    (e) Cross clinks
    (f) Roll to square abutment
    (g) Ridge and hips
    (h) Cap ends
409 Parapet and box gutters
410 Cesspools
411 Details (a) Drips
            (b) Square abutments
            (c) Aprons and flashings
            (d) Eaves and verges
            (e) Clips
            (f) Jointing by solder
SECTION 5: INSPECTION AND TESTING
501 Preparatory work
    (a) Substructure
    (b) Copper sheet
    (c) Felt
502 Work in progress
503 Completion
Appendix A Properties of Copper

Lays down minimum requirements for copper roof coverings. Materials, appliances and components are listed together with design considerations, methods of laying and workmanship and procedure for inspection and testing.

DocumentType
Standard
Pages
60
PublisherName
National Standards Authority of Ireland
Status
Withdrawn

View more information
US$58.10
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.