• There are no items in your cart

IEC 60068-3-3:1991

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Environmental testing - Part 3-3: Guidance - Seismic test methods for equipments
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

12-31-2021

Language(s)

English - French, Russian, Spanish, Castilian

Published date

02-28-1991

FOREWORD
PREFACE
INTRODUCTION
SECTION ONE - GENERAL
Clause
1 Object
2 General considerations
3 Definitions
4 Qualification considerations
5 Testing procedures
SECTION TWO - GENERAL SEISMIC CLASS
6 Conditioning
7 Standard amplitude conventional test method
8 Calculated amplitude test method
9 Testing parameters
10 Testing procedures
SECTION THREE - SPECIFIC SEISMIC CLASS
11 Conditioning
12 Test wave selection
13 Test waves
14 Testing conditions
15 Single and multiaxis testing
FIGURES
APPENDIX A - Flow charts for test selection

IEC 60068-3-3:1991 Guidance is included in each of the three test methods referred to in this standard but it is specific to the test method. The guidance in this standard is directed towards choosing the appropriate test method and applying it to seismic testing.

Committee
TC 104
DevelopmentNote
Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
83
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy

CSA S832 : 2014 SEISMIC RISK REDUCTION OF OPERATIONAL AND FUNCTIONAL COMPONENTS (OFCS) OF BUILDINGS
BS EN 60143-4:2010 Series capacitors for power systems Thyristors controlled series capacitors
02/210916 DC : DRAFT OCT 2002 IEC 62271-002 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 002: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
CEI EN 60068-2-57 : 2014 ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME HISTORY AND SINE-BEAT METHOD
BS EN 62040-5-3:2017 Uninterruptible power systems (UPS) DC output UPS. Performance and test requirements
CEI EN 62271-207 : 2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
BS EN 61758-1:2008 Fibre optic interconnecting devices and passive components. Interface standard for closures General and guidance
17/30347294 DC : 0 BS EN 60076-22-1 - POWER TRANSFORMER AND REACTOR FITTINGS - PART 22-1: PROTECTIVE DEVICES
BS EN 60068-2-57:2013 Environmental testing Tests. Test Ff: Vibration. Time-history and sine-beat method
07/30167951 DC : 0 BS EN 60076-1 - POWER TRANSFORMERS - PART 1: GENERAL
I.S. EN 60143-4:2010 SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS
NF EN 60068-2-57 : 2013 ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME-HISTORY AND SINE-BEAT METHOD
I.S. EN 60068-2-57:2013 ENVIRONMENTAL TESTING - PART 2-57: TESTS - TEST FF: VIBRATION - TIME-HISTORY AND SINE-BEAT METHOD (IEC 60068-2-57:2013 (EQV))
EN 50216-2 : 2002 AMD 1 2002 POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR
EN 61758-1:2008 Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance
EN 50216-1:2002 Power transformer and reactor fittings - Part 1: General
EN 62040-5-3:2017 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements
EN 61587-2:2011 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS (IEC 61587-2:2011)
EN 60255-21-3:1995 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests
01/203455 DC : DRAFT MAY 2001 IEC 60143-1 ED.4.0 - SERIES CAPACITORS FOR POWER SYSTEMS
BS EN 50216-2:2002 Power transformers and reactor fittings Gas and oil actuated relay for liquid immersed transformers and reactors with conservator
BS EN 61587-5:2014 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Seismic tests for chassis, subracks and plug-in units
BS 142-1.5.3(1993) : 1993 AMD 8833 ELECTRICAL PROTECTION RELAYS - INFORMATION AND REQUIREMENTS FOR ALL PROTECTION RELAYS - VIBRATION, SHOCK, BUMP AND SEISMIC TESTING - SEISMIC TESTS
05/30132701 DC : DRAFT APR 2005 IEC 62271-300 ED 1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 300: SEISMIC QUALIFICATION OF ALTERNATING CURRENT CIRCUIT-BREAKERS
EN 60780-323 : 2017 Nuclear facilities - Electrical equipment important to safety - Qualification
CEI EN 61587-2 : 2012 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS
BS IEC/IEEE 60780-323 : 2016 NUCLEAR FACILITIES - ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY - QUALIFICATION
I.S. EN 61587-2:2011 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 2: SEISMIC TESTS FOR CABINETS AND RACKS (IEC 61587-2:2011)
08/30179134 DC : DRAFT MAR 2008 BS EN 60143-4 - SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS
NF EN 300019 1-4 : 2014 ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATIONS EQUIPMENT - PART 1-4: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT NON-WEATHERPROTECTED LOCATIONS (V2.2.1)
IEC TR 62271-300:2006 High-voltage switchgear and controlgear - Part 300: Seismic qualification of alternating current circuit-breakers
CEI EN 61587-5 : 2014 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS AND PLUG-IN UNITS
I.S. EN 61587-5:2014 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS AND PLUG-IN UNITS
CEI EN 50216-1 : 2002 POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL
I.S. EN 62040-5-3:2017 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: DC OUTPUT UPS - PERFORMANCE AND TEST REQUIREMENTS
CEI EN 60143-4 : 2012 SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS
IEC TS 62271-210:2013 High-voltage switchgear and controlgear - Part 210: Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV
I.S. EN 62040-3:2011 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
UNE-EN 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
CEI EN 62040-3 : 2015 UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS
NF EN 62271-2 : 2004 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
NF EN 300019-1-3 : 2014 ENVIRONMENTAL ENGINEERING (EE) - ENVIRONMENTAL CONDITIONS AND ENVIRONMENTAL TESTS FOR TELECOMMUNICATION EQUIPMENT - PART 1-3: CLASSIFICATION OF ENVIRONMENTAL CONDITIONS - STATIONARY USE AT WEATHERPROTED LOCATIONS (V2.4.1)
BS IEC 60780:1998 Nuclear power plants. Electrical equipment of the safety system. Qualification
14/30297921 DC : 0 BS EN 62040-5-3 - UNINTERRUPTIBLE POWER SYSTEMS (UPS) - PART 5-3: METHOD OF SPECIFYING THE PERFORMANCE AND TEST REQUIREMENTS FOR D.C. UPS
10/30232728 DC : 0 BS EN 62271-207 ED 2 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
BS EN 60076-1:2011 Power transformers General
09/30211740 DC : 0 BS EN 62271-210 ED1 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 210: SEISMIC QUALIFICATION FOR METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
I.S. EN 50216-2:2002 POWER TRANSFORMER AND REACTOR FITTINGS - PART 2: GAS AND OIL ACTUATED RELAY FOR LIQUID IMMERSED TRANSFORMERS AND REACTORS WITH CONSERVATOR
BS EN 62271-2:2003 High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above
IEC TS 60076-23:2018 Power transformers - Part 23: DC magnetic bias suppression devices
EN 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC/IEEE 60780-323:2016 Nuclear facilities - Electrical equipment important to safety - Qualification
I.S. EN 61758-1:2008 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - INTERFACE STANDARD FOR CLOSURES - PART 1: GENERAL AND GUIDANCE
BS EN 62040-3:2011 Uninterruptible power systems (UPS) Method of specifying the performance and test requirements
I.S. EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012 (EQV))
CEI EN 61758-1 : 2010 FIBRE OPTIC INTERCONNECTING DEVICES AND PASSIVE COMPONENTS - INTERFACE STANDARD FOR CLOSURES - PART 1: GENERAL AND GUIDANCE
IEC 60780:1998 Nuclear power plants - Electrical equipment of the safety system - Qualification
IEC 60143-4:2010 Series capacitors for power systems - Part 4: Thyristor controlled series capacitors
CEI 45-60 : 2009 NUCLEAR POWER PLANTS - ELECTRICAL EQUIPMENT OF THE SAFETY SYSTEM - QUALIFICATION
BS EN 60780-323:2017 Nuclear facilities. Electrical equipment important to safety. Qualification
05/30134423 DC : DRAFT JUN 2005 IEC 62271-207 - HV SWITCHGEAR ASSEMBLIES - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
CEI EN 60255-21-3 : 1998 ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS
BS EN 50216-1:2002 Power transformers and reactor fittings General
PD IEC/TS 61463:2016 Bushings. Seismic qualification
IEC TS 61463:2016 Bushings - Seismic qualification
11/30249337 DC : 0 BS EN 61587-5 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 5: SEISMIC TESTS FOR CHASSIS, SUBRACKS, AND ASSOCIATED PLUG-IN UNIT
15/30249614 DC : 0 BS IEC/IEEE 60780-323 ED 1.0 - NUCLEAR FACILITIES - ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY - QUALIFICATION
BS EN 62271-207:2012 High-voltage switchgear and controlgear Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
10/30216308 DC : 0 BS EN 60068-2-57:2000+A1 - ENVIRONMENTAL TESTING - PART 2-57: TEST METHODS - TEST FF: VIBRATION - TIME-HISTORY & SINE-BEAT METHOD
BS 2011-2.1FE(1991) : 1991 AMD 7841 ENVIRONMENTAL TESTING - TESTS - TEST FE AND GUIDANCE - VIBRATION (SINE-BEAT METHOD)
I.S. EN 62271-2:2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
I.S. EN 50216-1:2002 POWER TRANSFORMER AND REACTOR FITTINGS - PART 1: GENERAL
I.S. EN 60780-323:2017 NUCLEAR FACILITIES - ELECTRICAL EQUIPMENT IMPORTANT TO SAFETY - QUALIFICATION
CEI EN 60076-1 : 2015 POWER TRANSFORMERS - PART 1: GENERAL
UNE-EN 60076-1:2013 Power transformers - Part 1: General
IEC 62040-5-3:2016 Uninterruptible power systems (UPS) - Part 5-3: DC output UPS - Performance and test requirements
IEC 61166:1993 High-voltage alternating current circuit-breakers - Guide for seismic qualification of high-voltage alternating current circuit-breakers
IEC 61747-1:1998+AMD1:2003 CSV Liquid crystal and solid-state display devices - Part 1: Generic specification
IEC 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
IEC 60076-1:2011 Power transformers - Part 1: General
IEC 61587-5:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units
IEC 62040-3:2011 Uninterruptible power systems (UPS) - Part 3: Method of specifying the performance and test requirements
IEC 61587-2:2011 Mechanical structures for electronic equipment - Tests for IEC 60917 and 60297 - Part 2: Seismic tests for cabinets and racks
IEC 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
IEC 61758-1:2008 Fibre optic interconnecting devices and passive components - Interface standard for closures - Part 1: General and guidance
NF EN 60255 21-3 : 1998 ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS
PD IEC/TS 62271-210:2013 High-voltage switchgear and controlgear Seismic qualification for metal enclosed and solid-insulation enclosed switchgear and controlgear assemblies for rated voltages above 1 kV and up to and including 52 kV
16/30349321 DC : 0 BS EN 60076-11 ED 2.0 - POWER TRANSFORMERS - PART 11: DRY-TYPE TRANSFORMERS
BS EN 61587-2:2011 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Seismic tests for cabinets and racks
I.S. EN 60255-21-3:1997 ELECTRICAL RELAYS - PART 21: VIBRATION, SHOCK, BUMP AND SEISMIC TESTS ON MEASURING RELAYS AND PROTECTION EQUIPMENT - SECTION 3: SEISMIC TESTS
I.S. EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)
NF EN 60068 2-59 : 1994 ENVIRONMENTAL TESTING - PART 2: TEST METHODS - TEST FE: VIBRATION SINE BEAT METHOD
IEC 60300-3-5:2001 Dependability management - Part 3-5: Application guide - Reliability test conditions and statistical test principles
IEC 60255-21-3:1993 Electrical relays - Part 21: Vibration, shock, bump and seismic tests on measuring relays and protection equipment - Section 3: Seismic tests
IEC 62271-207:2012 High-voltage switchgear and controlgear - Part 207: Seismic qualification for gas-insulated switchgear assemblies for rated voltages above 52 kV
EN 62271-207:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV (IEC 62271-207:2012)
EN 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
EN 60068-2-57:2013 Environmental testing - Part 2-57: Tests - Test Ff: Vibration - Time-history and sine-beat method
EN 60143-4 : 2010 SERIES CAPACITORS FOR POWER SYSTEMS - PART 4: THYRISTOR CONTROLLED SERIES CAPACITORS
EN 61587-5:2014 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 5: Seismic tests for chassis, subracks and plug-in units
EN 60076-1:2011 POWER TRANSFORMERS - PART 1: GENERAL (IEC 60076-1:2011)

View more information
US$313.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.