• There are no items in your cart

IEC 60517:1990

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

11-06-2003

Published date

10-15-1990

FOREWORD
Clause
1 Scope
2 Normal and special service conditions
3 Definitions
4 Rating
   4.1 Rated voltage
   4.2 Rated insulation level
   4.3 Rated frequency
   4.4 Rated normal current and temperature rise
   4.5 Rated short-time withstand current
   4.6 Rated peak withstand current
   4.7 Rated duration of short-circuit
   4.8 Rated supply voltage of closing and opening devices
         and auxiliary circuits
   4.9 Rated supply frequency of opening devices and
         auxiliary circuits
   4.10 Rated pressure of compressed gas supply for
         operating mechanisms
   4.101 Rated density of gas for insulation
5 Design and construction
   5.1 Requirements for liquids in switchgear and controlgear
   5.2 Requirements for gases in switchgear and controlgear
   5.3 Earthing
   5.4 Auxiliary equipment
   5.5 Dependent power closing
   5.6 Stored energy closing
   5.7 Operation of releases
   5.8 Low and high pressure interlocking devices
   5.9 Nameplates
   5.101 Degree of protection
   5.102 Internal fault
   5.103 Enclosures
   5.104 Partitions
   5.105 Pressure relief
   5.106 Disconnectors and earthing switches
   5.107 Interlocks
   5.108 Noise
   5.109 Provisions far dielectric tests on cables
6 Type tests
   6.1 Dielectric tests
   6.2 Radio interference voltage (RIV) tests
   6.3 Temperature-rise tests
   6.4 Measurement of the resistance of the main circuit
   6.5 Short-time and peak withstand current tests
   6.101 Verification of making and breaking capacities
   6.102 Mechanical operation tests
   6.103 Verification of the degree of protection for
         auxiliary circuits and moving parts
   6.104 Proof tests for enclosures
   6.105 Weatherproofing test
   6.106 Test under conditions of arcing due to an internal
         fault
   6.107 Thermal stability test
   6.108 Operation tests at limit temperatures
   6.109 Gas tightness tests
7 Routine tests
   7.1 Power-frequency voltage tests on the main circuit
   7.2 Dielectric tests on auxiliary and control circuits
   7.3 Measurement of the resistance of the main circuit
   7.101 Partial discharge measurement
   7.102 Pressure tests of enclosures
   7.103 Gas tightness tests
   7.104 Mechanical operation tests
   7.105 Tests of auxiliary electrical, pneumatic and
         hydraulic devices
   7.106 Verification of the correct wiring
   7.107 Tests after erection on site
8 Guide to the selection of the switchgear for service
9 Information to be given with enquiries, tenders and orders
   9.101 Information with enquiries and orders
   9.102 Information with tenders
10 Rules for transport, storage, erection and maintenance
   10.1 Conditions during transport, storage and erection
   10.2 Erection
   10.3 Maintenance
Annexes
AA - Recommended method for the weatherproofing test for
     outdoor gas-insulated metal-enclosed switchgear
BB - Methods for testing gas-insulated metal-enclosed
     switchgear under conditions or arcing due to an
     internal fault
CC - Technical and practical considerations of site testing
DD - Gas tightness specifications and tests

Specifies requirements for gas-insulated metal-enclosed switchgear in which the insulation is obtained, at least partly, by an insulating gas other than air at atmospheric pressure, for alternating current of rated voltages of 72.5 kV and above, for indoor and outdoor installation, and for service frequencies up to and including 60 Hz. For the purpose of this standard the term 'switchgear' is used for 'gas-insulated metal-enclosed switchgear'.

DevelopmentNote
BS DRAFTS 91/27712 DC & 93/200463 DC REFER TO AMENDMENT Also numbered as BS EN 60517 (06/2001)
DocumentType
Standard
Pages
125
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

BS EN 60298:1996 A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
02/210916 DC : DRAFT OCT 2002 IEC 62271-002 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 002: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
97/208495 DC : DRAFT JUL 1997 IEC 61640 - HV GAS-INSULATED TRANSMISSION LINES FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
CSA C50069 : 1999 : R2007 WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
CAN/CSA-C50069-99 (R2016) Welded Composite Enclosures of Cast and Wrought Aluminium Alloys for Gas-Filled High-Voltage Switchgear and Controlgear (Adopted CENELEC Standard EN 50069:1991 including Amendment A1:1993, with Canadian deviations)
NFC 33 062 : 1999 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SF6 INSULATED METAL ENCLOSED TERMINATIONS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
BS EN 50069 : 1991 SPECIFICATION FOR WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
EN 60298:1996/A11:1999 A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
EN 62271-102:2002/AC:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001/A2:2013)
04/30111589 DC : 0
BS EN 45510-2-7:2002 Guide for the procurement of power station equipment. Electrical equipment Switchgear and controlgear
BS 6904:1987 Guide for cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72.5 kV and above
CEI UNI EN 45510-2-7 : 2006 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
98/232755 DC : DRAFT DEC 1998 IEC 61936-1 - POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
CSA C22.3 No. 61936-1 : 2008 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
BS 5227:1992 Specification for a.c. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
DIN EN 50089 : 1994 AMD 1 1995 CAST RESIN PARTITIONS FOR METAL ENCLOSED GAS-FILLED HIGH VOLTAGE SWITCHGEAR AND CONTROLGEAR
NF EN 62271-2 : 2004 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 2: SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
UNE-EN 60137:2011 Insulated bushings for alternating voltages above 1 000 V
BS EN 62271-102 : 2002 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES
94/712993 DC : DRAFT NOV 1994 PREN 45511 - GUIDE FOR PROCUREMENT - ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
BIS IS/IEC 62271-200 : 2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UPTO AND INCLUDING 52 KV
CSA C50069 : 1999 : INC : UPD 1 : 1999 : R2012 WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
IEC TS 60859:1999 Cable connections for gas-insulated metal-enclosed switchgear for rated voltages of 72,5 kV and above - Fluid-filled and extruded insulation cables - Fluid-filled and dry type cable-terminations
EN 50069:1991/corrigendum Aug. 2007 WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
BS EN 62271-2:2003 High-voltage switchgear and controlgear Seismic qualification for rated voltages of 72,5 kV and above
05/30134423 DC : DRAFT JUN 2005 IEC 62271-207 - HV SWITCHGEAR ASSEMBLIES - PART 207: SEISMIC QUALIFICATION FOR GAS-INSULATED SWITCHGEAR ASSEMBLIES FOR RATED VOLTAGES ABOVE 52 KV
CSA C22.3 No. 61936-1 : 2008 : R2015 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
97/203920 DC : DRAFT MAR 1997 IEC 60859-2 - CABLE CONNECTIONS FOR GAS-INSULATED METAL-ENCLOSED SWITCHGEAR FOR RATED VOLTAGES OF 72,5 KV AND ABOVE - PART 2: PREFABRICATED 'DRY TYPE' CABLE TERMINATIONS FOR EXTRUDED INSULATION CABLES
16/30318517 DC : 0 BS EN 60137 ED. 7.0 - INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
BS 7315(1990) : 1990 SPECIFICATION FOR WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
UNI CEI EN 45510-2-7 : 2011 GUIDE FOR PROCUREMENT OF POWER STATION EQUIPMENT - PART 2-7: ELECTRICAL EQUIPMENT - SWITCHGEAR AND CONTROLGEAR
CSA C50069 : 1999 : INC : UPD 1 : 1999 : R2012 : FR WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
IEC PAS 62271-109:2002 High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches
I.S. EN 62271-2:2003 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - SEISMIC QUALIFICATION FOR RATED VOLTAGES OF 72,5 KV AND ABOVE
BS 6878(1988) : 1988 SPECIFICATION FOR HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR FOR INDUSTRIAL USE - CAST ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
I.S. EN 50069:1991 WELDED COMPOSITE ENCLOSURES OF CAST AND WROUGHT ALUMINIUM ALLOYS FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
IEC 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
EN 45510-2-7:2002 Guide for procurement of power station equipment - Part 2-7: Electrical equipment - Switchgear and controlgear
I.S. EN 62271-102:2005 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 102: ALTERNATING CURRENT DISCONNECTORS AND EARTHING SWITCHES (IEC 62271-102:2001 (EQV))
I.S. EN 50064:1991 WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
CEI EN 60137 : 2009 INSULATED BUSHINGS FOR ALTERNATING VOLTAGES ABOVE 1000 V
EN 62271-2:2003 High-voltage switchgear and controlgear - Part 2: Seismic qualification for rated voltages of 72,5 kV and above
EN 50064 : 1989 COR 2007 WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR

View more information
US$348.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.