FOREWORD
INTRODUCTION
Clause
1 Scope
2 Normative references
3 General
4 Definitions
5 Shielding performance designations
6 General test approach
7 Testing requirements
  7.1 Climatic conditions
  7.2 Test samples
  7.3 Analysis requirements
  7.4 Test frequency selection
  7.5 Test matrix definition
  7.6 Test equipment requirements
  7.7 Safety requirements
  7.8 Test plan requirements
  7.9 Test performance
  7.10 Test conclusions
  7.11 Test documentation
8 Classification
Annex A (informative) Some issues for selection of
        enclosure electromagnetic protection requirements
Annex B (informative) Summary of responsibilities of
        relevant end-product technical committees
Annex C (informative) Other test methods - TEM cells
        and striplines
Annex D (informative) Antennas
Bibliography

Describes performance requirements, test methods and classification procedures for degrees of protection provided by empty enclosures against electromagnetic disturbances for frequencies between 10 kHz and 40 GHz. The shielding protection is measured for the purpose of demonstrating that the enclosure provides adequate shielding of electromagnetic energy to support acceptable performance of the complete assembled units when tested to applicable IEC standards. The purpose of this standard is to provide a repeatable means for evaluating the electromagnetic shielding performance of empty mechanical enclosures, including cabinets and subracks, and to specify a marking code to allow a manufacturer to select an enclosure with a known capability for attenuating electromagnetic fields. The requirements for immunity to various types of electromagnetic disturbances, including lightning and high-altitude electro-magnetic pulse (HEMP) will need to be considered by manufacturers when determining the need for application of this standard for specific equipment and applications, and for the specific enclosure shielding requirements which are necessary as a function of frequency.

Committee
TC 77/SC 77C
DevelopmentNote
Stability date: 2018. (11/2017)
DocumentType
Standard
Pages
51
PublisherName
International Electrotechnical Committee
Status
Current

BS EN 61587-3:2013 Mechanical structures for electronic equipment. Tests for IEC 60917 and IEC 60297 Electromagnetic shielding performance tests for cabinets and subracks
09/30194273 DC : 0 BS EN 62208 - EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS
CEI EN 61587-3 : 2014 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS
13/30286075 DC : 0 BS EN 61000-4-36 ED 1.0 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-36: TESTING AND MEASUREMENT TECHNIQUES - IEMI IMMUNITY TEST METHODS FOR EQUIPMENT AND SYSTEMS
IEC 60694:1996+AMD1:2000+AMD2:2001 CSV Common specifications for high-voltage switchgear and controlgear standards
EN 62208:2011 Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements
PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
11/30254082 DC : 0 BS EN 61587-3 - MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS
BS EN 62208:2011 Empty enclosures for low-voltage switchgear and controlgear assemblies. General requirements
IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC) - Part 5-6: Installation and mitigation guidelines - Mitigation of external EM influences
CEI EN 62208 : 2012 EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS
IEC TS 61000-5-9:2009 Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM
IEEE 299.1-2013 IEEE Standard Method for Measuring the Shielding Effectiveness of Enclosures and Boxes Having all Dimensions between 0.1 m and 2 m
DD IEC/TS 61000-5-9:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM
UNE-EN 62208:2012 Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements
I.S. EN 61000-4-21:2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-21: TESTING AND MEASUREMENT TECHNIQUES - REVERBERATION CHAMBER TEST METHODS
BS EN 61000-4-21:2011 Electromagnetic compatibility (EMC) Testing and measurement techniques. Reverberation chamber test methods
I.S. EN 62208:2011 EMPTY ENCLOSURES FOR LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR ASSEMBLIES - GENERAL REQUIREMENTS (IEC 62208:2011)
IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI
IEC 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
IEC 62208:2011 Empty enclosures for low-voltage switchgear and controlgear assemblies - General requirements
PD IEC TR 61000-5-6:2002 Electromagnetic compatibility (EMC). Installation and mitigation guidelines Mitigation of external EM influences
92/03769 DC : DRAFT NOV 1992 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5: INSTALLATION AND MITIGATION GUIDELINES - SECTION 3: CABLING AND WIRING
I.S. EN 61587-3:2013 MECHANICAL STRUCTURES FOR ELECTRONIC EQUIPMENT - TESTS FOR IEC 60917 AND IEC 60297 - PART 3: ELECTROMAGNETIC SHIELDING PERFORMANCE TESTS FOR CABINETS AND SUBRACKS (IEC 61587-3:2013 (EQV))
IEC 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods
EN 61587-3:2013 Mechanical structures for electronic equipment - Tests for IEC 60917 and IEC 60297 - Part 3: Electromagnetic shielding performance tests for cabinets and subracks
EN 61000-4-21:2011 Electromagnetic compatibility (EMC) - Part 4-21: Testing and measurement techniques - Reverberation chamber test methods

IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test
IEC 60050-826:2004 International Electrotechnical Vocabulary (IEV) - Part 826: Electrical installations
IEC 61000-4-23:2016 Electromagnetic compatibility (EMC) - Part 4-23: Testing and measurement techniques - Test methods for protective devices for HEMP and other radiated disturbances

View more information
US$220.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.