• There are no items in your cart

IEC 61000-6-6:2003

Current

Current

The latest, up-to-date edition.

Electromagnetic compatibility (EMC) - Part 6-6: Generic standards - HEMP immunity for indoor equipment

Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English - French

Published date

04-09-2003

This part of IEC 61000 sets high-altitude electromagnetic pulse (HEMP) immunity requirements for electrical and electronic equipment intended for use indoors. The indoor HEMP environment depends on the electromagnetic shielding quality of a facility and the level of protection against the conducted environment. This standard is intended for all facility types including residential, commercial, light industrial, hospitals, heavy industrial, power substations and power generation facilities. This standard includes indoor equipment intended to be connected to a low-voltage (1 kV or less) power network, to the telecom network and/or to external antennas. Immunity test values are based on the 90 % severity levels in IEC 61000-4-25. All telecom lines are assumed to have gas-tube protectors at the point where they enter the building and insulation flashover on low-voltage lines are assumed at three times that of lightning. For signal ports connected to internal cables, severity test levels are based on cables that have a total length of 10 m and a procedure is provided for longer cables. This part of IEC 61000 does not specify safety requirements for equipment, such as protection against shock, insulation coordination, and related dielectric tests. Nevertheless, the immunity tests described in this part of IEC 61000 involve hazardous voltages. High-voltage precautions are necessary to protect the health and safety of test personnel.

Committee
TC 77/SC 77C
DevelopmentNote
Stability date: 2018. (11/2017)
DocumentType
Standard
Pages
39
PublisherName
International Electrotechnical Committee
Status
Current

05/30136204 DC : DRAFT JUL 2005
IEC TS 61000-5-8:2009 Electromagnetic compatibility (EMC) - Part 5-8: Installation and mitigation guidelines - HEMP protection methods for the distributed infrastructure
BS IEC 62003:2009 Nuclear power plants. Instrumentation and control important to safety. Requirements for electromagnetic compatibility testing
PD IEC/TS 61000-5-10:2017 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. Guidance on the protection of facilities against HEMP and IEMI
I.S. EN 61000-4-18:2007 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
IEC TS 61000-5-9:2009 Electromagnetic compatibility (EMC) - Part 5-9: Installation and mitigation guidelines - System-level susceptibility assessments for HEMP and HPEM
IEC 61000-4-18:2006+AMD1:2010 CSV Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test
08/30181498 DC : DRAFT APR 2008 BS EN 61000-5-8 - ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 5-8: INSTALLATION AND MITIGATION GUIDELINES - HEMP PROTECTION METHODS FOR THE DISTRIBUTED INFRASTRUCTURE
DD IEC/TS 61000-5-9:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. System-level susceptibility assessments for HEMP and HPEM
DD IEC/TS 61000-5-8:2009 Electromagnetic compatibility (EMC) Installation and mitigation guidelines. HEMP protection methods for the distributed infrastructure
NF EN 61000-4-18 : 2007 AMD 1 2011 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
BS EN 61000-4-18 : 2007 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-18: TESTING AND MEASUREMENT TECHNIQUES - DAMPED OSCILLATORY WAVE IMMUNITY TEST
16/30316578 DC : 0 BS EN ISO 13766-1 - EARTH-MOVING- AND BUILDING CONSTRUCTION MACHINERY - ELECTROMAGNETIC COMPATIBILITY OF MACHINES WITH INTERNAL ELECTRICAL POWER SUPPLY - PART 1: GENERAL EMC REQUIREMENTS UNDER TYPICAL EMC ENVIRONMENTAL CONDITIONS
IEEE 1642-2015 IEEE Recommended Practice for Protecting Publicly Accessible Computer Systems from Intentional Electromagnetic Interference (IEMI)
CEI EN 50090-9-1 : 2005 HOME AND BUILDING ELECTRONIC SYSTEMS (HBES) - PART 9-1: INSTALLATION REQUIREMENTS - GENERIC CABLING FOR HBES CLASS 1 TWISTED PAIR
IEC TS 61000-5-10:2017 Electromagnetic compatibility (EMC) - Part 5-10: Installation and mitigation guidelines - Guidance on the protection of facilities against HEMP and IEMI
CAN/CSA-IEC 61000-4-18:14 (R2018) Electromagnetic compatibility (EMC) - Part 4-18: Testing and measurement techniques - Damped oscillatory wave immunity test (Adopted IEC 61000-4-18:2011, edition 1:2006 consolidated with amendment 1:2010) | Compatibilité électromagnétique (CEM) - Partie 4-18 : Techniques d\'essai et de mesure - Essai d\'immunité à l\'onde oscillatoire amortie (norme CEI 61000-4-18:2011 adoptée, édition 1:2006 consolidée par l\'amendement 1:2010)
IEC 62003:2009 Nuclear power plants - Instrumentation and control important to safety - Requirements for electromagnetic compatibility testing

IEC TR 61000-5-3:1999 Electromagnetic compatibility (EMC) - Part 5-3: Installation and mitigation guidelines - HEMP protection concepts
IEC 61024-1:1990 Protection of structures against lightning - Part 1: General principles
IEC 61000-2-10:1998 Electromagnetic compatibility (EMC) - Part 2-10: Environment - Description of HEMP environment - Conducted disturbance
IEC 60068-1:2013 Environmental testing - Part 1: General and guidance
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST
IEC 61000-2-11:1999 Electromagnetic compatibility (EMC) - Part 2-11: Environment - Classification of HEMP environments
IEC 61000-6-2:2016 Electromagnetic compatibility (EMC) - Part 6-2: Generic standards - Immunity standard for industrial environments
IEC 61000-4-11:2004+AMD1:2017 CSV Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests
IEC 61000-4-25:2001+AMD1:2012 CSV Electromagnetic compatibility (EMC) - Part 4-25: Testing and measurement techniques - HEMP immunity test methods for equipment and systems
IEC 61000-4-4:2012 RLV Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test
IEC 61643-21:2000+AMD1:2008+AMD2:2012 CSV Low voltage surge protective devices - Part 21: Surge protective devices connected to telecommunications and signalling networks - Performance requirements and testing methods
IEC TS 61000-6-5:2001 Electromagnetic compatibility (EMC) - Part 6-5: Generic standards - Immunity for power station and substation environments
IEC 61000-4-20:2010 Electromagnetic compatibility (EMC) - Part 4-20: Testing and measurement techniques - Emission and immunity testing in transverse electromagnetic (TEM) waveguides
IEC 61000-4-2:2008 Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test
ISO 7137:1995 Aircraft — Environmental conditions and test procedures for airborne equipment
IEC 61000-2-9:1996 Electromagnetic compatibility (EMC) - Part 2: Environment - Section 9: Description of HEMP environment - Radiated disturbance. Basic EMC publication
IEC 61000-6-2 : 3.0:2016 ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 6-2: GENERIC STANDARDS - IMMUNITY STANDARD FOR INDUSTRIAL ENVIRONMENTS
IEC 61000-4-13:2002+AMD1:2009+AMD2:2015 CSV Electromagnetic compatibility (EMC) - Part 4-13: Testing and measurement techniques - Harmonics and interharmonics includingmains signalling at a.c. power port, low frequency immunity tests

View more information
US$133.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.