• There are no items in your cart

IEC 61847:1998

Current
Current

The latest, up-to-date edition.

Ultrasonics - Surgical systems - Measurement and declaration of the basic output characteristics
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Language(s)

English, Spanish, Castilian

Published date

01-30-1998

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Definitions
4 List of symbols
5 General measurement requirements
    5.1 Operating conditions
    5.2 Load conditions
    5.3 Preparation for measurements
6 Measurement procedures
    6.1 Primary tip vibration excursion
    6.2 Secondary tip vibration excursion
    6.3 Drive frequency
    6.4 Tip vibration frequency
    6.5 Derived output acoustic power and output
          acoustic power
    6.6 Directivity pattern
    6.7 Primary tip vibration excursion modulation
    6.8 Duty cycle
    6.9 Quiescent electrical power
    6.10 Maximum electrical power
    6.11 Primary acoustic output area
    6.12 Secondary acoustic output area
    6.13 Power reserve index
7 Declaration of output characteristics
Figures
Annexes
A Measurement methods and conditions
B Theory of operation of ultrasonic surgical devices
C Bibliography

This standard specifies: - the essential non-thermal output characteristics of ultrasonic surgical units; - methods of measurement ot these output characteristics; - those characteristics which should be declared by the manufacturers of such equipment. This standard is applicable to equipment which meets the requirements of a, b and c below: a) ultrasonic surgical systems operating in the frequency range 20 kHz to 60 kHz; and b) ultrasonic surgical systems, whose use is the fragmentation or cutting of human tissue, whether or not those effects are delivered in conjunction with tissue removal or coagulation; and c) ultrasonic surgical systems, in which an acoustic wave is conducted by means of a specifically designed wave guide to deliver energy to the surgical site.

Committee
TC 87
DevelopmentNote
Also numbered as BS EN 61847. (09/2005) Stability Date: 2018. (09/2017)
DocumentType
Standard
Pages
31
PublisherName
International Electrotechnical Committee
Status
Current

Standards Relationship
NEN EN IEC 61847 : 1998 Identical
PN EN 61847 : 2002 Identical
AS/NZS 4512:1999 Identical
CEI EN 61847 : 1999 Identical
EN 61847:1998 Identical
DIN EN 61847:1998-09 Similar to
UNE-EN 61847:2000 Identical

NF EN 80601-2-58:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL DEVICES AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
BS EN 62127-1 : 2007 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ
NF EN 62127-1 : 2008 AMD 1 2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ
EN 80601-2-58:2015 Medical electrical equipment - Part 2-58: Particular requirements for the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery
ANSI/AAMI/IEC 80601-2-58:2014 MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
ISO 16142-1:2016 Medical devices — Recognized essential principles of safety and performance of medical devices — Part 1: General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
BS ISO 16142-1:2016 Medical devices. Recognized essential principles of safety and performance of medical devices General essential principles and additional specific essential principles for all non-IVD medical devices and guidance on the selection of standards
BS EN 80601-2-58:2015 Medical electrical equipment Particular requirements for the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery
IEC 62127-1:2007+AMD1:2013 CSV Ultrasonics - Hydrophones - Part 1: Measurement and characterizationof medical ultrasonic fields up to 40 MHz
IEC 80601-2-58:2014+AMD1:2016 CSV Medical electrical equipment - Part 2-58: Particular requirementsfor the basic safety and essential performance of lens removal devices and vitrectomy devices for ophthalmic surgery
13/30271473 DC : 0 BS EN 80601-2-58 - MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL DEVICES AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
CSA C22.2 No. 80601-2-58 : 2010 MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL DEVICES AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
I.S. EN 80601-2-58:2015 MEDICAL ELECTRICAL EQUIPMENT - PART 2-58: PARTICULAR REQUIREMENTS FOR THE BASIC SAFETY AND ESSENTIAL PERFORMANCE OF LENS REMOVAL DEVICES AND VITRECTOMY DEVICES FOR OPHTHALMIC SURGERY
I.S. EN 62127-1:2007 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007 (EQV))
EN 62127-1:2007/A1:2013 ULTRASONICS - HYDROPHONES - PART 1: MEASUREMENT AND CHARACTERIZATION OF MEDICAL ULTRASONIC FIELDS UP TO 40 MHZ (IEC 62127-1:2007/A1:2013)

IEC 60500:2017 Underwater acoustics - Hydrophones - Properties of hydrophones in the frequency range 1 Hz to 500 kHz
IEC 61205:1993 Ultrasonics - Dental descaler systems - Measurement and declaration of the output characteristics

View more information
US$273.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.