• There are no items in your cart

IEC 62013-1:2005

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Caplights for use in mines susceptible to firedamp - Part 1: General requirements - Construction and testing in relation to the risk of explosion
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-26-2011

Language(s)

English - French, Spanish, Castilian

Published date

10-24-2005

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 General
   4.1 Enclosures
   4.2 Internal electrical connections
   4.3 Solid electrical insulating
   4.4 Internal wiring
   4.5 Surface temperature
   4.6 Supply of electrical power to another apparatus
   4.7 Creepage and clearance distances
   4.8 Assembled electrical connection
5 Overcurrent protection
6 Headpiece
7 Battery
8 Cable
9 External charging contacts
10 Type verifications and tests
   10.1 General
   10.2 Impact test
   10.3 Drop tests
   10.4 Test to verify the protection against ingress
         of dust and water
   10.5 Test to verify the non-ignition of a
         representative electrolytic gas mixture or
         firedamp by fuse or thermal circuit-breaker
   10.6 Test to verify the non-ignition of a gas mixture
         by one strand of the cable between the headpiece
         and the battery by thermal ignition
   10.7 Test to verify the resistance of the cable sheath
         to fatty acids
   10.8 Test to verify the resistance of the cable sheath
         to fire
   10.9 Test to verify the strength of cable entries,
         anchoring devices and cable
   10.10 Spark ignition test
   10.11 Electrolyte leakage test
   10.12 Current-limiting resistor test
11 Marking
12 Instructions

This part of IEC 62013 specifies requirements for the construction and testing of caplights, including caplights with a point of connection for another apparatus, for use in mines susceptible to firedamp (Group I - electrical apparatus for explosive gas atmospheres as defined in IEC 60079-0). It deals only with the risk of the caplight becoming a source of ignition.

Committee
TC 31
DocumentType
Standard
Pages
33
PublisherName
International Electrotechnical Committee
Status
Superseded
SupersededBy
Supersedes

Standards Relationship
NEN EN IEC 62013-1 : 2006 Identical
PN EN 62013-1 : 2008 Identical
SN EN 62013-1 : 2006 Identical
VDE 0170-14-1 : 2012 Identical
EN 62013-1:2006 Identical
DIN EN 62013-1 : 2007 Identical
CEI EN 62013-1 : 2007 Identical
I.S. EN 62013-1:2006 Identical
UNE-EN 62013-1:2007 Identical
BS EN 62013-1:2006 Identical

CSA C22.2 No. 60079.0 : 2015 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
IEC 60079-7:2015+AMD1:2017 CSV Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
EN IEC 60079-7:2015/A1:2018 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015/A1:2017)
EN 62013-2:2006 Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
03/300201 DC : DRAFT FEB 2003 IEC 60079-0 ED.4.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
03/313427 DC : DRAFT NOV 2003 IEC 62013-2 - CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - PART 2: PERFORMANCE AND OTHER SAFETY-RELATED MATTERS
04/30113660 DC : DRAFT MAY 2004 IEC 60079-7 - ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY 'E'
BS EN 60079-7 : 2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E' (IEC 60079-7:2015)
CSA C22.2 No. 60079-7 : 2016 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
09/30206527 DC : 0 BS EN 60079-0 ED 6.0 - EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
BIS IS/IEC 60079-0 : 2011 EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
I.S. EN 60079-11:2012 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
ISA 60079-7 : 2008 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY "E"
14/30278882 DC : 0 BS EN 60079-7 IEC 60079-7 ED. 5.0 - EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 62013-2:2006 CAPLIGHTS FOR USE IN MINES SUSCEPTIBLE TO FIREDAMP - PART 2: PERFORMANCE AND OTHER SAFETY-RELATED MATTERS
IEC 60079-11:2011 RLV Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 62013-2:2005 Caplights for use in mines susceptible to firedamp - Part 2: Performance and other safety-related matters
IEC 60079-11 REDLINE : 6.0 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
UNE-EN 60079-11:2013 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
PD CEN/TR 16149:2011 Guidance Document for drafting CEN/TC 158 Standards
BS EN 62013-2:2006 Caplights for use in mines susceptible to firedamp Performance and other safety-related matters
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
BS EN 60079-11:2012 Explosive atmospheres Equipment protection by intrinsic safety \'i\'
UNE-EN 60079-0:2013 Explosive atmospheres - Part 0: Equipment - General requirements
05/30134569 DC : DRAFT JUN 2005 IEC 60079-0. ED. 5.0 - ELECTRICAL APPARATUS FOR EXPLOSIVE ATMOSPHERES - PART 0: GENERAL REQUIREMENTS
I.S. EN 60079-0:2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011 (MOD))
CSA E60079.7 : 2003 ELECTRICAL APPARATUS FOR EXPLOSIVE GAS ATMOSPHERES - PART 7: INCREASED SAFETY "E"
BIS IS/IEC 60079-7 : 2006 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
I.S. EN 60079-7:2015 EXPLOSIVE ATMOSPHERES - PART 7: EQUIPMENT PROTECTION BY INCREASED SAFETY 'E'
BS EN 60079-0 : 2012 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS
UNE-EN 60079-7:2016 Explosive atmospheres - Part 7: Equipment protection by increased safety "e"
CSA C22.2 No. 60079-11 : 2014 EXPLOSIVE ATMOSPHERES - PART 11: EQUIPMENT PROTECTION BY INTRINSIC SAFETY 'I'
EN 60079-0:2012/A11:2013 EXPLOSIVE ATMOSPHERES - PART 0: EQUIPMENT - GENERAL REQUIREMENTS (IEC 60079-0:2011, MODIFIED)
CEN/TR 16149:2011 Guidance Document for drafting CEN/TC 158 Standards
EN 60079-11:2012 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"

IEC 60079-1:2014 RLV Explosive atmospheres - Part 1: Equipment protection by flameproof enclosures "d"
IEC TR 60079-20:1996 Electrical apparatus for explosive gas atmospheres - Part 20: Data for flammable gases and vapours, relating to the use of electrical apparatus
IEC 60332-1:1993 Tests on electric cables under fire conditions - Part 1: Test on a single vertical insulated wire or cable
IEC 60050-845:1987 International Electrotechnical Vocabulary (IEV) - Part 845: Lighting
IEC 60127-2:2014 Miniature fuses - Part 2: Cartridge fuse-links
IEC 60079-11:2011 Explosive atmospheres - Part 11: Equipment protection by intrinsic safety "i"
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV Degrees of protection provided by enclosures (IP Code)
IEC 60079-0:2011 Explosive atmospheres - Part 0: Equipment - General requirements

View more information
US$133.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.