• There are no items in your cart

IEC TR 62271-303:2008

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

High-voltage switchgear and controlgear - Part 303: Use and handling of sulphur hexafluoride (SF6)
Available format(s)

Hardcopy , PDF

Superseded date

08-26-2013

Language(s)

English - French

Published date

07-23-2008

FOREWORD
INTRODUCTION
1 Scope
2 Normative references
3 Terms and definitions
4 Storage and transportation of SF[6]
   4.1 Storage of containers filled with SF[6]
   4.2 Transportation of containers filled with SF[6]
   4.3 Storage and transportation of electric power equipment
        containing SF[6]
   4.4 Responsibilities
5 Safety and first aid
   5.1 General safety rules
        5.1.1 Protection of personnel
        5.1.2 Handling of contaminated safety equipment and
               tools
        5.1.3 Pressurised equipment and tools or measuring
               devices
        5.1.4 Personal safety and protective equipment
        5.1.5 Facilities and services
   5.2 Additional safety measures in case of abnormal release
        of SF[6] due to external fire or internal arc fault
   5.3 First aid equipment and treatment
        5.3.1 Irritation of the skin
        5.3.2 Irritation of the eyes
        5.3.3 Breathing difficulty
6 Training and certification
   6.1 General
   6.2 Training modules
        6.2.1 Module A - Awareness
        6.2.2 Module B1 - Maintenance not implying gas
               recovery
        6.2.3 Module B2 - Installation and commissioning
        6.2.4 Module C1 - Maintenance implying gas recovery
        6.2.5 Module C2 - Decommissioning of electric power
               equipment at the end-of-life
   6.3 Certification
7 SF[6] handling during installation and commissioning
   7.1 Evacuation, filling and checking the SF[6] quality after
        filling
   7.2 Topping-up of SF[6] pre-filled compartments to the rated
        pressure/density
   7.3 Filling sealed pressure systems
8 SF[6] handling during normal service life
   8.1 Re-filling of SF[6] to the nominal pressure/density
   8.2 Checking the SF[6] quality
        8.2.1 Measurement of the SF[6] quality with portable
               equipment
        8.2.2 Sampling and shipment of SF[6] for off-site
               analysis
9 SF[6] recovering and reclaiming during maintenance
   9.1 Recovery and reclaiming of SF[6] from any compartment
        of controlled and/or closed pressure systems containing
        non-arced and/or normally arced SF[6]
   9.2 Recovery and reclaiming from any compartment of
        controlled and/or closed pressure systems containing
        heavily arced SF[6]
10 Dismantling of SF[6] electric power equipment at the
   end-of-life
   10.1 End-of-life of controlled and/or closed pressure systems
   10.2 End-of-life of sealed pressure systems
   10.3 Recovery and reclaiming of SF[6] at the end-of-life of
        sealed pressure systems
   10.4 Dismantling of electric power equipment at the
        end-of-life
   10.5 By-products at the end-of-life
11 Description of SF[6] handling equipment
   11.1 Reclaimer
        11.1.1 External and internal pre-filters
        11.1.2 Filters
        11.1.3 Vacuum pump
        11.1.4 Main and auxiliary compressors
        11.1.5 External and internal gas storage containers
        11.1.6 Evaporator and gas storage container heater
        11.1.7 Gas piping and pipe junctions
        11.1.8 Control instruments
        11.1.9 Safety valves
   11.2 Flexible hose connections
   11.3 Portable devices for gas measurement
        11.3.1 Dew point meter
        11.3.2 SF[6] percentage measuring device
        11.3.3 Reaction tubes sensitive to SO[2]
        11.3.4 Portable SF[6] detectors
        11.3.5 Alarm system SF[6] detectors
   11.4 Cylinder for gas samples
Annex A (informative) Sulphur hexafluoride
Annex B (informative) Environmental effects of SF[6]
Annex C (informative) SF[6] by-products
Annex D (informative) Potential effects on health of SF[6]
        by-products
Bibliography

IEC/TR 62271-303:2008 addresses the procedures for safe and environmental compatible handling of SF6 during installation, commissioning, normal and abnormal operations, disposal at the end of life of high voltage switchgear and controlgear. Storage and transportation of SF6 are also covered. These procedures should be regarded as minimum requirements to ensure the safety of personnel working with SF6 and to minimize the SF6 emission to the environment. This first edition of IEC/TR 62271-303 cancels and replaces the first edition of IEC 61634 published in 1995. This edition constitutes a technical revision. This edition includes the following significant technical changes with respect to the previous edition: IEC/TR 62271-303 is a major revision of the old IEC 61634. The former sections of IEC 61634 are removed and replaced by the chapters of the CIGRE brochure n. 276. IEC 61634 was issued in 1995 when the focus was on safety. In 2008, safety is a very well known and established concept and the focus is nowadays on the environmental compatibility. SF6 must be kept in a closed cycle and any intentional release must be forbidden. The implementation of the SF6 reuse concept suggested in the CIGRE brochure was updated with the most recent information. Today SF6 can be recovered and reclaimed for either being reused on-site or given back to the gas supplier and reused as raw material for the production of "technical grade SF6". Detailed procedures for appropriate SF6 handling are given together with the description of the state-of-the-art equipments and measuring devices.

DevelopmentNote
Supersedes IEC 61634. (07/2008) Stability Date: 2012. (10/2012)
DocumentType
Technical Report
Pages
160
PublisherName
International Electrotechnical Committee
Status
Superseded

I.S. EN 61936-1:2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES
BS EN 61936-1 : 2010 POWER INSTALLATIONS EXCEEDING 1 KV A.C - PART 1: COMMON RULES
EN 62271-109:2009/A1:2013 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008/A1:2013)
EN 61936-1 : 2010 AMD 1 2014 POWER INSTALLATIONS EXCEEDING 1 KV A.C. - PART 1: COMMON RULES (IEC 61936-1:2010/A1:2014)
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
IEC 62271-109:2008+AMD1:2013 CSV High-voltage switchgear and controlgear - Part 109: Alternating-current series capacitor by-pass switches
IEC 61936-1:2010+AMD1:2014 CSV Power installations exceeding 1 kV a.c. - Part 1: Common rules
BIS IS/IEC 62271-109 : 2008 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES
NEMA SG 11 : 2013 GUIDE FOR HANDLING AND MAINTENANCE OF ALTERNATING CURRENT OUTDOOR HIGH-VOLTAGE CIRCUIT BREAKERS
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
UNE-EN 62271-203:2013 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
BS EN 62271-204:2011 High-voltage switchgear and controlgear Rigid gas-insulated transmission lines for rated voltage above 52 kV
I.S. EN 62271-109:2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES (IEC 62271-109:2008 (EQV))
BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
BS EN 62271-109 : 2009 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 109: ALTERNATING-CURRENT SERIES CAPACITOR BY-PASS SWITCHES
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
I.S. EN 62271-200:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV))
BS EN 62271-203:2012 High-voltage switchgear and controlgear Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
EN 62271-204:2011 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
UNE-EN 62271-204:2012 High-voltage switchgear and controlgear - Part 204: Rigid gas-insulated transmission lines for rated voltage above 52 kV
IEEE C37.10-2011 REDLINE IEEE Guide for Investigation, Analysis, and Reporting of Power Circuit Breaker Failures
UNE-EN 62271-200:2012 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
UNE-EN 61936-1:2012 Power installations exceeding 1 kV a.c. -- Part 1: Common rules
EN 62271-203:2012 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
BS IEC/IEEE 62271-37-013:2015 High-voltage switchgear and controlgear Alternating-current generator circuit-breakers

IEC 60480:2004 Guidelines for the checking and treatment of sulfur hexafluoride (SF<sub>6</sub>) taken from electrical equipment and specification for its re-use
IEC 62271-100:2008+AMD1:2012+AMD2:2017 CSV High-voltage switchgear and controlgear - Part 100: Alternating-current circuit-breakers
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 60050-601:1985 International Electrotechnical Vocabulary (IEV) - Part 601: Generation, transmission and distribution of electricity - General
IEC 60050-441:1984 International Electrotechnical Vocabulary (IEV) - Part 441: Switchgear, controlgear and fuses
IEC 60376:2005 Specification of technical grade sulfur hexafluoride (SF<sub>6</sub>) for use in electrical equipment
IEC 62271-203:2011 High-voltage switchgear and controlgear - Part 203: Gas-insulated metal-enclosed switchgear for rated voltages above 52 kV
IEC 62271-1:2017 High-voltage switchgear and controlgear - Part 1: Common specifications for alternating current switchgear and controlgear
IEC 60695-7-1:2010 Fire hazard testing - Part 7-1: Toxicity of fire effluent - General guidance
AS 2791-1996 High-voltage switchgear and controlgear - Use and handling of sulphur hexafluoride (SF6) in high-voltage switchgear and controlgear
ISO 14040:2006 Environmental management Life cycle assessment Principles and framework

View more information
US$400.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.