IEC TS 62257-3:2015
Current
The latest, up-to-date edition.
Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users
English
12-11-2015
IEC TS 62257-3:2015(E) provides information on the responsibilities involved in the implementation of rural power systems. More particularly it covers:
- contractual relationships to be built between the different participants to a project;
- the relevant tests to be applied to renewable energy and hybrid electrification systems;
- quality assurance principles to be implemented;
- requirements for recycling and protection of the environment. The main technical changes with regard to the previous edition are as follows:
- redefine the maximum AC voltage from 500 V to 1 000 V, the maximum DC voltage from 750 V to 1 500 V;
- removal of the limitation of 100 kVA system size.
This publication is to be read in conjunction with IEC 62257 series.
DevelopmentNote |
Partially supersedes IEC PAS 62111. (11/2004) To be read in conjunction with IEC TS 62257 (ALL PARTS). Stability Date: 2018. (12/2015)
|
DocumentType |
Technical Specification
|
Pages |
48
|
PublisherName |
International Electrotechnical Committee
|
Status |
Current
|
Supersedes |
Standards | Relationship |
PD IEC/TS 62257-3:2015 | Identical |
NEN NVN IEC/TS 62257-3 : 2015 | Identical |
SANS ARP 062-3 : 1ED 2006 | Identical |
DD IEC TS 62257-3 : DRAFT 2004 | Identical |
05/30134580 DC : DRAFT JUN 2005 | IEC 62257-9-4 - RECOMMENDATIONS FOR SMALLL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 9-4: INTEGRATED SYSTEM - USER'S INSTALLATION |
05/30134574 DC : DRAFT JUNE 2005 | |
DD IEC TS 62257-4 : DRAFT 2005 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 4: SYSTEM SELECTION AND DESIGN |
IEC TS 62257-9-1:2016 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 9-1: Integrated systems - Micropower systems |
PD IEC/TS 61836:2016 | Solar photovoltaic energy systems. Terms, definitions and symbols |
DD IEC TS 62257-5 : DRAFT 2005 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 5: PROTECTION AGAINST ELECTRICAL HAZARDS |
DD IEC TS 61836 : 2007 COR 2011 | SOLAR PHOTOVOLTAIC ENERGY SYSTEMS - TERMS, DEFINITIONS AND SYMBOLS |
DD CLC/TS 61836:2009 | Solar photovoltaic energy systems. Terms, definitions and symbols |
S.R. CLC/TS 61836:2009 | SOLAR PHOTOVOLTAIC ENERGY SYSTEMS - TERMS, DEFINITIONS AND SYMBOLS |
IEC TS 62257-1:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 1: General introduction to IEC 62257 series and rural electrification |
IEC TS 61836 REDLINE : 3ED 2016 | SOLAR PHOTOVOLTAIC ENERGY SYSTEMS - TERMS, DEFINITIONS AND SYMBOLS |
PD IEC/TS 62257-4:2015 | Recommendations for renewable energy and hybrid systems for rural electrification System selection and design |
IEC TS 62257-7-1:2010 | Recommendations for small renewable energy and hybrid systems for rural electrification - Part 7-1: Generators - Photovoltaic generators |
IEC TS 61836:2016 RLV | Solar photovoltaic energy systems - Terms, definitions and symbols |
PD IEC/TS 62257-9-1:2016 | Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems. Micropower systems |
06/30152485 DC : DRAFT JUL 2006 | BS IEC 62257-12-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 12-1: SELECTION OF INTEGRAL COMPACT FLUORESCENT LAMPS FOR RURAL ELECTRIFICATION SYSTEMS AND RECOMMENDATIONS FOR HOUSEHOLD LIGHTING EQUIPMENT |
PD IEC/TS 62257-9-5:2016 | Recommendations for renewable energy and hybrid systems for rural electrification Integrated systems. Selection of stand-alone lighting kits for rural electrification |
CLC/TS 61836:2009 | Solar photovoltaic energy systems - Terms, definitions and symbols |
IEC TS 62257-5:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 5: Protection against electrical hazards |
IEC TS 61836:2007 | Solar photovoltaic energy systems - Terms, definitions and symbols |
CEI CLC/TS 61836 : 2012 | SOLAR PHOTOVOLTAIC ENERGY SYSTEMS - TERMS, DEFINITIONS AND SYMBOLS |
07/30168230 DC : 0 | BS EN 62257-9-1 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 9-1: MICROPOWER SYSTEMS |
DD IEC TS 62257-9-1 : DRAFT 2008 | RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 9-1: MICROPOWER SYSTEMS |
PD IEC/TS 62257-6:2015 | Recommendations for renewable energy and hybrid systems for rural electrification Acceptance, operation, maintenance and replacement |
05/30134577 DC : DRAFT JUNE 2005 | IEC 62257-9-3 - RECOMMENDATIONS FOR SMALL RENEWABLE ENERGY AND HYBRID SYSTEMS FOR RURAL ELECTRIFICATION - PART 9-3: INTEGRATED SYSTEM - USER'S INTERFACE |
PD IEC/TS 62257-1:2015 | Recommendations for renewable energy and hybrid systems for rural electrification General introduction to IEC 62257 series and rural electrification |
IEC TS 62257-6:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 6: Acceptance, operation, maintenance and replacement |
IEC TS 62257-4:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 4: System selection and design |
PD IEC/TS 62257-5:2015 | Recommendations for renewable energy and hybrid systems for rural electrification Protection against electrical hazards |
IEC 60060-2:2010 | High-voltage test techniques - Part 2: Measuring systems |
IEC 60721-1:1990+AMD1:1992+AMD2:1995 CSV | Classification of environmental conditions - Part 1: Environmental parameters and their severities |
IEC 60068-2-5:2010 | Environmental testing - Part 2-5: Tests - Test Sa: Simulated solar radiation at ground level and guidance for solar radiation testing |
IEC 60068-1:2013 | Environmental testing - Part 1: General and guidance |
IEC 61000-4-4 : 3.0EN+(REDLINE+VERSION) | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 4-4: TESTING AND MEASUREMENT TECHNIQUES - ELECTRICAL FAST TRANSIENT/BURST IMMUNITY TEST |
IEC 60068-2-27:2008 | Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock |
IEC 61000-4-1:2006 | Electromagnetic compatibility (EMC) - Part 4-1: Testing and measurement techniques - Overview of IEC 61000-4 series |
IEC 61000-4-11:2004+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 4-11: Testing and measurement techniques - Voltage dips, short interruptions and voltage variations immunity tests |
IEC 60076-10:2016 | Power transformers - Part 10: Determination of sound levels |
IEC 61000-4-4:2012 RLV | Electromagnetic compatibility (EMC) - Part 4-4: Testing and measurement techniques - Electrical fast transient/burst immunity test |
IEC 60068-2-31:2008 | Environmental testing - Part 2-31: Tests - Test Ec: Rough handling shocks, primarily for equipment-type specimens |
CISPR 22:2008 | Information technology equipment - Radio disturbance characteristics - Limits and methods of measurement |
IEC 60721-2-1:2013 | Classification of environmental conditions - Part 2-1: Environmental conditions appearing in nature - Temperature and humidity |
IEC 61000-6-3:2006+AMD1:2010 CSV | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments |
IEC 60364-6:2016 | Low voltage electrical installations - Part 6: Verification |
IEC 60695-2-12:2010+AMD1:2014 CSV | Fire hazard testing - Part 2-12: Glowing/hot-wire based test methods- Glow-wire flammability index (GWFI) test method for materials |
IEC TS 62257-5:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 5: Protection against electrical hazards |
IEC 60529:1989+AMD1:1999+AMD2:2013 CSV | Degrees of protection provided by enclosures (IP Code) |
IEC 60068-2-10:2005 | Environmental testing - Part 2-10: Tests - Test J and guidance: Mould growth |
IEC 60721-3-2:1997 | Classification of environmental conditions - Part 3: Classification of groups of environmental parameters and their severities - Section 2: Transportation |
IEC 60068-2-2:2007 | Environmental testing - Part 2-2: Tests - Test B: Dry heat |
IEC 61000-4-2:2008 | Electromagnetic compatibility (EMC) - Part 4-2: Testing and measurement techniques - Electrostatic discharge immunity test |
IEC 61000-4-3:2006+AMD1:2007+AMD2:2010 CSV | Electromagnetic compatibility (EMC) - Part 4-3: Testing and measurement techniques - Radiated, radio-frequency, electromagnetic field immunity test |
IEC 62262:2002 | Degrees of protection provided by enclosures for electrical equipment against external mechanical impacts (IK code) |
IEC 61000-2-2:2002+AMD1:2017 CSV | Electromagnetic compatibility (EMC) - Part 2-2: Environment - Compatibility levels for low-frequency conducted disturbances and signalling in public low-voltage power supply systems |
IEC 60721-3-3:1994+AMD1:1995+AMD2:1996 CSV | Classification of environmental conditions - Part 3-3: Classification of groups of environmental parameters and their severities - Stationary use at weatherprotected locations |
IEC 60068-2-75:2014 | Environmental testing - Part 2-75: Tests - Test Eh: Hammer tests |
IEC 60068-2-1:2007 | Environmental testing - Part 2-1: Tests - Test A: Cold |
IEC TS 62257-2:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 2: From requirements to a range of electrification systems |
IEC 61180-1:1992 | High-voltage test techniques for low voltage equipment - Part 1: Definitions, test and procedure requirements |
IEC 61140:2016 | Protection against electric shock - Common aspects for installation and equipment |
IEC 60695-2-10:2013 | Fire hazard testing - Part 2-10: Glowing/hot-wire based test methods - Glow-wire apparatus and common test procedure |
IEC 60068-2-52:2017 | Environmental testing - Part 2-52: Tests - Test Kb: Salt mist, cyclic (sodium chloride solution) |
IEC TS 62257-6:2015 | Recommendations for renewable energy and hybrid systems for rural electrification - Part 6: Acceptance, operation, maintenance and replacement |
IEC 60721-3-1:1997 | Classification of environmental conditions - Part 3 Classification of groups of environmental parameters and their severities - Section 1: Storage |
IEC 61000-3-2 : 4.0 | ELECTROMAGNETIC COMPATIBILITY (EMC) - PART 3-2: LIMITS - LIMITS FOR HARMONIC CURRENT EMISSIONS (EQUIPMENT INPUT CURRENT <= 16 A PER PHASE) |
IEC 60068-2-30:2005 | Environmental testing - Part 2-30: Tests - Test Db: Damp heat, cyclic (12 h + 12 h cycle) |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.