1 Overview
  1.1 Scope
  1.2 Purpose
2 Normative references
3 Definitions
4 Maintenance inspections and tests
  4.1 Safety for inspections and tests
  4.2 Maintenance inspections
  4.3 Maintenance tests
5 Determination and investigation of failure occurrence
  5.1 Following a suspected failure
  5.2 Investigation flow chart
  5.3 Data collection
6 Failure analysis
  6.1 Common symptoms and causes
  6.2 Stator failures
  6.3 Rotor failure modes
  6.4 Shaft failures
  6.5 Lubrication and bearing failure modes
  6.6 Structures
  6.7 Ventilation
  6.8 Accessories
Annex A (informative) Bibliography
Annex B (informative) Suggested checklists
Annex C (informative) Failure investigation test methods

Presents maintenance testing and failure analysis guidance for form-wound, squirrel cage, induction machinery rated up to 15 kV.

DevelopmentNote
Supersedes IEEE DRAFT 1415. (10/2007)
DocumentType
Standard
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn

CSA C392 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : INC : UPD 2 : 2012 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : INC : UPD 1 : 2011 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT
CSA C392 : 2011 : R2016 TESTING OF THREE-PHASE SQUIRREL CAGE INDUCTION MOTORS DURING REFURBISHMENT

NEMA MG 1 : 2016 MOTORS AND GENERATORS
NEMA MG 2:2014 Safety Standard for Construction and Guide for Selection, Installation and Use of Electric Motors and Generators
NEMA MG 10:2017 Energy Management Guide for Selection and Use of Fixed Frequency Medium AC Squirrel-Cage Polyphase Induction Motors
IEEE 841-2009 IEEE Standard for Petroleum and Chemical Industry--Premium-Efficiency, Severe-Duty, Totally Enclosed Fan-Cooled (TEFC) Squirrel Cage Induction Motors--Up to and Including 370 kW (500 hp)
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
IEEE 389-1996 IEEE Recommended Practice for Testing Electronics Transformers and Inductors
IEEE 95-2002 IEEE Recommended Practice for Insulation Testing of AC Electric Machinery (2300 V and Above) With High Direct Voltage
ASTM E 1444 : 2005 Standard Practice for Magnetic Particle Testing
IEEE 1434-2014 IEEE Guide for the Measurement of Partial Discharges in AC Electric Machinery
ANSI/NEMA C50.41 : 2012 POLYPHASE INDUCTION MOTORS FOR POWER GENERATION STATIONS
API STD 541 : 2014 FORM-WOUND SQUIRREL CAGE INDUCTION MOTORS - 375 KW (500 HORSEPOWER) AND LARGER
IEEE 1068-2015 REDLINE IEEE Standard for the Repair and Rewinding of AC Electric Motors in the Petroleum, Chemical, and Process Industries
IEEE 43-2013 IEEE Recommended Practice for Testing Insulation Resistance of Electric Machinery
IEEE 112-2004 IEEE Standard Test Procedure for Polyphase Induction Motors and Generators
IEEE 286-2000 IEEE Recommended Practice for Measurement of Power Factor Tip-Up of Electric Machinery Stator Coil Insulation

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.