• There are no items in your cart

IEEE 1590-2009 REDLINE

Current
Current

The latest, up-to-date edition.

IEEE Recommended Practice for the Electrical Protection of Communication Facilities Serving Electric Supply Locations Using Optical Fiber Systems
Available format(s)

PDF

Language(s)

English

Published date

06-26-2009

1. Overview
   1.1 Scope
   1.2 Purpose
   1.3 Not covered
2. Normative references
3. Definitions
4. Abbreviations and acronyms
5. Overview of telecommunications service to electric
   supply locations
   5.1 Service via metallic wire-line facilities
   5.2 Service via fiber optic facilities
   5.3 Service via microwave systems
   5.4 Wireless site owners' responsibilities
6. Service types, reliability, service performance
   objective (SPO) classifications, and transmission
   considerations (from Clause 6 of IEEE Std 487-2007)
   6.1 Service types
   6.2 SPO classifications
   6.3 Transmission considerations
7. Powering arrangements at electric supply locations
   7.1 Typical ac power service to wireless locations
        at power line towers or poles
   7.2 Distribution transformers
   7.3 Electric field induction
   7.4 Emergency engine generating units
8. Telecommunications service to electric supply
   locations
   8.1 Wireless sites at electric supply locations
   8.2 Wireless sites within zone of influence (ZOI)
   8.3 Locations at, or near, high-voltage towers or poles
   8.4 Electrical protection considerations for
        telecommunications outside plant serving high-voltage
        tower and pole sites
   8.5 Electrical protection measures
   8.6 Typical grounding
9. Telecommunications service to electric supply
   locations - recommendations
   9.1 GPR-related protection considerations
   9.2 Induction-related protection considerations
   9.3 Benefits of all-dielectric cables
10. Construction concerns and general recommendations
    10.1 Existing facilities
11. Location of CFJ
    11.1 Electric power station
    11.2 Wireless sites
12. Typical dc powering arrangements at OEI and CFJ
    12.1 Wire-line-fiber cable junction (CFJ)
    12.2 Remote end and OEI
13. Installation and inspection considerations
    13.1 Installation considerations
    13.2 Periodic considerations
14. Safety
    14.1 General safety considerations
    14.2 Electrical safety
    14.3 Radio frequency (RF) safety awareness
Annex A (informative) - Bibliography
Annex B (informative) - GPR and ZOI profiles
Annex C (informative) - Service request data

Specifies engineering design procedures for the electrical protection of communication facilities serving electric supply locations using optical fiber systems. Services utilizing wire-line protection systems are addressed in IEEE Std 487-2007.

Committee
Power System Communications and Cybersecurity
DocumentType
Standard
ISBN
978-0-7381-5964-5
Pages
50
PublisherName
Institute of Electrical & Electronics Engineers
Status
Current
SupersededBy
Supersedes

IEEE 1222-2011 IEEE Standard for Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines
IEEE DRAFT 525 : D15 2006 DESIGN AND INSTALLATION OF CABLE SYSTEMS IN SUBSTATIONS
IEEE 1185-2010 IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities
IEEE 1615-2007 IEEE Recommended Practice for Network Communication in Electric Power Substations
IEEE 1692-2011 IEEE Guide for the Protection of Communication Installations from Lightning Effects

IEEE C37.90-2005 IEEE Standard for Relays and Relay Systems Associated with Electric Power Apparatus
IEEE 80-2000 IEEE Guide for Safety in AC Substation Grounding
IEEE 487-2015 IEEE Standard for the Electrical Protection of Communications Facilities Serving Electric Supply Locations -- General Considerations
IEEE 81-2012 IEEE Guide for Measuring Earth Resistivity, Ground Impedance, and Earth Surface Potentials of a Grounding System
IEEE 487-2007 IEEE Recommended Practice for the Protection of Wire-Line Communication Facilities Serving Electric Supply Locations
IEEE 1222-2011 IEEE Standard for Testing and Performance for All-Dielectric Self-Supporting (ADSS) Fiber Optic Cable for Use on Electric Utility Power Lines
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C57.12.90-2010 IEEE Standard Test Code for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE C37.90.3-2001 IEEE Standard Electrostatic Discharge Tests for Protective Relays
IEEE 80-2013 REDLINE IEEE Guide for Safety in AC Substation Grounding
IEEE C2-2017 NATIONAL ELECTRICAL SAFETY CODE (NESC)(R)
IEEE 367-1996 IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault
NFPA 70 : 2017 NATIONAL ELECTRICAL CODE
IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
IEEE 789-2013 IEEE Standard Performance Requirements for Communications and Control Cables for Application in High-Voltage Environments
IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
IEEE 1243:1997 GUIDE FOR IMPROVING THE LIGHTNING PERFORMANCE OF TRANSMISSION LINES
ATIS T1.316 : 2002 ELECTRICAL PROTECTION OF TELECOMMUNICATIONS OUTSIDE PLANT
IEEE 367-2012 IEEE Recommended Practice for Determining the Electric Power Station Ground Potential Rise and Induced Voltage from a Power Fault

View more information
US$175.82
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.