1. Overview
2. Normative references
3. Definitions, acronyms, and abbreviations
4. Safety
5. Very low frequency (VLF) ac testing
6. Conclusions
Annex A (informative) - Bibliography
Annex B (normative) - Wave shapes of VLF ac voltage
        testing voltages
Annex C (informative) - Typical defects in fluid-filled
        and extruded cable systems
Annex D (informative) - Effect of initial increase in
        voltage (ramp up)
Annex E (informative) - Figures of merit and range of
        available tangent delta and differential tangent
        delta (tip up) data
Annex F (informative) - Comments on data interpretation
        and performance
Annex G (informative) - Tan delta results of new cable
        systems
Annex H (informative) - Development of utility/application
        specific criteria
Annex I (informative) - Tangent delta criteria used outside
        North America

Specifies VLF withstand and other diagnostic tests and the measurements that are performed in the field on service-aged shielded medium and high-voltage cables rated 5 kV through 69 kV with extruded and laminated insulation.

Committee
Insulated Conductors
DevelopmentNote
Supersedes IEEE DRAFT 400.2. (03/2005) Also included in IEEE 400 Set (CD-ROM) dated 28/11/2012 with IEEE 400, IEEE 400.1 and IEEE 400.3. Also included in IEEE 400 Series dated 05/10//2013 with IEEE 400, IEEE 400.1 and IEEE 400.3. (10/2013)
DocumentType
Standard
ISBN
978-0-7381-8422-7
Pages
111
PublisherName
Institute of Electrical & Electronics Engineers
Status
Current
Supersedes

IEEE 1242-1999 IEEE Guide for Specifying and Selecting Power, Control, and Special-Purpose Cable for Petroleum and Chemical Plants
BS EN 62271-200:2012 High-voltage switchgear and controlgear AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
CSA C293.2 : 2017 STANDARD FOR SKIN EFFECT TRACE HEATING OF PIPELINES, VESSELS, EQUIPMENT, AND STRUCTURES - APPLICATION GUIDE FOR DESIGN, INSTALLATION, TESTING, COMMISSIONING, AND MAINTENANCE
NFPA 70B : 2016 RECOMMENDED PRACTICE FOR ELECTRICAL EQUIPMENT MAINTENANCE
EN 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
EN 60505:2011/AC:2017-03 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS (IEC 60505:2011/COR1:2017)
IEEE 844.2/CSA C293.2-2017 IEEE/CSA Standard for Skin Effect Trace Heating of Pipelines, Vessels, Equipment, and Structures--Application Guide for Design, Installation, Testing, Commissioning, and Maintenance
I.S. EN 60505:2011 EVALUATION AND QUALIFICATION OF ELECTRICAL INSULATION SYSTEMS
NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
CEI EN 62271-201 : 2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
UNE-EN 62271-200:2012 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
12/30253935 DC : DRAFT JUNE 2012 BS EN 62271-201 - HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - AC SOLID-INSULATED ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above
IEEE 3007.2 : 2010 This recommended practice covers the maintenance of industrial and commercial power systems.
I.S. EN 62271-200:2012 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: A.C. METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011 (EQV))
EN 62271-200:2012/AC:2015 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 200: AC METAL-ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV (IEC 62271-200:2011)
IEC 62271-111:2012 High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
IEEE/IEC C37.60-2012 IEEE/IEC International Standard - High-voltage switchgear and controlgear - Part 111: Automatic circuit reclosers and fault interrupters for alternating current systems up to 38 kV
BS EN 60505:2011 Evaluation and qualification of electrical insulation systems
IEEE 1205-2014 IEEE Guide for Assessing, Monitoring, and Mitigating Aging Effects on Electrical Equipment Used in Nuclear Power Generating Stations and Other Nuclear Facilities
UNE-EN 62271-201:2015 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 60505:2011 Evaluation and qualification of electrical insulation systems
IEEE 1185-2010 IEEE Recommended Practice for Cable Installation in Generating Stations and Industrial Facilities
IEEE 400.4-2015 IEEE Guide for Field Testing of Shielded Power Cable Systems Rated 5 kV and Above with Damped Alternating Current (DAC) Voltage
BS EN 62271-201:2014 High-voltage switchgear and controlgear AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEEE 422-2012 IEEE Guide for the Design of Cable Raceway Systems for Electric Generating Facilities
IEEE C37.63-2013 REDLINE IEEE Standard Requirements for Overhead, Pad-Mounted, Dry-Vault, and Submersible Automatic Line Sectionalizers for Alternating Current Systems Up to 38 kV
IEEE 2030.2-2015 IEEE Guide for the Interoperability of Energy Storage Systems Integrated with the Electric Power Infrastructure
I.S. EN 62271-201:2014 HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 201: AC SOLID-INSULATION ENCLOSED SWITCHGEAR AND CONTROLGEAR FOR RATED VOLTAGES ABOVE 1 KV AND UP TO AND INCLUDING 52 KV
IEC 62271-201:2014 High-voltage switchgear and controlgear - Part 201: AC solid-insulation enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEC 62271-200:2011 High-voltage switchgear and controlgear - Part 200: AC metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV
IEEE 400.3-2022 IEEE Guide for Partial Discharge Field Diagnostic Testing of Shielded Power Cable Systems

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
NETA ATS : 2017 ACCEPTANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
IEC 60885-3:2015 RLV Electrical test methods for electric cables - Part 3: Test methods for partial discharge measurements on lengths of extruded power cables
NETA MTS : 2011 MAINTENANCE TESTING SPECIFICATIONS FOR ELECTRICAL POWER EQUIPMENT AND SYSTEMS
IEEE 1617:2007 DETECTION, MITIGATION, AND CONTROL OF CONCENTRIC NEUTRAL CORROSION IN MEDIUM-VOLTAGE UNDERGROUND CABLES
NFPA 70E : 2018 ELECTRICAL SAFETY IN THE WORKPLACE
IEC 60060-3:1976 High-voltage test techniques - Part 3: Measuring devices
IEC 61230:2008 Live working - Portable equipment for earthing or earthing and short-circuiting
IEEE 400-2012 REDLINE IEEE Guide for Field Testing and Evaluation of the Insulation of Shielded Power Cable Systems Rated 5 kV and Above

View more information
US$174.64
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.