• There are no items in your cart

IEEE C57.13.5-2009

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

IEEE Standard of Performance and Test Requirements for Instrument Transformers of a Nominal System Voltage of 115 kV and Above
Available format(s)

PDF

Superseded date

02-04-2022

Language(s)

English

Published date

12-30-2009

1. Overview
2. Normative references
3. Definitions
4. General
5. Test conditions
6. Classification of test
7. Routine test procedures (applicable to instrument
    transformers)
8. Routine test procedures (applicable to current
    transformers)
9. Routine test procedures (applicable to voltage
    transformers)
10. Type test procedures (applicable to instrument
    transformers)
11. Type test procedure (applicable to current
    transformers)
12. Special test procedures
13. Identification of test sample in the type test
    report
Annex A (normative) - Test code
Annex B (informative) - Dielectric test performed at
        an altitude of 1000 m or less for instrument
        transformers designed for installation at
        altitudes greater than 1000 m
Annex C (informative) - Dielectric tests, oil sampling,
        and other related measurements in the field
Annex D (informative) - Internal arc protection for
        instrument transformers
Annex E (normative) - Validity of type test reports
        and guidance for reviewing the design comparison
        report for the modified design
Annex F (informative) - Rated voltage factor
Annex G (normative) - Current transformers used for the
        detection of unbalance current of capacitor banks
Annex H (informative) - Current transformers having
        transient performance requirements
Annex I (informative) - Electrical endurance test,
        explanatory note
Annex J (informative) - Bibliography

Pertains to single-phase instrument transformers of a nominal system voltage of 115 kV and above with capacitive insulation system for line-to-ground connection and for both indoor and outdoor application.

Committee
Transformers
DocumentType
Standard
ISBN
978-0-7381-6086-3
Pages
77
PublisherName
Institute of Electrical & Electronics Engineers
Status
Superseded
SupersededBy
Supersedes

CSA C60044-5:2007 INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS
CSA C60044-5 : 2007 : R2011 INSTRUMENT TRANSFORMERS - PART 5: CAPACITOR VOLTAGE TRANSFORMERS
IEEE 1601-2010 IEEE Trial-Use Standard for Optical AC Current and Voltage Sensing Systems
CSA C60044-1 : 2007 : R2011 INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS
CSA C60044-1 : 2007 INSTRUMENT TRANSFORMERS - PART 1: CURRENT TRANSFORMERS
IEEE 1861-2014 IEEE Guide for On-Site Acceptance Tests of Electrical Equipment and System Commissioning of 1000 kV AC and Above
IEEE C57.13-2016 IEEE Standard Requirements for Instrument Transformers
IEEE C37.241-2017 IEEE Guide for Application of Optical Instrument Transformers for Protective Relaying

IEC 60270:2000+AMD1:2015 CSV High-voltage test techniques - Partial discharge measurements
IEEE C57.19.100-2012 REDLINE IEEE Guide for Application of Power Apparatus Bushings
EN 50052:2016 High-voltage switchgear and controlgear - Gas-filled cast aluminium alloy enclosures
IEEE 4-1995 IEEE Standard Techniques for High-Voltage Testing
NEMA 107:2016 Methods of Measurement of Radio Influence Voltage (RIV) of High Voltage Apparatus
IEEE C57.19.01-2000 IEEE Standard Performance Characteristics and Dimensions for Outdoor Apparatus Bushings
EN 50064 : 1989 COR 2007 WROUGHT ALUMINIUM AND ALUMINIUM ALLOY ENCLOSURES FOR GAS-FILLED HIGH-VOLTAGE SWITCHGEAR AND CONTROLGEAR
ASTM D 1275 : 2015 Standard Test Method for Corrosive Sulfur in Electrical Insulating Liquids
IEEE 4-2013 IEEE Standard for High-Voltage Testing Techniques
IEEE C62.11-2005 IEEE Standard for Metal-Oxide Surge Arresters for AC Power Circuits (> 1 kV)
IEC 60044-6:1992 Instrument transformers - Part 6: Requirements for protective current transformers for transient performance
ASTM D 1868 : 2013 : REDLINE Standard Test Method for Detection and Measurement of Partial Discharge (Corona) Pulses in Evaluation of Insulation Systems
IEC 61181:2007+AMD1:2012 CSV Mineral oil-filled electrical equipment - Application of dissolved gas analysis (DGA) to factory tests on electrical equipment
EN 50068 : 1991 COR 2007 WROUGHT STEEL ENCLOSURES FOR GAS FILLED HIGH VOLTAGE SWITCHGEAR AND CONTROLGEAR
IEEE C57.13-2008 IEEE Standard Requirements for Instrument Transformers
IEEE 693-2005 IEEE Recommended Practice for Seismic Design of Substations
IEEE C57.106-2006 IEEE Guide for Acceptance and Maintenance of Insulating Oil in Equipment

View more information
US$105.73
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.