SEISMIC DESIGN OF SUBSTATIONS

Withdrawn date

10-17-2023

Published date

01-12-2013

1 Overview
  1.1 Scope
  1.2 Purpose
  1.3 How to use this recommended practice
  1.4 Acceptance of previously qualified electrical equipment
  1.5 Earthquakes and substations
  1.6 Design and construction
  1.7 The equipment at risk
  1.8 Mechanical loads
2 References
3 Definitions
4 Abbreviations and acronyms
5 Instructions
  5.1 General
  5.2 Specifying this recommended practice in user's specifications
  5.3 Standardization of criteria
  5.4 Selection of qualification level
  5.5 Witnessing of shake-table testing
  5.6 Optional qualification methods
  5.7 Qualifying equipment by group
  5.8 Inherently acceptable equipment
  5.9 Shake-table facilities
  5.10 Equipment too large to be tested in their in-service
       configuration
  5.11 Report templates
  5.12 Web site
6 Installation considerations
  6.1 General
  6.2 Equipment assembly
  6.3 Site response characteristic
  6.4 Soil-structure interaction
  6.5 Support structures
  6.6 Base isolation
  6.7 Suspended equipment
  6.8 Anchorage
  6.9 Conductor induced loading
  6.10 Short Circuit Loads
  6.11 Wind and Ice Loads
7 Qualification methods: An overview
  7.1 General
  7.2 Analysis methods
  7.3 Testing methods
  7.4 Special Test cases
  7.5 Qualification methods for specific equipment
  7.6 Functionality of equipment
  7.7 Qualification by seismic experience data
  7.8 Response Spectra
  7.9 Damping
8 Design considerations
  8.1 Structural Supports, excluding foundations
  8.2 Foundation analysis
  8.3 Station service
  8.4 Emergency power systems
  8.5 Telecommunication equipment
9 Seismic performance criteria for electrical substation equipment
  9.1 Introduction
  9.2 Objective
  9.3 Seismic qualification levels
  9.4 Projected performance
  9.5 Seismic qualification
  9.6 Selecting the seismic level for seismic qualification
Annex A (normative) Standard clauses
Annex B (normative) Equipment, general
Annex C (normative) Circuit breakers
Annex D (normative) Transformers and liquid filled reactors
Annex E (normative) Disconnect and grounding switches
Annex F (normative) Instrument transformers
Annex G (normative) Air core reactors
Annex H (normative) Circuit switchers
Annex I (normative) Suspended equipment
Annex J (normative) Station batteries and battery racks
Annex K (normative) Surge arresters
Annex L (normative) Substation electronic devices, distribution
        panels and switchboards, and solid-state rectifiers
Annex M (normative) Metalclad switchgear
Annex N (normative) Cable terminators (potheads)
Annex O (normative) Capacitors, series and shunt compensation
Annex P (normative) Gas-insulated switchgear
Annex Q (normative) Experienced based qualification procedures
        for low-voltage substation equipment
Annex R (informative) Composite and porcelain insulators
Annex S (normative) Analysis report template
Annex T (normative) Test report template
Annex U (informative) Specifications
Annex V (informative) Bibliography

Presents recommendations for the seismic design of substation buildings, structures, and equipment.

DocumentType
Draft
PublisherName
Institute of Electrical & Electronics Engineers
Status
Withdrawn
SupersededBy

IEEE C37.32-2002 American National Standard for High Voltage Switches, Bus Supports, and Accessories Schedules of Preferred Ratings, Construction Guidelines, and Specifications
AS 4435.4-2005 Insulators - Composite for overhead power lines - Voltages greater than 1000 V a.c. Definitions, test methods, acceptance criteria for post insulator units (Reconfirmed 2016)
IEEE C37.20.2-2015 IEEE Standard for Metal-Clad Switchgear
IEC 61109:2008 Insulators for overhead lines - Composite suspension and tension insulators for a.c. systems with a nominal voltage greater than 1 000 V - Definitions, test methods and acceptance criteria
IEC 60672-3:1997 Ceramic and glass-insulating materials - Part 3: Specifications for individual materials
IEEE C57.12.00-2015 IEEE Standard for General Requirements for Liquid-Immersed Distribution, Power, and Regulating Transformers
IEEE 344-2013 IEEE Standard for Seismic Qualification of Equipment for Nuclear Power Generating Stations
IEEE 1527-2006 IEEE Recommended Practice for the Design of Flexible Buswork Located in Seismically Active Areas
IEEE 1036-2010 IEEE Guide for the Application of Shunt Power Capacitors
IEC 60129:1984 Alternating current disconnectors and earthing switches
IEEE C37.20.3-2013 REDLINE IEEE Standard for Metal-Enclosed Interrupter Switchgear (1 kV-38 kV)
NEMA SG 4:2009(R2013) ALTERNATING CURRENT HIGH-VOLTAGE CIRCUIT BREAKERS
IEEE 484-2002 IEEE Recommended Practice for Installation Design and Installation of Vented Lead-Acid Batteries for Stationary Applications
IEEE C37.90.2:2004 WITHSTAND CAPABILITY OF RELAY SYSTEMS TO RADIATED ELECTROMAGNETIC INTERFERENCE FROM TRANSCEIVERS
IEEE C37.06-2009 AC HIGH-VOLTAGE CIRCUIT BREAKERS RATED ON A SYMMETRICAL CURRENT BASIS - PREFERRED RATINGS AND RELATED REQUIRED CAPABILITIES
IEEE C37.09-1999 IEEE Standard Test Procedure for AC High-Voltage Circuit Breakers Rated on a Symmetrical Current Basis
IEEE 1133-1988 IEEE Application Guide for Evaluating Nonceramic Materials for High-Voltage Outdoor Applications
IEEE C37.90.1-2012 IEEE Standard for Surge Withstand Capability (SWC) Tests for Relays and Relay Systems Associated with Electric Power Apparatus
ANSI/NEMA C93.1-1999 American National Standard for Requirements for Power-Line Carrier Coupling Capacitors and Coupling Capacitor Voltage Transformers (CCVTs)
IEEE C57.21 : 2008 REQUIREMENTS, TERMINOLOGY, AND TEST CODE FOR SHUNT REACTORS RATED OVER 500 KVA
AWS D1.1 : 2000 STRUCTURAL WELDING CODE - STEEL

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.