• There are no items in your cart

ISO 12219-1:2012

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Interior air of road vehicles Part 1: Whole vehicle test chamber Specification and method for the determination of volatile organic compounds in cabin interiors
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

08-31-2021

Language(s)

English, French

Published date

07-10-2012

ISO 12219-1:2012 describes and specifies the whole vehicle test chamber, the vapour sampling assembly and the operating conditions for the determination of volatile organic compounds (VOCs), and carbonyl compounds in vehicle cabin air. There are three measurements performed: one (for VOCs and carbonyl compounds) during the simulation of ambient conditions (ambient mode) at standard conditions of 23 C with no air exchange; a second only for the measurement of formaldehyde at elevated temperatures (parking mode); and a third for VOCs and carbonyl compounds simulating driving after the vehicle has been parked in the sun starting at elevated temperatures (driving mode). For the simulation of the mean sun irradiation, a fixed irradiation in the whole vehicle test chamber is employed.

The VOC method is valid for measurement of non-polar and slightly polar VOCs in a concentration range of sub-micrograms per cubic metre up to several milligrams per cubic metre. Using the principles described in this method, some semi-volatile organic compounds (SVOC) can also be analysed. Compatible compounds are those which can be trapped and released from the Tenax TA[1] sorbent tubes described in ISO 160006, which includes VOCs ranging in volatility from n-C6 to n-C16.

The sampling and analysis procedure for formaldehyde and other carbonyl compounds is performed by collecting air on to cartridges coated with 2,4-dinitrophenylhydrazine (DNPH) and subsequent analysis by high performance liquid chromatography (HPLC) with detection by ultraviolet absorption. Formaldehyde and other carbonyl compounds can be determined in the approximate concentration range 1 g/m3 to 1 mg/m3.

The method is valid for passenger cars, as defined in ISO 3833.

ISO 12219-1:2012 describes: a) transport and storage of the test vehicles until the start of the test; b) conditioning for the surroundings of the test vehicle and the test vehicle itself as well as the whole vehicle test chamber; c) conditioning of the test vehicle prior to measurements; d) simulation of ambient air conditions (ambient mode); e) formaldehyde sampling at elevated temperatures (parking mode); f) simulation of driving after the test vehicle has been parked in the sun (driving mode).

Buses, motor caravans, and trucks, in accordance with the descriptions given in ISO 3833, are excluded.

[1] Tenax TA is the trade name of a product supplied by Buchem. This information is given for the convenience of users of this document and does not constitute an endorsement by ISO of the product named. Equivalent products may be used if they can be shown to lead to the same results.

DevelopmentNote
Supersedes ISO/DIS 12219-1. (07/2012)
DocumentType
Standard
Pages
22
PublisherName
International Organization for Standardization
Status
Withdrawn
SupersededBy

Standards Relationship
DIN ISO 12219-1:2013-12 Identical
GOST R ISO 12219-1 : 2014 Identical
NEN ISO 12219-1 : 2012 Identical
BS ISO 12219-1:2012 Identical
NF ISO 12219-1 : 2012 Identical

DIN ISO 16000-6:2012-11 Indoor air - Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA? sorbent, thermal desorption and gas chromatography using MS or MS-FID (ISO 16000-6:2011)
BS ISO 16000-16:2008 Indoor air Detection and enumeration of moulds. Sampling by filtration
BS ISO 16000-29:2014 Indoor air Test methods for VOC detectors
DIN ISO 12219-3:2013-12 Interior air of road vehicles - Part 3: Screening method for the determination of the emissions of volatile organic compounds from vehicle interior parts and materials - Micro-scale chamber method (ISO 12219-3:2012)
ASTM D 8141 : 2017 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
DIN ISO 16000-3 E : 2013 INDOOR AIR - PART 3: DETERMINATION OF FORMALDEHYDE AND OTHER CARBONYL COMPOUNDS IN INDOOR AIR AND TEST CHAMBER AIR
DIN ISO 16000-3:2013-01 Indoor air - Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air - Active sampling method (ISO 16000-3:2011)
DIN ISO 16000-17:2010-06 Indoor air - Part 17: Detection and enumeration of moulds - Culture-based method (ISO 16000-17:2008)
ISO 12219-7:2017 Interior air of road vehicles Part 7: Odour determination in interior air of road vehicles and test chamber air of trim components by olfactory measurements
DIN ISO 16000-13:2010-03 Indoor air - Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Collection on sorbent-backed filters (ISO 16000-13:2008)
DIN ISO 16000-18:2012-01 Indoor air - Part 18: Detection and enumeration of moulds - Sampling by impaction (ISO 16000-18:2011 + Cor.1:2011)
DIN ISO 16000-6 E : 2012 INDOOR AIR - PART 6: DETERMINATION OF VOLATILE ORGANIC COMPOUNDS IN INDOOR AND TEST CHAMBER AIR BY ACTIVE SAMPLING ON TENAX TA[R] SORBENT, THERMAL DESORPTION AND GAS CHROMATOGRAPHY USING MS OR MS-FID (ISO 16000-6:2011)
15/30273463 DC : 0 BS ISO 12219-7 - INTERIOR AIR OF ROAD VEHICLES - PART 7: ODOUR DETERMINATION IN INTERIOR AIR OF ROAD VEHICLES AND TEST CHAMBER AIR OF TRIM COMPONENTS BY OLFACTORY MEASUREMENTS
BS ISO 16000-17:2008 Indoor air Detection and enumeration of moulds. Culture-based method
BS ISO 16000-14:2009 Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
ISO 16000-13:2008 Indoor air — Part 13: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) — Collection on sorbent-backed filters
ISO 16000-17:2008 Indoor air — Part 17: Detection and enumeration of moulds — Culture-based method
ISO 16000-16:2008 Indoor air — Part 16: Detection and enumeration of moulds — Sampling by filtration
DIN ISO 16000-29:2015-02 INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014)
BS ISO 12219-7:2017 Interior air of road vehicles Odour determination in interior air of road vehicles and test chamber air of trim components by olfactory measurements
BS ISO 16000-13:2008 Indoor air Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs). Collection on sorbent-backed filters
DIN ISO 16000-29 E : 2015 INDOOR AIR - PART 29: TEST METHODS FOR VOC DETECTORS (ISO 16000-29:2014)
DIN ISO 16000-16:2009-12 Indoor air - Part 16: Detection and enumeration of moulds - Sampling by filtration (ISO 16000-16:2008)
DIN ISO 16000-14:2012-03 Indoor air - Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) - Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry (ISO 16000-14:2009)
ISO 16000-14:2009 Indoor air Part 14: Determination of total (gas and particle-phase) polychlorinated dioxin-like biphenyls (PCBs) and polychlorinated dibenzo-p-dioxins/dibenzofurans (PCDDs/PCDFs) Extraction, clean-up and analysis by high-resolution gas chromatography and mass spectrometry
ISO 16000-29:2014 Indoor air Part 29: Test methods for VOC detectors

JASO Z 125 : 2009 GENERAL AND OTHERS - ROAD VEHICLES - INTERIOR - MEASUREMENT METHODS OF DIFFUSED VOLATILE ORGANIC COMPOUNDS (VOC)
ISO 16000-25:2011 Indoor air Part 25: Determination of the emission of semi-volatile organic compounds by building products Micro-chamber method
ISO 16000-5:2007 Indoor air Part 5: Sampling strategy for volatile organic compounds (VOCs)
ISO 9060:1990 Solar energy Specification and classification of instruments for measuring hemispherical solar and direct solar radiation
ISO 16017-1:2000 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 1: Pumped sampling
ISO 16000-24:2009 Indoor air Part 24: Performance test for evaluating the reduction of volatile organic compound (except formaldehyde) concentrations by sorptive building materials
ISO 16017-2:2003 Indoor, ambient and workplace air — Sampling and analysis of volatile organic compounds by sorbent tube/thermal desorption/capillary gas chromatography — Part 2: Diffusive sampling
ISO 3833:1977 Road vehicles — Types — Terms and definitions
ISO 16000-9:2006 Indoor air — Part 9: Determination of the emission of volatile organic compounds from building products and furnishing — Emission test chamber method
ISO 16000-3:2011 Indoor air — Part 3: Determination of formaldehyde and other carbonyl compounds in indoor air and test chamber air — Active sampling method
ISO 16000-10:2006 Indoor air Part 10: Determination of the emission of volatile organic compounds from building products and furnishing Emission test cell method
ISO 16000-11:2006 Indoor air — Part 11: Determination of the emission of volatile organic compounds from building products and furnishing — Sampling, storage of samples and preparation of test specimens
ISO 16000-6:2011 Indoor air Part 6: Determination of volatile organic compounds in indoor and test chamber air by active sampling on Tenax TA sorbent, thermal desorption and gas chromatography using MS or MS-FID

View more information
US$73.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.