• There are no items in your cart

ISO 8769:2016

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

View Superseded by
withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Reference sources Calibration of surface contamination monitors Alpha-, beta- and photon emitters
Available format(s)

Hardcopy , PDF , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

06-24-2020

Language(s)

French, English

Published date

01-04-2016

ISO 8769:2016 specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters, beta-emitters, and photon emitters of maximum photon energy not greater than 1,5 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC 60325[8], IEC 62363[9], and other documents.

NOTE Since some of the proposed photon sources include filters, the photon sources are to be regarded as sources of photons of a particular energy range and not as sources of a particular radionuclide. For example, a 241Am source with the recommended filtration does not emit from the surface the alpha particles or characteristic low-energy L X-ray photons associated with the decay of the nuclide. It is designed to be a source that emits photons with an average energy of approximately 60 keV.

ISO 8769:2016 also specifies preferred reference radiations for the calibration of surface contamination monitors. These reference radiations are realized in the form of adequately characterized large area sources specified, without exception, in terms of surface emission rates which are traceable to national standards.

DevelopmentNote
Supersedes ISO 8769-2. (09/2010) Supersedes ISO/DIS 8769. (01/2016)
DocumentType
Standard
Pages
15
PublisherName
International Organization for Standardization
Status
Withdrawn
SupersededBy
Supersedes

Standards Relationship
BS ISO 8769:2010 Identical
NEN ISO 8769 : 2016 Identical
NF ISO 8769 : 2016 Identical
IS 16693 : 2021 Identical
VDE 0412-8769 : 2016 Identical
DIN ISO 8769 : 2016 Identical
NF ISO 8769:2022 Identical
BS ISO 8769:2016 Identical
PN ISO 8769 : 2005 Identical

BS ISO 7503-1:2016 Measurement of radioactivity. Measurement and evaluation of surface contamination General principles
00/715261 DC : DRAFT DEC 2000 IEC 60325 - ALPHA, BETA AND ALPHA-BETA CONTAMINATION METERS AND MONITORS
IEEE/ANSI N323B-2003 American National Standard for Radiation Protection Instrumentation Test and Calibration, Portable Survey Instrumentation for Near Background Operation
14/30274825 DC : 0 BS ISO 7503-2 - MEASUREMENT OF RADIOACTIVITY - MEASUREMENT AND E EVALUATION OF SURFACE CONTAMINATION - PART 2: TEST METHOD USING WIPE-TEST SAMPLES
ASTM E 2216 : 2002 : R2013 Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning
IEEE N323C-2009 American National Standard Radiation Protection Instrumentation Test and Calibration - Air Monitoring Instruments
ASTM E 1893 : 2015 : REDLINE Standard Guide for Selection and Use of Portable Radiological Survey Instruments for Performing In Situ Radiological Assessments to Support Unrestricted Release from Further Regulatory Controls
NF EN 61098 : 2008 RADIATION PROTECTION INSTRUMENTATION - INSTALLED PERSONNEL SURFACE CONTAMINATION MONITORING ASSEMBLIES
BS IEC 60325:2002 Radiation protection instrumentation. Alpha, beta and alpha/beta (beta energy > 60 keV) contamination meters and monitors
ISO 7503-1:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles
BS EN 60325:2004 Radiation protection instrumentation. Alpha, beta and alpha/beta (beta energy > 60 keV) contamination meters and monitors
I.S. EN 60325:2004 RADIATION PROTECTION INSTRUMENTATION - ALPHA, BETA AND ALPHA/BETA (BETA ENERGY > 60 KEV) CONTAMINATION METERS AND MONITORS
IEEE/ANSI N323AB-2013 American National Standard for Radiation Protection Instrumentation Test and Calibration, Portable Survey Instruments
ISO 7503-3:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 3: Apparatus calibration
ASTM E 2216 : 2002 : R2008 Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning
I.S. EN 61098:2007 RADIATION PROTECTION INSTRUMENTATION - INSTALLED PERSONNEL SURFACE CONTAMINATION MONITORING ASSEMBLIES
IEC 62089:2001 Nuclear instrumentation - Calibration and usage of alpha/beta gas proportional counters
IEC 61098:2003 Radiation protection instrumentation - Installed personnel surface contamination monitoring assemblies
BS ISO 7503-3:2016 Measurement of radioactivity. Measurement and evaluation of surface contamination Apparatus calibration
BS EN 61098:2007 Radiation protection instrumentation. Installed personnel surface contamination monitoring assemblies
IEEE N323D-2002 American National Standard for Installed Radiation Protection Instrumentation
CEI EN 60325 : 2005 RADIATION PROTECTION INSTRUMENTATION - ALPHA, BETA AND ALPHA/BETA (BETA ENERGY > 60 KEV) CONTAMINATION METERS AND MONITORS
14/30265645 DC : 0 BS ISO 7503-3 - MEASUREMENT OF RADIOACTIVITY - MEASUREMENT AND EVALUATION OF SURFACE CONTAMINATION - PART 3: APPARATUS CALIBRATION
CEI EN 61098 : 2008 RADIATION PROTECTION INSTRUMENTATION - INSTALLED PERSONNEL SURFACE CONTAMINATION MONITORING ASSEMBLIES
14/30274840 DC : 0 BS ISO 7503-1 - MEASUREMENT OF RADIOACTIVITY - MEASUREMENT AND EVALUATION OF SURFACE CONTAMINATION - PART 1: GENERAL PRINCIPLES
IEC 61256:1996 Radiation protection instrumentation - Installed monitors for the detection of radioactive contamination of laundry
NF EN 60325 : 2004 RADIATION PROTECTION INSTRUMENTATION - ALPHA, BETA AND ALPHA/BETA (BETA ENERGY > 60 KEV) CONTAMINATION METERS AND MONITORS
DEFSTAN 05-55(PT3)/2(2016) : 2016 MEASUREMENT AND CALIBRATION SYSTEM REQUIREMENTS FOR MINISTRY OF DEFENCE TEST AND MEASUREMENT EQUIPMENT - PART 3: SUB CONTRACT OF CALIBRATION
IEEE/ANSI N323A-1997 American National Standard Radiation Protection Instrumentation Test and Calibration, Portable Survey Instruments
IEC 60325:2002 Radiation protection instrumentation - Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors
BS ISO 7503-2:2016 Measurement of radioactivity. Measurement and evaluation of surface contamination Test method using wipe-test samples
ISO 7503-2:2016 Measurement of radioactivity - Measurement and evaluation of surface contamination Part 2: Test method using wipe-test samples
ASTM E 2216 : 2002 Standard Guide for Evaluating Disposal Options for Concrete from Nuclear Facility Decommissioning
EN 60325:2004 Radiation protection instrumentation - Alpha, beta and alpha/beta (beta energy > 60 keV) contamination meters and monitors
EN 61098:2007 Radiation protection instrumentation - Installed personnel surface contamination monitoring assemblies

ISO 7503-2:2016 Measurement of radioactivity - Measurement and evaluation of surface contamination Part 2: Test method using wipe-test samples
ISO/IEC 17025:2005 General requirements for the competence of testing and calibration laboratories
ISO 4037-4:2004 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 4: Calibration of area and personal dosemeters in low energy X reference radiation fields
IEC 62363:2008 Radiation protection instrumentation - Portable photon contamination meters and monitors
ISO 4037-2:1997 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 2: Dosimetry for radiation protection over the energy ranges from 8 keV to 1,3 MeV and 4 MeV to 9 MeV
ISO 4037-1:1996 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 1: Radiation characteristics and production methods
ISO 7503-1:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 1: General principles
IEC 60325:2002 Radiation protection instrumentation - Alpha, beta and alpha/beta (beta energy >60 keV) contamination meters and monitors
ISO 12749-2:2013 Nuclear energy, nuclear technologies, and radiological protection — Vocabulary — Part 2: Radiological protection
ISO 4037-3:1999 X and gamma reference radiation for calibrating dosemeters and doserate meters and for determining their response as a function of photon energy Part 3: Calibration of area and personal dosemeters and the measurement of their response as a function of energy and angle of incidence
ISO 7503-3:2016 Measurement of radioactivity Measurement and evaluation of surface contamination Part 3: Apparatus calibration
ISO/IEC Guide 98-3:2008 Uncertainty of measurement — Part 3: Guide to the expression of uncertainty in measurement (GUM:1995)

View more information
US$73.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.