MIL-PRF-39016 Revision H:2017
Current
The latest, up-to-date edition.
09-13-2017
1. SCOPE
2. APPLICABLE DOCUMENTS
3. REQUIREMENTS
4. VERIFICATION
5. PACKAGING
6. NOTES
Specifies the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment.
This specification covers the general requirements for electromagnetic, hermetically sealed relays for use in electronic and communication-type equipment (see 6.1). These relays are designed to operate over the full range from low level to power switching with contact ratings up to 5 amperes alternating current (ac) or direct current (dc). The failure rate level is established at a confidence level of 90 percent for qualification and 60 percent for maintenance of qualification based on 100,000 cycles at +125°C under the rated load conditions specified herein. CAUTION: The use of any coil voltage less than the rated coil voltage will compromise the operation of the relay. CAUTION: Pick-up, hold, and dropout voltages are for test purposes only and are not to be used as design criteria. For additional application and caution information, see 6.1.
DocumentType |
Standard
|
Pages |
52
|
PublisherName |
US Military Specs/Standards/Handbooks
|
Status |
Current
|
Supersedes |
MIL-R-39016-39 Revision G:2014 | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW-LEVEL TO 3 AMPERES (400 MILLIWATTS) |
MIL-STD-1580 Revision B:2003 | DESTRUCTIVE PHYSICAL ANALYSIS FOR ELECTRONIC, ELECTROMAGNETIC, AND ELECTROMECHANICAL PARTS |
MIL-PRF-39016-14 Revision F:2016 | Relays, Electromagnetic, Established Reliability, 4PDT, Low Level To 2 Amperes (0.150-Inch Terminal Spacing) |
MIL-PRF-39016-20 Revision J:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL STD 11991 : A | GENERAL STANDARD FOR PARTS, MATERIALS, AND PROCESSES |
DSCC 85138 : D | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE, WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND REVERSE POLARITY PROTECTION |
MIL-PRF-39016-18 Revision H:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1 Ampere with Internal Diode for Coil Transient Suppression, Terminals 0.100-Inch Grid Pattern |
MIL-DTL-15103 Revision G:2015 | SALINITY INDICATING EQUIPMENT |
MIL-PRF-39016-44 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes, Terminals 0.200-Inch Grid Pattern (Sensitive, 100/125 Milliwatts, Coil Operate Power at 25 Degrees C) |
MIL-PRF-39016-7 Revision G:2004 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 1 Ampere |
MIL-HDBK-1760 Revision A:2004 | AIRCRAFT/STORE ELECTRICAL INTERCONNECTION SYSTEM |
MIL-PRF-39016-27 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-28 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 0.5 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-45 Revision F:2018 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (Latching) |
MIL-PRF-39016-30 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-37 Revision D:2014 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.150-INCH TERMINAL SPACING), WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-47 Revision C:2006 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 0.5 AMPERE (.100 D.I.P. TERMINAL SPACING) ONE-TENTH SIZE, SENSITIVE, BI-STABLE, (LATCHING) |
DSCC 84173 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
NASA MSFC STD 3012 : 2012 | ELECTRICAL, ELECTRONIC, AND ELECTROMECHANICAL (EEE) PARTS MANAGEMENT AND CONTROL REQUIREMENTS FOR MSFC SPACE FLIGHT HARDWARE |
MIL-PRF-39016-53 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression |
MIL-PRF-39016-25 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS) WITH AN INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-24 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-8 Revision J:2016 | Relays, Electromagnetic, Established Reliability, SPDT, Low Level to 0.5 Ampere (Latching) |
MIL-PRF-39016-22 Revision F:2016 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 2 AMPERES (0.200-INCH TERMINAL SPACING) COIL TRANSIENT SUPPRESSED |
MIL-PRF-39016-11 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C |
MIL-PRF-39016-26 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE 4O MILLIWATTS) WITH INTERNAL DIODES FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION |
MIL-PRF-39016-54 Revision D:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing) with Internal Diode for Coil Transient Suppression and Reverse Polarity Protection |
MIL-PRF-39016-41 Revision E:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE, TERMINALS 0.100-INCH GRID PATTERN SENSITIVE, 60 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREE C |
MIL R 39016/40 : G | RELAYS, ELECTROMAGNETIC, 4PDT, LOW LEVEL TO 2.0 AMPERES (0.100-INCH TERMINAL SPACING) |
MIL-PRF-39016-21 Revision H:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Sensitive, 60 Milliwatts) with Internal Diodes for Coil Transient Suppression and Polarity Reversal Protection |
MIL-PRF-39016-6 Revision L:2004 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.200-Inch Terminal Spacing) |
MIL-PRF-39016-15 Revision M:2014 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-13 Revision K:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 2 Amperes (0.150-Inch Terminal Spacing) |
MIL-PRF-39016-48 Revision D:2013 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 0.5 Ampere (.100 D.I.P. Terminal Spacing) One-Tenth Size, Sensitive, Monostable |
MIL-PRF-39016-36 Revision C:2006 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4PDT, Low Level to 2 Amperes (.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression and Reverse Polarity Protection |
MIL R 5757/7 : G | RELAYS, ELECTROMAGNETIC, HERMETICALLY SEALED, 4PDT, LOW LEVEL TO 2 AMPERES |
MIL-PRF-39016-23 Revision F:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL-PRF-39016-19 Revision H:2005 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION AND POLARITY REVERSAL PROTECTION, TERMINALS 0.100-INCH GRID PATTERN |
DSCC 84172 : F | RELAYS, ELECTROMAGNETIC, HIGH VIBRATION, DPDT, LOW LEVEL TO 1.0 AMPERE |
MIL-PRF-39016-29 Revision H:2017 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere (Latching) with Internal Diodes for Coil Transient Suppression |
MIL-PRF-83726 Revision H:2017 | Relays, Hybrid and Solid State, Time Delay, General Specification for |
MIL-PRF-39016-12 Revision H:2016 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (LATCHING) |
MIL-PRF-39016-35 Revision E:2017 | Relays, Electromagnetic, Established Reliability, Hermetically Sealed, 4 PDT Low Level to 2 Amperes (0.150-Inch Terminal Spacing), Latching, with Internal Diodes for Coil Transient Suppression |
MIL-PRF-39016-42 Revision E:2006 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere with Internal Diode for Coil Transient Suppression, Terminals .100-Inch Grid Pattern (Sensitive 60 Milliwatts, Coil Operate Power at 25 Degree C) |
MIL-R-39016-34 Revision F:2006 | Relays, Electromagnetic, DPDT, Low Level to 1.0 Ampere, (0.100-Inch Terminal Spacing) (No S/S Document) |
MIL-PRF-39016-16 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 60 MILLIWATTS) WITH INTERNAL DIODE FOR COIL TRANSIENT SUPPRESSION |
MIL R 39016/32 : F | RELAYS, ELECTROMAGNETIC, DPDT, LOW LEVEL TO 2 AMPERES (LATCHING) |
MIL-PRF-39016-9 Revision K:2016 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere |
MIL-PRF-39016-17 Revision J:2017 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, DPDT, LOW LEVEL TO 1 AMPERE TERMINALS 0.100-INCH GRID PATTERN |
MIL-PRF-39016-43 Revision E:2005 | Relays, Electromagnetic, Established Reliability, DPDT, Low Level to 1.0 Ampere, with Internal Diodes for Coil Transient Suppression, and Polarity Reversal Protection Terminals 0.100-Inch Grid Pattern (Sensitive, 60 Milliwatts, Coil Operate Power at 25 Degrees C) |
MIL R 5757/1 : K | RELAYS, ELECTRICAL, HERMETICALLY SEALED, 6PDT, LOW LEVEL TO 2 AMPERES |
MIL-PRF-39016-10 Revision G:2004 | RELAYS, ELECTROMAGNETIC, ESTABLISHED RELIABILITY, SPDT, LOW LEVEL TO 1.0 AMPERE (SENSITIVE, 40 MILLIWATTS, COIL OPERATE POWER AT 25 DEGREES C) |
MIL-STD-202-212 Base Document:2015 | METHOD 212, ACCELERATION |
MIL-STD-202-211 Base Document:2015 | METHOD 211, TERMINAL STRENGTH |
MIL-STD-202-302 Base Document:2015 | METHOD 302, INSULATION RESISTANCE |
MIL-STD-883 Revision K:2016 | TEST METHOD STANDARD - MICROCIRCUITS |
MIL-STD-202-210 Base Document:2015 | METHOD 210, RESISTANCE TO SOLDERING HEAT |
MIL-STD-1276 Revision H:2013 | Leads for Electronic Component Parts |
MIL-STD-202-303 Base Document:2015 | METHOD 303, DC RESISTANCE |
MIL-STD-1686 Revision C:1995 | ELECTROSTATIC DISCHARGE CONTROL PROGRAM FOR PROTECTION OF ELECTRICAL AND ELECTRONIC PARTS, ASSEMBLIES AND EQUIPMENT (EXCLUDING ELECTRICALLY INITIATED EXPLOSIVE DEVICES) |
MIL-STD-202-101 Base Document:2015 | METHOD 101, SALT ATMOSPHERE (CORROSION) |
MIL-STD-750 Revision F:2011 | TEST METHODS FOR SEMICONDUCTOR DEVICES |
MIL-STD-202-107 Base Document:2015 | METHOD 107, THERMAL SHOCK |
MIL-STD-202-301 Base Document:2015 | METHOD 301, DIELECTRIC WITHSTANDING VOLTAGE |
MIL-HDBK-338 Revision B:1998 | ELECTRONIC RELIABILITY DESIGN HANDBOOK |
IEEE 315 : 1975 | GRAPHIC SYMBOLS FOR ELECTRICAL AND ELECTRONICS DIAGRAMS (INCLUDING REFERENCE DESIGNATION LETTERS) |
MIL-STD-202-215 Base Document:2015 | METHOD 215, RESISTANCE TO SOLVENTS |
MIL-STD-790 Revision G:2011 | ESTABLISHED RELIABILITY AND HIGH RELIABILITY QUALIFIED PRODUCTS LIST (QPL) SYSTEMS FOR ELECTRICAL, ELECTRONIC, AND FIBER OPTIC PARTS SPECIFICATIONS |
MIL-HDBK-263 Revision B:1994 | ELECTROSTATIC DISCHARGE CONTROL HANDBOOK FOR PROTECTION OF ELECTRICAL & ELECTRONIC PARTS, ASSEMBLIES & EQUIPMENT |
MIL-STD-202-105 Base Document:2015 | METHOD 105, BAROMETRIC PRESSURE (REDUCED) |
MIL-STD-202-208 Base Document:2015 | METHOD 208, SOLDERABILITY |
MIL-STD-202 Revision H:2015 | ELECTRONIC AND ELECTRICAL COMPONENT PARTS |
MIL-STD-1285 Revision D:2004 | MARKING OF ELECTRICAL AND ELECTRONIC PARTS |
EIA 557 : 2006 | STATISTICAL PROCESS CONTROL SYSTEMS |
MIL-STD-202-214 Base Document:2015 | METHOD 214, RANDOM VIBRATION |
MIL-STD-690 Revision D:2005 | Failure Rate (FR) Sampling Plans and Procedures |
MIL-STD-202-312 Base Document:2015 | METHOD 312, LIFE, INTERMEDIATE CURRENT SWITCHING |
MIL-STD-202-204 Base Document:2015 | METHOD 204, VIBRATION, HIGH FREQUENCY |
MIL-STD-202-112 Base Document:2015 | METHOD 112, SEAL |
MIL-STD-202-213 Base Document:2015 | METHOD 213, SHOCK (SPECIFIED PULSE) |
MIL-STD-202-307 Base Document:2015 | METHOD 307, CONTACT RESISTANCE |
Please Login or Create an Account so you can add users to your Multi user PDF Later.
Important note : All end users must be registered with an Account prior to user licenses being assigned.
Users cannot be edited or removed once added to your Multi user PDF.
Access your standards online with a subscription
Features
-
Simple online access to standards, technical information and regulations.
-
Critical updates of standards and customisable alerts and notifications.
-
Multi-user online standards collection: secure, flexible and cost effective.