• There are no items in your cart

NF EN 62230 : 2007 AMD 1 2014

Current

Current

The latest, up-to-date edition.

ELECTRIC CABLES - SPARK-TEST METHOD

Published date

01-12-2013

INTRODUCTION
1 Scope
2 Types of voltage waveform
3 Procedure
4 Equipment
  4.1 Safety
  4.2 High voltage source
  4.3 Voltage monitoring equipment
  4.4 Fault indicator
  4.5 Electrodes
  4.6 Design of electrodes
5 Test voltages
6 Sensitivity
  6.1 AC, d.c. and h.f. voltages
  6.2 Pulsed voltages
  6.3 Method of assessment
7 Calibration
  7.1 General
  7.2 Verification frequency
Annex A (informative) Recommended minimum voltage levels
Annex B (informative) Example of an artificial fault device
Annex C (informative) Notes on the use of spark testing
                      machines
Bibliography

Specifies spark-test that is intended for the detection of defects in the insulation or sheathing layers of electric cables. For single core cables with no outer metallic layer, the general process is accepted as being equivalent to subjecting samples of those cables to a voltage test in water.

DevelopmentNote
Indice de classement: C32-022. PR NF EN 62230 May 2005. (05/2005) Supersedes NF EN 50356. (05/2008)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Current
Supersedes

Standards Relationship
BS EN 62230 : 2007 Identical
I.S. EN 62230:2007 Identical
NBN EN 62230 : 2007 AMD 1 2014 Identical
UNE-EN 62230:2007 Identical
EN 62230:2007/A1:2014 Identical
IEC 62230:2006+AMD1:2013 CSV Identical

XP C93 503 : 2010 XP MULTI-PAIR CABLES USED IN HIGH BIT RATE COMMUNICATION NETWORKS WITH BANDWIDTH UP TO 30 MHZ - DUCT AND BURIED CABLES
NF EN 61138 : 2008 CABLES FOR PORTABLE EARTHING AND SHORT-CIRCUITING EQUIPMENT
NF EN 50117-4-1 : 2008 AMD 1 2013 COAXIAL CABLES - PART 4-1: SECTIONAL SPECIFICATION FOR CABLES FOR BCT CABLING IN ACCORDANCE WITH EN 50173 - INDOOR DROP CABLES FOR SYSTEMS OPERATING AT 5 MHZ - 3000 MHZ
XP C93 531-17 : 2016 XP INDOOR COMMUNICATION CABLE - PART 17: SCREENED CABLES FOR RADIOFREQUENCY TELEVISION APPLICATIONS INCLUDING SATELLITE INTERMEDIATE BAND (DVB-S/S2) - CLASS 3 TV
XP C93 531-16 : 2016 XP INDOOR COMMUNICATION CABLE - PART 16: SCREENED CABLES FOR RADIOFREQUENCY TELEVISION APPLICATIONS INCLUDING SATELLITE INTERMEDIATE BAND (DVB-S/S2) - CLASS 2 TV
NF EN 60229 : 2008 ELECTRIC CABLES - TESTS ON EXTRUDED OVERSHEATHS WITH A SPECIAL PROTECTIVE FUNCTION
NFC 33 225 : 2014 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - AERODROME LIGHTING PRIMARY CIRCUIT CABLES - RATED VOLTAGE U[0]/U(UM) = 6/10(12) KV
NFC 33 224 : 2014 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - AERODROME LIGHTING PRIMARY CIRCUIT CABLES - RATED VOLTAGE U[0]/U(UM) = 3,6/6(7,2) KV
XP C93 504 : 2010 XP MULTI-PAIR CABLES USED IN HIGH BIT RATE COMMUNICATION NETWORKS WITH BANDWIDTH UP TO 30 MHZ - INDOOR AND OUTDOOR RISER CABLES

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.