• There are no items in your cart

NFC 33 002 : 98 AMD 1 2003

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - ACCESSORIES OF DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 (1,2) KV - TEST METHODS AND REQUIREMENTS

Superseded date

09-01-2010

Published date

01-12-2013

1 Domaine d'application
2 Références normatives
3 Définitions
4 Caractéristiques électriques
  4.1 Tension assignée
  4.2 Intensités admissibles
5 Acceptation de type
  5.1 Généralités
  5.2 Jonctions, dérivations et bouts perdus
  5.3 Jonctions de transition
  5.4 Essais facultatifs
6 Essais de type
  6.1 Généralités
  6.2 Échantillons pour les essais
  6.3 Séquence d'essais
  6.4 Conditions d'essais
  6.5 Fréquence et forme d'onde des tensions d'essai à
      fréquence industrielle
  6.6 Spécifications d'essai
      6.6.1 Détermination de la température du câble
      6.6.2 Stabilité thermique
      6.6.3 Tension de choc à la température ambiante
      6.6.4 Tenue sous tension alternative
      6.6.5 Choc mécanique à basse température
      6.6.6 Choc mécanique à la température ambiante
      6.6.7 Mesure de la résistance d'isolement
      6.6.8 Cycles thermiques
      6.6.9 Pénétration d'eau
      6.6.10 Tenue de l'écran métallique au court-circuit
      6.6.11 Essai d'immersion
      6.6.12 Examen
7 Marquage, étiquetage, conditionnement et informations à donner
  par le fabricant
Annexe A (informative) Détermination de la température de l'âme
                        du câble
Annexe B (normative) Marquage, étiquetage, conditionnement et
                        informations à donner par le fabricant
Annexe NA (normative) Exigences particulières relatives à
                        l'utilisation des accessoires 0,6/1 kV
                        sur les réseaux de distribution publique
                        français

Ce document définit les essais applicables aux accessoires de câbles souterrains de distribution couverts par le document d'harmonisation HD 603 S1. Il s'applique plus particulièrement aux accessoires destinés au câble conforme à la norme NF C 33-210 (HD 603, Partie 5-F). Il définit également les exigences particulières relatives à l'utilisation des accessoires sur les réseaux de distribution publique français.

DevelopmentNote
Indice de classement: C33-002. (01/2004)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

Standards Relationship
HD 623 : S1 AMD 11 2001 Identical

NFC 32 902 : 1998 INSULATED CABLES AND CORDS FOR INSTALLATIONS - POWER CABLE ACCESSORIES INTENDED FOR INDUSTRY, FOR RATED VOLTAGE 0,6/1(1,2) KV - TEST METHODS AND TEST REQUIREMENTS

UTEC 33 013 : 1993 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - PARTICULAR REQUIREMENTS FOR THE USE OF SELF-AMALGAMATING TAPES AND POLYMERISABLE FILLING COMPOUNDS ON FRENCH POWER SYSTEMS
NF EN 61180-1 : 1995 HIGH-VOLTAGE TEST TECHNIQUES FOR LOW-VOLTAGE EQUIPMENT - PART 1: DEFINITIONS, TEST AND PROCEDURE REQUIREMENTS
NFC 33 010 : 93 XP INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - FILLING COMPOUNDS POLYMERISABLE AT AMBIENT TEMPERATURE, CAST OR INJECTED FOR CABLE ACCESSORIES OF RATED VOLTAGES UP TO AND INCLUDING 12/20(24) KV
XP C20 540 : 2002 XP ENVIRONMENTAL TESTING - TEST METHODS - CLIMATIC AGEING TEST OF EQUIPMENT AND SYNTHETIC MATERIALS FOR OUTDOOR USE
NFC 33 210 : 1995 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - CROSS-LINKED POLYETHYLENE INSULATED CABLES COVERED WITH A POLYVINYL CHLORIDE SHEATH - TYPE H1 XDV-A
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
HD 603 S1:1994/A3:2007 DISTRIBUTION CABLES OF RATED VOLTAGE 0,6/1 KV
NFC 33 090-1 : 95 XP COMPRESSION CONNECTORS FOR INSULATED CABLES - PART 1: DEEP STEPPED INDENT CONTROLLED VOLUME COMPRESSION OF ALUMINIUM CONDUCTORS
NFC 33 100 : 65 AMD 1 1967 INSULATED CONDUCTORS FOR POWER SYSTEMS - IMPREGNATED PAPER INSULATED LEAD-SHEATHED CABLES
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
NFC 33 090-4 : 99 XP INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - COMPRESSION CONNECTORS FOR INSULATED CABLES - PART 4: TOOLS AND TOOLING
NFC 63 213 : 2005 LOW-VOLTAGE FUSES - PART 2-1: SUPPLEMENTARY REQUIREMENTS FOR FUSES FOR USE BY AUTHORIZED PERSONS (FUSES MAINLY FOR INDUSTRIAL APPLICATION) - SECTIONS 1 TO 6: EXAMPLES OF TYPES OF STANDARDIZED FUSES
NF EN 60811 1-4 : 96 AMD 2 2002 INSULATING AND SHEETING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 4: TEST AT LOW TEMPERATURE

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.