• There are no items in your cart

NFC 33 061 : 1999

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - JOINTS FOR SINGLE-CORE CABLES WITH POLYMERIC EXTRUDED INSULATION FOR RATED VOLTAGES ABOVE 30 KV (UM EQUAL TO 36 KV) UP TO 500 KV (UM EQUAL TO 525 KV)
Superseded date

08-01-2008

Published date

01-12-2013

AVANT-PROPOS
1 Généralités
   1.1 Domaine d'application
   1.2 Références normatives
   1.3 Définitions
   1.4 Tension assignée
   1.5 Renseignements à fournir lors d'une commande
2 Capacité de transport
3 Constitution des jonctions
4 Caractéristiques des constituants
5 Installation sur le site
6 Essais de type
   6.1 Essais de courte durée de la reconstitution de
       l'enveloppe isolante
   6.2 Essai de cycles thermiques et de court-circuit
   6.3 Essais diélectriques du revêtement extérieur
   6.4 Essais d'étanchéité
   6.5 Essais spécifiques aux jonctions à arrêts d'écrans
   6.6 Essai de longue durée avec cycles thermiques
7 Essais après pose
8 Procédure d'acceptation de type
   8.1 Acceptation de type d'une jonction sans mise à la
       terre ou avec mise à la terre
   8.2 Acceptation de type d'une jonction à arrêts d'écrans
   8.3 Acceptations de type simultanées
   8.4 Réalisation des essais de type
9 Extension de l'acceptation de type en fonction de la
   section de l'âme
10 Extension de l'acceptation de type en fonction de la
   tension
Annexe A (informative) - Conditions de fonctionnement sur le
                         réseau électrique français
Annexe B (informative) - Calcul du courant de court-circuit
                         en tenant compte des effets de l'asymétrie
                         supposée maximale

DevelopmentNote
Indice de Classement: C33-061 (04/2003)
DocumentType
Standard
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

IEC 60228:2004 Conductors of insulated cables
IEC 60502-2:2014 RLV Power cables with extruded insulation and their accessories for rated voltages from 1 kV (<em>U</em><sub>m</sub> = 1,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV) – Part 2: Cables for rated voltages from 6 kV (<em>U</em><sub>m</sub> = 7,2 kV) up to 30 kV (<em>U</em><sub>m</sub> = 36 kV)
NFC 33 253 : 2006 INSULATED CABLES FOR POWER SYSTEMS - SINGLE-CORE CABLES WITH POLYMERIC INSULATION FOR RATED VOLTAGES ABOVE 150 KV (UM = 170 KV) UP TO 500 KV (UM = 525 KV)
NF EN 60071-1 : 2006 AMD 1 2010 INSULATION CO-ORDINATION - PART 1: DEFINITIONS, PRINCIPLES AND RULES
NFC 33 012 : 2016 INSULATED CABLES AND THEIR ACCESSORIES FOR POWER SYSTEMS - SELF-AMALGAMATING INSULATING AND SEMI-CONDUCTING TAPES INTENDED FOR CABLE ACCESSORIES OF RATED VOLTAGES ABOVE 30 KV (UM = 36 KV) AND UP TO 150 KV (UM = 170 KV)
NFC 33 220 : 88 AMD 1 88 INSULATED OR PROTECTED CABLES FOR POWER SYSTEMS - EXTRUDED SOLID DIELECTRIC INSULATED CABLES FOR RATED VOLTAGES FROM 1.8/3(3.6) KV UP TO 18/30(36) KV
NFC 63 061 : 1973 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - CONNECTION JOINTS FOR CONDUCTORS ONE AT LEAST OF THEM BEING AN INSULATED ALUMINIUM OR ALUMINIUM ALLOY CONDUCTOR - ELECTRICAL TEST REQUIREMENTS
IEC 60230:1966 Impulse tests on cables and their accessories
HD 383 : S2 AMD 2 CONDUCTORS OF INSULATED CABLES - GUIDE TO THE DIMENSIONAL LIMITS OF CIRCULAR CONDUCTORS
NFC 32 013 : 1981 INSULATED CABLES AND FLEXIBLE CORDS - CONDUCTORS OF INSULATED CABLES
IEC 60050-461:2008 International Electrotechnical Vocabulary (IEV) - Part 461: Electric cables
NF EN 60811 1-1 : 96 AMD 1 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 1: MEASUREMENT OF THICKNESS AND OVERALL DIMENSIONS - TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
IEC 60060-1:2010 High-voltage test techniques - Part 1: General definitions and test requirements
NF EN 60811 1-2 : 96 AMD 2 2001 INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - COMMON TEST METHODS - PART 1: GENERAL APPLICATION - SECTION 2: THERMAL AGEING METHODS

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.