• There are no items in your cart

NFC 93 533 : 94 AMD 1 96 XP

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

ELECTRONIC COMPONENTS - CABLES WITH PVC INSULATION AND PVC SHEATH FOR WIRING AND INDOOR TRANSMISSION EQUIPMENT - GENERIC SPECIFICATION
Superseded date

01-01-2009

Published date

01-12-2013

AVANT-PROPOS
SECTION UN - GENERALITES
1 Introduction
2 Normes de référence
3 Assurance de la qualité
SECTION DEUX - CONSTRUCTION DU CABLE
4 Conducteur
5 Enveloppe isolante
6 Elément de câblage
7 Mode de câblage
8 Paires de réserve
9 Code des couleurs
10 Revêtement et écran de l'âme
11 Gaine
12 Filin de déchirement
13 Câble en état de livraison
14 Livraison
SECTION TROIS - PRESCRIPTIONS MECANIQUES
15 Conducteur
16 Enveloppe isolante
17 Gaines
SECTION QUATRE - PRESCRIPTIONS THERMIQUES ET
D'ENVIRONNEMENT
18 Enveloppe isolante
19 Gaines
20 Comportement au feu
SECTION CINQ - PRESCRIPTIONS ELECTRIQUES
21 Résistance électrique du conducteur
22 Rigidité diélectrique
23 Résistance d'isolement
Annexe A: Code des couleurs pour les fils de câblage
Annexe B: Code des couleurs des jarretières
Annexe C: Code des couleurs des enveloppes isolantes des
          câbles assemblés ne dépassant pas 60 éléments
          de câblage
Annexe D: Code des couleurs d'identification des faisceaux
          de base et des faisceaux composés

DevelopmentNote
Indice de Classement: C93-533XP. XP NFC 93 533 May 1994. XP NFC 93 533 Amendment 1 March 1996. (02/2002)
DocumentType
Miscellaneous Product
PublisherName
Association Francaise de Normalisation
Status
Superseded
SupersededBy

UTEC 00 131 : 1985 LIST OF THE WIRES AND CABLES TO WHICH THE NF-USE AND THE USE QUALITY MARK HAVE BEEN GRANTED.
IEC 60028:1925 International standard of resistance for copper
NFC 32 033 : 1993 COMMON TEST METHODS FOR INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - METHODS SPECIFIC TO FILLING COMPOUNDS - DROP POINT - SEPARATION OF OIL - LOWER TEMPERATURE - BRITTLENESS TOTAL ACID NUMBER - ABSENCE OF CORROSIVE COMPONENTS - PERMITTIVITY AT 23 DEG C - DC RESISTIVITY AT 23 DEG C AND 100 DEG C
IEC 60189-1:2007 Low-frequency cables and wires with PVC insulation and PVC sheath - Part 1: General test and measuring methods
NFC 32 050 : 1990 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - METAL SHEATHED CABLES - RULES
IEC 60304:1982 Standard colours for insulation for low-frequency cables and wires
NFC 32 061 : 1996 PVC INSULATION AND SHEATH FOR COMMUNICATION CABLES
UTEC 00 130 : 1978 RULES FOR THE GRANTING AND THE MANAGEMENT OF THE NATIONAL MARK OF CONFORMITY WITH THE NF-USE STANDARDS FOR WIRES AND CABLES.
UTEC 32 022 : 92 AMD 1 94 SPARK TEST OF CONDUCTORS OR CABLES WITH AN INSULATION BASED ON RUBBER OR ANOTHER ELASTOMER OR ON POLYVINYL CHLORIDE - GUIDE DETAILING THE TEST APPLICATION PROCEDURES
NFX 08 002 : 1983 FD LIMITED COLLECTION OF COLOURS - DESIGNATION AND CATALOGUE OF CCR COLOURS - SECONDARY STANDARDS
NFC 31 111 : 1992 WIRES FOR ELECTRICAL MACHINERY AND APPARATUS - ROUND BARE ANNEALED COPPER WIRE - CHARACTERISTICS
NFC 32 070 : 2001 AMD 1 2005 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - CLASSIFICATION TESTS ON CABLES AND CORDS WITH RESPECT TO THEIR BEHAVIOUR TO FIRE
IEC TR 60344:2007 Calculation of d.c. resistance of plain and coated copper conductors of low-frequency cables and wires - Application guide
NFC 32 024 : 88 ADD 1 93 COMMON TEST METHODS FOR INSULATING & SHEATHING MATERIALS OF ELECTRIC CABLES: METHODS FOR GENERAL APPLICATION: MEASUREMENT OF THICKNESS OVERALL DIMENSIONS TESTS FOR DETERMINING THE MECHANICAL PROPERTIES
NFC 32 021 : 1985 INSULATED CABLES AND FLEXIBLE CORDS FOR INSTALLATIONS - TEST METHODS FOR CABLES AND CORDS USED UNDER SPECIAL CONDITIONS
IEC 60811-5-1:1990+AMD1:2003 CSV Insulating and sheathing materials of electric and optical cables - Common test methods - Part 5-1: Methods specific to filling compounds - Drop-point - Separation of oil - Lower temperature brittleness - Total acid number - Absence of corrosive components - Permittivity at 23 °C - DC resistivity at 23 °C and 100 °C
NFC 32 031 : 88 AMD 1 93 COMMON TEST METHODS FOR INSULATING AND SHEATHING MATERIALS OF ELECTRIC CABLES - METHODS SPECIFIC TO POLYETHYLENE & POLYPROPYLENE COMPOUND - RESISTANCE TO ENVIRONMENTAL STRESS CRACKING WRAPPING TEST AFTER THERMAL AGEING IN AIR - MEASUREMENT OF THE MELT FLOW INDEX - CARBON BLACK AND/OR MINERAL CONTENT MEASUREMENT IN PE

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.