TESTING PROCEDURES FOR LOCAL, AUXILIARY, REMOTE STATION, AND PROPRIETARY PROTECTIVE SIGNALING SYSTEMS
04-14-2021
01-12-2013
Chapter 1 General
1.1 Scope
1.2 Definitions
1.3 Fire Alarm System Certification and Description
Document
Chapter 2 Acceptance and Reacceptance Testing Procedures
2.1 General
2.2 Installation Testing
2.3 System Testing
2.4 Reacceptance Testing
Chapter 3 Periodic Equipment and Circuit Testing
Procedures
3.1 Periodic Testing
Chapter 4 Recommended Schedules and Methods for Testing
Procedures
4.1 General
Chapter 5 Procedure for Testing Systems Equipped with
Alarm Verification
Chapter 6 Multiplex System Testing Procedures
Chapter 7 Typical Circuit Wiring Diagrams
7.1
7.2 Diagram of Nonpowered Alarm or Supervisory
Initiating Devices (e.g. Manual Station or Valve
Supervisory Switch) Connected to Style A, B, or C
Initiating Device Circuits
7.3 Diagram of Nonpowered Alarm or Supervisory
Initiating Devices Connected to Style D or E
Initiating Device Circuits
7.4 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
for Style A, B, or C Initiating Device Circuits
7.5 Diagram of Circuit-Powered (2-Wire) Smoke Detectors
for Style D or E Initiating Device Circuits
7.6 Diagram of Combination Alarm Initiating Device and
Indicating Appliance Circuits
7.7 Diagram of Combination Alarm Initiating Device and
Indicating Circuits Arranged for Operation with a
Single Open or Ground Fault
7.8 Diagram of Style A, B, or C Circuits with 4-Wire
Smoke Detectors and an End-of-Line Power Supervision
Relay
7.9 Diagram of Style A, B, or C Initiating Device
Circuits with 4-Wire Smoke Detectors that Include
Integral Individual Supervision Relays
7.10 Diagrams of Alarm Indicating Appliances
7.11 Diagram of System with a Supervised Audible
Indicating Appliance Circuit and an Unsupervised
Visible Indicating Appliance Circuit
7.12 Diagram of System with Supervised Audible and
Visible Indicating Appliance Circuits
7.13 Diagram of Series Indicating Appliance Circuit,
which No Longer Meets the Requirements of NFPA 72A,
NFPA 72D, and NFPA 72F
7.14 Diagram of Supervised Series Supervisory Initiating
Circuit with Sprinkler Supervisory Valve Switches
Connected, which No Longer Meets the Requirements
of NFPA 72A, NFPA 72D, and NFPA 72F
7.15 Diagram of Initiating Device Circuit with Parallel
Waterflow Alarm Switches and a Series Supervisory
Valve Switch, which No Longer Meets the Requirements
of NFPA 72A, NFPA 72D, or NFPA 72F
7.16 Diagram of an Auxiliary Circuit Connected to a
Municipal Fire Alarm Master Box
7.17 Diagram of Door Hold and Release Unit with
Unsupervised Wiring
7.18 Diagram of Remote Relays Connected to an
Unsupervised Indicating Appliance Circuit