DISTRICT HEATING PIPES - PREINSULATED BONDED PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - PIPE ASSEMBLY OF STEEL SERVICE PIPE, POLYURETHANE THERMAL INSULATION AND OUTER CASING OF POLYETHYLENE
Withdrawn date

03-15-2020

Published date

01-12-2013

Für erdverlegte Fernwärmenetze bis DN 600 sind die Anforderungen und Prüfmethoden für gerade, werksmässig gedämmte Mantelrohre festgelegt, die aus einem Stahlrohr als Mediumrohr, einer Polyurethan-Hartschaumdämmung und einem Mantelrohr aus Polyethylen hoher Dichte bestehen. Die Stahl- und Dämmwerkstoffe sowie die Prüfungen und Prüfmethoden sind ebenso angeführt wie die Verarbeitungsvorschriften. Die Lebensdauer in Abhängigkeit von der Betriebstemperatur ist erwähnt. Die erforderliche Kennzeichnung durch den Hersteller wird angeben. In den informativen Anhängen A, B und C sind der Zusammenhang von Betriebstemperatur und Lebensdauer, die Abschätzung der Lebensdauer selbst sowie die Qualitätssicherung beschrieben. Diese Norm ist Basis der Normenreihe für Verbundmantelrohrsysteme und wird durch Festlegungen für weitere Bauteile ergänzt. In diese ÖNORM wurde die Europäische Änderung A1:2005 eingearbeitet. wobei Änderungen zum Vorwort und zur Einleitung, zu 4.3.2.1, 4.3.2.2, 4.5.2 und zu Anhang D durchgeführt wurden. Die Unterabschnitte 4.3.2.3 alt und 5.4.1 alt wurden gänzlich gestrichen. Weiters wurde in diese ÖNORM die Europäische Änderung A2:2006 eingearbeitet, wobei Änderungen zu 4.2.1 und zum Anhang H durchgeführt wurden.

Committee
TC 117
DocumentType
Standard
PublisherName
Osterreichisches Normungsinstitut/Austrian Standards
Status
Withdrawn
SupersededBy

ONORM EN 15698-2 : 2015 DISTRICT HEATING PIPES - PREINSULATED BONDED TWIN PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - PART 2: FITTING AND VALVE ASSEMBLY OF STEEL SERVICE PIPES, POLYURETHANE THERMAL INSULATION AND OUTER CASING OF POLYETHYLENE
ONORM EN 15632-1 : 2015 DISTRICT HEATING PIPES - PRE-INSULATED FLEXIBLE PIPE SYSTEMS - PART 1: CLASSIFICATION, GENERAL REQUIREMENTS AND TEST METHODS
ONORM EN 14419 : 2009 DISTRICT HEATING PIPES - PREINSULATED BONDED PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - SURVEILLANCE SYSTEMS
ONORM EN 15698-1 : 2009 DISTRICT HEATING PIPES - PREINSULATED BONDED TWIN PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - PART 1: TWIN PIPE ASSEMBLY OF STEEL SERVICE PIPE, POLYURETHANE THERMAL INSULATION AND OUTER CASING OF POLYETHYLENE
ONORM EN ISO 12736 : 2015 PETROLEUM AND NATURAL GAS INDUSTRIES - WET THERMAL INSULATION COATINGS FOR PIPELINES, FLOW LINES, EQUIPMENT AND SUBSEA STRUCTURES (ISO 12736:2014)

ISO 8501-1:2007 Preparation of steel substrates before application of paints and related products — Visual assessment of surface cleanliness — Part 1: Rust grades and preparation grades of uncoated steel substrates and of steel substrates after overall removal of previous coatings
ISO 13953:2001 Polyethylene (PE) pipes and fittings — Determination of the tensile strength and failure mode of test pieces from a butt-fused joint
ISO 1133-1:2011 Plastics Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Part 1: Standard method
ONORM EN 10217-2 : 2007 WELDED STEEL TUBES FOR PRESSURE PURPOSES - TECHNICAL DELIVERY CONDITIONS - PART 2: ELECTRIC WELDED NON-ALLOY AND ALLOY STEEL TUBES WITH SPECIFIED ELEVATED TEMPERATURE PROPERTIES
ISO 16770:2004 Plastics Determination of environmental stress cracking (ESC) of polyethylene Full-notch creep test (FNCT)
ISO 3127:1994 Thermoplastics pipes — Determination of resistance to external blows — Round-the-clock method
ONORM EN 10217-5 : 2007 WELDED STEEL TUBES FOR PRESSURE PURPOSES - TECHNICAL DELIVERY CONDITIONS - PART 5: SUBMERGED ARC WELDED NON-ALLOY AND ALLOY STEEL TUBES WITH SPECIFIED ELEVATED TEMPERATURE PROPERTIES
ISO 6964:1986 Polyolefin pipes and fittings Determination of carbon black content by calcination and pyrolysis Test method and basic specification
ONORM EN ISO 12162 : 2010 THERMOPLASTICS MATERIALS FOR PIPES AND FITTINGS FOR PRESSURE APPLICATIONS - CLASSIFICATION, DESIGNATION AND DESIGN COEFFICIENT
ISO 9080:2012 Plastics piping and ducting systems — Determination of the long-term hydrostatic strength of thermoplastics materials in pipe form by extrapolation
ISO 8497:1994 Thermal insulation — Determination of steady-state thermal transmission properties of thermal insulation for circular pipes
ISO 12162:2009 Thermoplastics materials for pipes and fittings for pressure applications Classification, designation and design coefficient
ONORM EN 10216-2 : 2014 SEAMLESS STEEL TUBES FOR PRESSURE PURPOSES - TECHNICAL DELIVERY CONDITIONS - PART 2: NON-ALLOY AND ALLOY STEEL TUBES WITH SPECIFIED ELEVATED TEMPERATURE PROPERTIES
ISO 9692-1:2013 Welding and allied processes — Types of joint preparation — Part 1: Manual metal arc welding, gas-shielded metal arc welding, gas welding, TIG welding and beam welding of steels
ISO 3126:2005 Plastics piping systems Plastics components Determination of dimensions
ONORM EN 10217-1 : 2007 WELDED STEEL TUBES FOR PRESSURE PURPOSES - TECHNICAL DELIVERY CONDITIONS - PART 1: NON-ALLOY STEEL TUBES WITH SPECIFIED ROOM TEMPERATURE PROPERTIES
ONORM EN ISO 2505 : 2005 THERMOPLASTICS PIPES - LONGITUDINAL REVERSION - TEST METHOD AND PARAMETERS
ONORM EN 14419 : 2009 DISTRICT HEATING PIPES - PREINSULATED BONDED PIPE SYSTEMS FOR DIRECTLY BURIED HOT WATER NETWORKS - SURVEILLANCE SYSTEMS
ONORM EN ISO 1133-1 : 2012 PLASTICS - DETERMINATION OF THE MELT MASS-FLOW RATE (MFR) AND MELT VOLUME-FLOW RATE (MVR) OF THERMOPLASTICS - PART 1: STANDARD METHOD (ISO 1133-1:2011)
ISO 1133-2:2011 Plastics Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics Part 2: Method for materials sensitive to time-temperature history and/or moisture
ISO 844:2014 Rigid cellular plastics Determination of compression properties
ISO 2505:2005 Thermoplastics pipes — Longitudinal reversion — Test method and parameters

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.