AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 406: VIBRATION

Available format(s)

Hardcopy , PDF

Withdrawn date

12-21-2023

Language(s)

English

Foreword
1 Scope
2 Normative references
3 Preparation of specimens
4 Apparatus
5 Test methods
6 Requirements

Describes the method and means required for testing the vibration resistance of protection sleeve for electrical cable and cable bundles for aerospace application.

DevelopmentNote
To be read in conjunction with PREN 6059-100. (08/2003)
DocumentType
Draft
Pages
10
ProductNote
Superseded by EN 6059-406:2014
PublisherName
Aerospace & Defence Industries Association of Europe
Status
Withdrawn
SupersededBy

Standards Relationship
DIN EN 6059-406:2014-07 Identical
NF EN 6059-406 : 2015 Identical
12/30259525 DC : 0 Identical

PREN 6049-009 : 200P3 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 009: SELF-WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
I.S. EN 6049-007:2012 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 007: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 D EGREES C TO 260 DEGREES C - PRODUCT STANDARD
PREN 6049-006 : 200P4 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD
BS EN 6049-007:2012 Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping mechanical and electrical protective sleeve, flexible post installation operating temperature from -55°C to 260°C. Product standard
12/30275061 DC : 0 BS EN 6049-009 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTIVE SLEEVE IN ARAMID FIBRES - PART 009: SELF WRAPPING FIRE PROTECTION SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
PREN 4674-001 : DRAFT 2015 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION
PREN 4674-004 : 200P1 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 004: OPEN SLEEVE - OUTSIDE PRESSURIZED AREA - EMI PROTECTION 10 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD
EN 6049-001:2015 Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 001: Technical specification
15/30334224 DC : 0 BS EN 6049-008 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION, PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 008: SELF-WRAPPING SHIELDED (EMI) PROTECTIVE SLEEVE WITH NICKEL COPPER BRAID, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREE C TO 200 DEGREE C - PRODUCT STANDARD
UNI EN 6049-007 : 2012 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 007: SELF-WRAPPING MECHANICAL AND ELECTRICAL PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM - 55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
UNI EN 6049-006 : 2012 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD
BS EN 6049-001:2015 Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Technical specification
08/30185299 DC : DRAFT JULY 2008 BS EN 6049-006 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD
15/30322426 DC : 0 BS EN 6049-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION
14/30314814 DC : 0 BS EN 4674-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 001: TECHNICAL SPECIFICATION
15/30322162 DC : 0 BS EN 4674-003 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD
12/30271082 DC : 0 BS EN 6049-001 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION
12/30263294 DC : 0 BS EN 6059-100 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 100: GENERAL
EN 6049-006:2012 Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 006: Self-wrapping protective sleeve, flexible post installation - Product standard
EN 6049-007:2012 Aerospace series - Electrical cables, installation - Protection sleeve in meta-aramid fibres - Part 007: Self-wrapping mechanical and electrical protective sleeve, flexible post installation operating temperature from - 55 °C to 260 °C - Product standard
PREN 4674-003 : 200P2 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - SELF-WRAPPING SHIELDING (EMI) PROTECTIVE SLEEVE - PART 003: OPEN SLEEVE - INSIDE PRESSURIZED AREA - EMI PROTECTION 5 KA - TEMPERATURE RANGE -65 DEGREES C TO 200 DEGREES C - PRODUCT STANDARD
PREN 6049-007 : 200P1 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 007: SELF-WRAPPING MECHANICAL AND ELECTRICAL PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION OPERATING TEMPERATURE FROM -55 DEGREES C TO 260 DEGREES C - PRODUCT STANDARD
I.S. EN 6049-001:2015 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 001: TECHNICAL SPECIFICATION
I.S. EN 6049-006:2012 AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVE IN META-ARAMID FIBRES - PART 006: SELF-WRAPPING PROTECTIVE SLEEVE, FLEXIBLE POST INSTALLATION - PRODUCT STANDARD
08/30192674 DC : 0 BS EN 6059-100 - AEROSPACE SERIES - ELECTRICAL CABLES, INSTALLATION - PROTECTION SLEEVES - TEST METHODS - PART 100: GENERAL
BS EN 6049-006:2012 Aerospace series. Electrical cables, installation. Protection sleeve in meta-aramid fibres Self-wrapping protective sleeve, flexible post installation. Product standard

EN 6059-100:2015 Aerospace series - Electrical cables, installation - Protection sleeves - Test methods - Part 100: General
EN 3838:2010 Aerospace series - Requirements and tests on user-applied markings on aircraft electrical cables
SAE AS 23190 : 2015 WIRING, POSITIONING, AND SUPPORT ACCESSORIES
MS21919 Revision E:1981 CLAMP, LOOP TYPE, CUSHIONED, SUPPORT
PREN 2266-004 : 200P1 AEROSPACE SERIES - CABLES, ELECTRICAL, FOR GENERAL PURPOSE - OPERATING TEMPERATURES BETWEEN -55 DEGREES C AND 200 DEGREES C - PART 004: CO[2] LASER PRINTABLE - PRODUCT STANDARD
EN 2267-010:2017 Aerospace series - Cables, electrical, for general purpose - Operating temperatures between -55 °C and 260 °C - Part 010: DR family, single UV laser printable - Product standard
ISO 7137:1995 Aircraft — Environmental conditions and test procedures for airborne equipment
MIL-DTL-85052 Revision B:2005 CLAMP, LOOP, CUSHION, GENERAL SPECIFICATION FOR

View more information
US$105.91
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.