• There are no items in your cart

TR 102 273-2 : 1.2.1

Current
Current

The latest, up-to-date edition.

ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 2: ANECHOIC CHAMBER
Available format(s)

Hardcopy , PDF

Language(s)

English

Intellectual Property Rights
Foreword
1 Scope
2 References
3 Definitions, symbols and abbreviations
  3.1 Definitions
  3.2 Symbols
  3.3 Abbreviations
4 Introduction
5 Uncertainty contributions specific to an Anechoic
  Chamber
  5.1 Effects of the metal shielding
      5.1.1 Resonances
      5.1.2 Imaging of antennas (or an EUT)
  5.2 Effects of the radio absorbing materials
      5.2.1 Introduction
      5.2.2 Pyramidal absorbers
      5.2.3 Wedge absorbers
      5.2.4 Ferrite tiles
      5.2.5 Ferrite grids
      5.2.6 Urethane/ferrite hybrids
      5.2.7 Floor absorbers
      5.2.8 Performance comparison
      5.2.9 Reflection in an Anechoic Chamber
      5.2.10 Mutual coupling due to imaging in the
             absorbing material
  5.3 Other effects
      5.3.1 Extraneous reflections
      5.3.2 Mutual coupling between antennas (or antenna
            and EUT)
      5.3.3 Turntable and antenna mounting fixtures
      5.3.4 Antenna cabling
      5.3.5 Positioning of the EUT and antennas
      5.3.6 Equipment cabling
6 Verification procedure for an Anechoic Chamber
  6.1 Introduction
  6.2 Normalized site attenuation
      6.2.1 NSA for the ideal Anechoic Chamber
      6.2.2 Mutual coupling
  6.3 Overview of the verification procedure
      6.3.1 Apparatus required
      6.3.2 Site preparation
      6.3.3 Measurement configuration
      6.3.4 What to record
  6.4 Verification procedure
      6.4.1 Procedure 1: 30 MHz to 1 000 MHz
      6.4.2 Alternative Procedure 1: 30 MHz to 1 000 MHz
      6.4.3 Procedure 2: 1 GHz to 12,75 GHz
  6.5 Processing the results of the verification procedure
      6.5.1 Introduction
      6.5.2 Procedure 1: 30 MHz to 1 000 MHz
      6.5.3 Procedure 2 (1 GHz to 12,75 GHz)
      6.5.4 Report format
  6.6 Calculation of measurement uncertainty (Procedure 1)
      6.6.1 Uncertainty contribution, direct attenuation
            measurement
      6.6.2 Uncertainty contribution, NSA measurement
      6.6.3 Expanded uncertainty of the verification procedure
  6.7 Calculation of measurement uncertainty (Procedure 2)
      6.7.1 Uncertainty contribution, direct attenuation
            measurement
      6.7.2 Uncertainty contribution, NSA measurement
      6.7.3 Expanded uncertainty of the verification procedure
  6.8 Summary
7 Test methods
  7.1 Introduction
      7.1.1 Site preparation
      7.1.2 Preparation of the EUT
      7.1.3 Standard antennas
      7.1.4 Mutual coupling and mismatch loss correction
            factors
      7.1.5 Power supplies to the EUT
      7.1.6 Restrictions
  7.2 Transmitter tests
      7.2.1 Frequency error (30 MHz to 1 000 MHz)
            7.2.1.1 Apparatus required
            7.2.1.2 Method of measurement
            7.2.1.3 Procedure for completion of the results
                    sheets
            7.2.1.4 Log book entries
            7.2.1.5 Statement of results
      7.2.2 Expanded uncertainty for frequency error test
      7.2.3 Effective radiated power (30 MHz to 1 000 MHz)
            7.2.3.1 Apparatus required
            7.2.3.2 Method of measurement
            7.2.3.3 Procedure for the completion of the
                    results sheets
            7.2.3.4 Log book entries
            7.2.3.5 Statement of results
      7.2.4 Measurement uncertainty for effective radiated
            power
            7.2.4.1 Uncertainty contributions: Stage 1: EUT
                    measurement
            7.2.4.2 Uncertainty contributions: Stage 2:
                    Substitution measurement
            7.2.4.3 Expanded uncertainty of the ERP
                    measurement
      7.2.5 Spurious emissions (30 MHz to 4 GHz or 12,75 GHz)
            7.2.5.1 Apparatus required
            7.2.5.2 Method of measurement
            7.2.5.3 Procedure for completion of the results
                    sheets
            7.2.5.4 Log book entries
            7.2.5.5 Statement of results
      7.2.6 Measurement uncertainty for Spurious emissions
            7.2.6.1 Uncertainty contributions: Stage 1: EUT
                    measurement
            7.2.6.2 Uncertainty contributions: Stage 2:
                    Substitution measurement
            7.2.6.3 Expanded uncertainty of the spurious
                    emission
      7.2.7 Adjacent channel power
  7.3 Receiver tests
      7.3.1 Sensitivity tests (30 MHz to 1 000 MHz)
            7.3.1.1 Apparatus required
            7.3.1.2 Method of measurement
            7.3.1.3 Procedure for completion of the results
                    sheets
            7.3.1.4 Log book entries
            7.3.1.5 Statement of results
      7.3.2 Measurement uncertainty for Receiver sensitivity
            7.3.2.1 Uncertainty contributions: Stage 1:
                    Determination of Transform Factor
            7.3.2.2 Uncertainty contributions: Stage 2:
                    EUT measurement
            7.3.2.3 Expanded uncertainty of the receiver
                    sensitivity measurement
      7.3.3 Co-channel rejection
      7.3.4 Adjacent channel selectivity
      7.3.5 Intermodulation immunity
      7.3.6 Blocking immunity or desensitization
      7.3.7 Spurious response immunity to radiated fields
            (30 MHz to 4 GHz)
            7.3.7.1 Apparatus required
            7.3.7.2 Method of measurement
            7.3.7.3 Procedure for completion of the results
                    sheets
            7.3.7.4 Log book entries
            7.3.7.5 Statement of results
      7.3.8 Measurement uncertainty for Spurious response
            immunity
            7.3.8.1 Uncertainty contributions: Stage 1:
                    Transform factor
            7.3.8.2 Uncertainty contributions: Stage 2:
                    EUT measurement
            7.3.8.3 Expanded uncertainty of the spurious
                    response immunity measurement
Annex A: Bibliography
History

Gives background to the subject of measurement uncertainty and proposes extensions and improvements relevant to radiated measurements.

Committee
ERM RP02
DocumentType
Standard
Pages
107
PublisherName
European Telecommunications Standards Institute
Status
Current

TS 103 051 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); EXPANDED MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS
CSA ISO/IEC TR 18047-6 : 2013 INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ
PD ISO/IEC TR 18047-6:2011 Information technology. Radio frequency identification device conformance test methods Test methods for air interface communications at 860 MHz to 960 MHz
EN 302 291-1 : 1.1.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); SHORT RANGE DEVICES (SRD); CLOSE RANGE INDUCTIVE DATA COMMUNICATION EQUIPMENT OPERATING AT 13,56 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND TEST METHODS
EN 301 598 : 2.1.1 WHITE SPACE DEVICES (WSD); WIRELESS ACCESS SYSTEMS OPERATING IN THE 470 MHZ TO 790 MHZ TV BROADCAST BAND; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU
BS ISO/IEC 18047-6:2017 Information technology. Radio frequency identification device conformance test methods Test methods for air interface communications at 860 MHz to 960 MHz
ISO/IEC 18047-6:2017 Information technology — Radio frequency identification device conformance test methods — Part 6: Test methods for air interface communications at 860 MHz to 960 MHz
TR 102 215 : 1.3.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); RECOMMENDED APPROACH, AND POSSIBLE LIMITS FOR MEASUREMENT UNCERTAINTY FOR THE MEASUREMENT OF RADIATED ELECTROMAGNETIC FIELDS ABOVE 1 GHZ
EG 202 290 : 1.1.1 FINAL DRAFT ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); MEASUREMENT UNCERTAINTIES AND TEST METHODOLOGIES FROM 1 GHZ TO 40 GHZ
12/30257202 DC : 0 BS ISO/IEC 18047-6 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ
ISO/IEC TR 18047-6:2011 Information technology Radio frequency identification device conformance test methods Part 6: Test methods for air interface communications at 860 MHz to 960 MHz
EN 300 330 : 2.1.1 SHORT RANGE DEVICES (SRD); RADIO EQUIPMENT IN THE FREQUENCY RANGE 9 KHZ TO 25 MHZ AND INDUCTIVE LOOP SYSTEMS IN THE FREQUENCY RANGE 9 KHZ TO 30 MHZ; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU
EN 300 220-1 : 2.4.1 SHORT RANGE DEVICES (SRD) OPERATING IN THE FREQUENCY RANGE 25 MHZ TO 1000 MHZ; PART 1: TECHNICAL CHARACTERISTICS AND METHODS OF MEASUREMENT
EN 301 893 : 1.8.1 5 GHZ RLAN; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU
16/30315793 DC : 0 BS ISO/IEC 18047-6 - INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ
EN 300 674-2-1 : 1.1.1 TRANSPORT AND TRAFFIC TELEMATICS (TTT); DEDICATED SHORT RANGE COMMUNICATION (DSRC) TRANSMISSION EQUIPMENT (500 KBIT/S/250 KBIT/S) OPERATING IN THE 5795 MHZ TO 5815 MHZ FREQUENCY BAND; PART 2: HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF THE DIRECTIVE 2014/53/EU; SUB-PART 1: ROAD SIDE UNITS (RSU)
ECMA/TR 94 : 1ED 2007 ASSESSMENT OF THE HUMAN EXPOSURE TO ELECTROMAGNETIC FIELDS FOR LOW POWER ELECTRONIC AND ELECTRICAL APPARATUS ACCORDING TO EN 50371:2002
CSA ISO/IEC TR 18047-6 : 2013 : R2017 INFORMATION TECHNOLOGY - RADIO FREQUENCY IDENTIFICATION DEVICE CONFORMANCE TEST METHODS - PART 6: TEST METHODS FOR AIR INTERFACE COMMUNICATIONS AT 860 MHZ TO 960 MHZ
EN 300 328 : 2.1.1 WIDEBAND TRANSMISSION SYSTEMS; DATA TRANSMISSION EQUIPMENT OPERATING IN THE 2,4 GHZ ISM BAND AND USING WIDE BAND MODULATION TECHNIQUES; HARMONISED STANDARD COVERING THE ESSENTIAL REQUIREMENTS OF ARTICLE 3.2 OF DIRECTIVE 2014/53/EU

TR 102 273-1-2 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 2: EXAMPLES AND ANNEXES
TR 100 028-1 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 1
EN 50147-2 : 1996 ANECHOIC CHAMBERS - PART 2: ALTERNATIVE TEST SITE SUITABILITY WITH RESPECT TO SITE ATTENUATION
TR 102 273-1-1 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); IMPROVEMENT ON RADIATED METHODS OF MEASUREMENT (USING TEST SITE) AND EVALUATION OF THE CORRESPONDING MEASUREMENT UNCERTAINTIES; PART 1: UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS; SUB-PART 1: INTRODUCTION
ANSI C63.5 : 2006 ELECTROMAGNETIC COMPATIBILITY - RADIATED EMISSION MEASUREMENTS IN ELECTROMAGNETIC INTERFERENCE (EMI) CONTROL - CALIBRATION AND QUALIFICATION OF ANTENNAS (9 KHZ TO 40 GHZ)
TR 100 027 : 1.2.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); METHODS OF MEASUREMENT FOR PRIVATE MOBILE RADIO EQUIPMENT
TR 100 028-2 : 1.4.1 ELECTROMAGNETIC COMPATIBILITY AND RADIO SPECTRUM MATTERS (ERM); UNCERTAINTIES IN THE MEASUREMENT OF MOBILE RADIO EQUIPMENT CHARACTERISTICS PART 2

View more information
US$47.91
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.