• There are no items in your cart

UNE-HD 603.5X:2007

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Distribution cables of rated voltage 0,6/1 kV. Part 5: XLPE insulated cables unarmoured. Section X: Polyolefin sheathed cables without concentric conductor (Type 5X-1)
Available format(s)

Hardcopy , PDF

Withdrawn date

12-31-2017

Language(s)

Spanish, Castilian, English

Published date

11-14-2007

Committee
CTN 211/SC 20A
DevelopmentNote
Supersedes UNE 211603-5N1. (01/2008) Supersedes UNE 211603. (01/2018)
DocumentType
Standard
Pages
16
ProductNote
New Child AMD 1 2017 is now added
PublisherName
Asociacion Espanola de Normalizacion
Status
Withdrawn
Supersedes

Standards Relationship
HD 603 S1:1994/A3:2007 Identical

UNE 211435:2011 Guidance on the selection of distribution cables for rated voltages up to and including 0,6/1 kV.
UNE 211029:2013 Cable accessories. Connection assemblies to be used in underground distribution networks with cables of rated voltage 0,6/1 kV
UNE 211022:2016 Cable accessories. Isolated connectors for use on underground distribution cables for rated voltage 0,6/1 kV.
UNE 211023:2010 Cable accessories. Isolated joints for use on underground distribution cables for rated voltage 0,6/1 kV.

EN 60811-409:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 409: Miscellaneous tests - Loss of mass test for thermoplastic insulations and sheaths
EN 60811-505:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 505: Mechanical tests - Elongation at low temperature for insulations and sheaths
EN 60811-504:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 504: Mechanical tests - Bending tests at low temperature for insulation and sheaths
HD 605 S2:2008/corrigendum:2010 ELECTRIC CABLES - ADDITIONAL TEST METHODS
EN 60811-501:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 501: Mechanical tests - Tests for determining the mechanical properties of insulating and sheathing compounds
EN 60228:2005 COR 2005 CONDUCTORS OF INSULATED CABLES
UNE-HD 603-1:2007 Distribution cables of rated voltage 0,6/1 kV. Part 1: General requirements.
UNE 211435:2011 Guidance on the selection of distribution cables for rated voltages up to and including 0,6/1 kV.
EN 50575:2014/A1:2016 POWER, CONTROL AND COMMUNICATION CABLES - CABLES FOR GENERAL APPLICATIONS IN CONSTRUCTION WORKS SUBJECT TO REACTION TO FIRE REQUIREMENTS
EN 60811-502 : 2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 502: Mechanical tests - Shrinkage test for insulations
EN 60811-506:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 506: Mechanical tests - Impact test at low temperature for insulations and sheaths
EN 61034-2:2005/A1:2013 MEASUREMENT OF SMOKE DENSITY OF CABLES BURNING UNDER DEFINED CONDITIONS - PART 2: TEST PROCEDURE AND REQUIREMENTS (IEC 61034-2:2005/A1:2013)
IEC 60183:2015 Guidance for the selection of high-voltage A.C. cable systems
IEC 62230:2006+AMD1:2013 CSV Electric cables - Spark-test method
EN 60811-507 : 2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 507: Mechanical tests - Hot set test for cross-linked materials
UNE 211605:2013 Climatic ageing test of outer covering cables.
EN 60811-402:2012 Electric and optical fibre cables - Test methods for non-metallic materials - Part 402: Miscellaneous tests - Water absorption tests

View more information
US$65.77
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.