• There are no items in your cart

UNI EN 81-3 : 2008

Current
Current

The latest, up-to-date edition.

SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 3: ELECTRIC AND HYDRAULIC SERVICE LIFTS
Published date

11-06-2008

Foreword
Introduction
   0.1 General
1 Scope
2 Normative references
3 Terms and definitions
4 Units and symbols
   4.1 Units
   4.2 Symbols
5 Service lift well
   5.1 General provisions
   5.2 Well enclosure
   5.3 Walls, floor and ceiling of the well
   5.4 Protection of any spaces located below the car,
         the counterweight or the balancing weight
   5.5 Protection in the well
   5.6 Headroom and pit
   5.7 Exclusive use of the service lift well
6 Machine rooms
   6.1 General provisions
   6.2 Access
   6.3 Construction and equipment of machine rooms
7 Landing doors
   7.1 General provisions
   7.2 Strength of doors and their frames
   7.3 Height and width of entrances
   7.4 Sills, guides, door suspension
   7.5 Protection in relation to door operation
   7.6 Local lighting and 'car here' signal lights
   7.7 Locking and closed landing door check
8 Car, counterweight and balancing weight
   8.1 Height of car
   8.2 Available car area and rated load
   8.3 Walls, floor and roof of the car
   8.4 Apron and automatic bridging sills
   8.5 Car entrance
   8.6 Car doors
   8.7 Protection during operation of doors
   8.8 Counterweight and balancing weight
9 Suspension, precautions against free fall, descent
   with excessive speed and creeping of the car
   9.1 Suspension
   9.2 Sheave, pulley, drum and rope diameter ratios,
         rope/chain terminations
   9.3 Rope traction
   9.4 Winding up of ropes for positive drive service lifts
   9.5 Distribution of load between the ropes or the chains
   9.6 Protection for traction sheaves, pulleys and sprockets
   9.7 Precautions against free fall, descent with excessive
         speed, creeping of the car and against free fall of
         the counterweight or balancing weight
   9.8 Safety gear
   9.9 Tripping means for safety gear
10 Guide rails, buffers and final limit switches
   10.1 General provisions concerning guide rails
   10.2 Guiding of the car, counterweight or balancing weight
   10.3 Buffers and fixed stops for car and counterweight
   10.4 Car and counterweight buffers
   10.5 Final limit switches
11 Clearances between the car and wall facing the car entrance
   11.1 General provision
   11.2 Clearance between car and wall facing the car entrance
12 Lift machine
   12.1 General provisions
   12.2 Service lift machines for electric service lifts
   12.3 Machine, jack and other hydraulic equipment for
         hydraulic service lifts
13 Electric installations and appliances
   13.1 General provisions
   13.2 Contactors, relay-contactors, components of safety
         circuits
   13.3 Protection of motors
   13.4 Main switches
   13.5 Electric wiring
   13.6 Lighting and socket outlets
14 Protection against electric faults; controls; priorities
   14.1 Failure analysis and electric safety devices
   14.2 Controls
15 Notices, markings and operating instructions
   15.1 General provisions
   15.2 Rated load and vendor's name
   15.3 Car roof
   15.4 Machine rooms
   15.5 Well
   15.6 Overspeed governor
   15.7 Pit
   15.8 Electrical identification
   15.9 Unlocking key for landing doors
   15.10 Locking devices
   15.11 Groups of lifts
   15.12 Tank
16 Examinations - Tests - Register - Maintenance
   16.1 Examinations and tests
   16.2 Register
   16.3 Vendor information
Annex A (normative) - List of the electric safety devices
Annex B (normative) - Unlocking triangle
Annex C (informative) - Technical dossier
      C.1 Introduction
      C.2 General
      C.3 Technical details and plans
      C.4 Electric schematic diagrams and hydraulic
          circuit diagrams
Annex D (normative) - Examinations and tests before
        putting into service
      D.1 Examinations
      D.2 Tests and verifications
Annex E (normative) - Periodical examinations and tests,
        examinations and tests after an important
        modification or after an accident
      E.1 Periodical examinations and tests (normative)
      E.2 Examinations and tests after important modifications
          or after accidents (informative)
Annex F (informative) - Construction of walls of service lift
        wells and landing doors facing a car entrance
Annex G (normative) - Electronic components - Failure exclusion
Annex H (normative) - Calculations of rams, cylinders, rigid
        pipes and fittings
      H.1 Calculation against over pressure
      H.2 Calculations of the jacks against buckling
Annex J (informative) - Information to the owner/user of
        a service lift
      J.1 Means of access to machine room entrance of the
          service lift
      J.2 Maintenance work carried out from a step of a ladder
Annex ZA (informative) - Relationship between this European
         Standard and the Essential Requirements of EC
         Directive 98/37/EC
Annex ZB (informative) - Relationship between this European
         Standard and the Essential Requirements of EC
         Directive 2006/42/EC
Bibliography

Describes the safety rules for the construction and installation of permanently installed new electric service lifts with traction or positive drive, or hydraulic service lifts defined as lifting equipment, serving defined landing levels, having a car, the interior of which is regarded as inaccessible to persons on account of its dimensions and means of construction, suspended by ropes or chains or supported by a ram and moving between rigid vertical guide rails or guide rails whose inclination to the vertical does not exceed 15 degrees and driven electrically or hydraulically.

DocumentType
Standard
PublisherName
Ente Nazionale Italiano di Unificazione (UNI)
Status
Current
Supersedes

EN 12015:2014 Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Emission
EN 12016:2013 Electromagnetic compatibility - Product family standard for lifts, escalators and moving walks - Immunity
EN 50214:2006/corrigendum Dec. 2007 FLAT POLYVINYL CHLORIDE SHEATHED FLEXIBLE CABLES
HD 215 : 200S1 SAFETY REQUIREMENTS FOR INDICATING AND RECORDING ELECTRICAL MEASURING INSTRUMENTS AND THEIR ACCESSORIES
HD 214 : 200S2 RECOMMENDED METHOD FOR DETERMINING THE COMPARATIVE TRACKING INDEX OF SOLID INSULATING MATERIALS UNDER MOIST CONDITIONS
HD 384.4.41 S2:1996/A1:2002 ELECTRICAL INSTALLATIONS OF BUILDINGS - PART 4: PROTECTION FOR SAFETY - CHAPTER 41: PROTECTION AGAINST ELECTRIC SHOCK
EN 60249-2-3 : 1994 AMD 4 2000 BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 3: EPOXIDE CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET OF DEFINED FLAMMABILITY (VERTICAL BURNING TEST)
EN 60950:2000/corrigendum:2002 SAFETY OF INFORMATION TECHNOLOGY EQUIPMENT
HD 384.6.61 : 200S2 ELECTRICAL INSTALLATIONS OF BUILDINGS - VERIFICATION - INITIAL VERIFICATION
HD 213 : 200S1
EN 1050 : 1996 SAFETY OF MACHINERY - PRINCIPLES FOR RISK ASSESSMENT
EN 81-1:1998+A3:2009 Safety rules for the construction and installation of lifts - Part 1: Electric lifts
EN ISO 13857:2008 Safety of machinery - Safety distances to prevent hazard zones being reached by upper and lower limbs (ISO 13857:2008)
IEC 60747-5:1992 Semiconductor devices - Discrete devices and integrated circuits -Part 5: Optoelectronic devices
EN 60742:1995 Isolating transformers and safety isolating transformers - Requirements
EN 60249-2-2 : 1994 AMD 5 2000 BASE MATERIALS FOR PRINTED CIRCUITS - PART 2: SPECIFICATIONS - SPECIFICATION NO. 2: PHENOLIC CELLULOSE PAPER COPPER-CLAD LAMINATED SHEET, ECONOMIC QUALITY
HD 21.1 : 200S4 CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V AND HAVING THERMOPLASTIC INSULATION - GENERAL REQUIREMENTS
EN 60068-2-27:2009 Environmental testing - Part 2-27: Tests - Test Ea and guidance: Shock
HD 224 : 200S1 REPLACED
EN 60947-4-1 : 2010 AMD 1 2012 LOW-VOLTAGE SWITCHGEAR AND CONTROLGEAR - PART 4-1: CONTACTORS AND MOTOR-STARTERS - ELECTROMECHANICAL CONTACTORS AND MOTOR-STARTERS (IEC 60947-4-1:2009/A1:2012)
HD 360 : S2 AMD 1 CIRCULAR RUBBER INSULATED LIFT CABLES FOR NORMAL USE
EN 81-2 : 1998 + A3 2009 SAFETY RULES FOR THE CONSTRUCTION AND INSTALLATION OF LIFTS - PART 2: HYDRAULIC LIFTS
ISO 13857:2008 Safety of machinery Safety distances to prevent hazard zones being reached by upper and lower limbs
HD 384.5.54 : 200S1 ELECTRICAL INSTALLATION OF BUILDINGS - SELECTION AND ERECTION OF ELECTRICAL EQUIPMENT - EARTHING ARRANGEMENTS AND PROTECTIVE CONDUCTORS
ISO 1219-1:2012 Fluid power systems and components — Graphical symbols and circuit diagrams — Part 1: Graphical symbols for conventional use and data-processing applications
EN 60068-2-29:1993 Environmental testing - Part 2: Tests - Test Eb and guidance: Bump
EN 60068-2-6:2008 Environmental testing - Part 2-6: Tests - Test Fc: Vibration (sinusoidal)
EN 62326-1:2002 Printed boards - Part 1: Generic specification
IEC 60664-1:2007 Insulation coordination for equipment within low-voltage systems - Part 1: Principles, requirements and tests
EN 131-1:2015 Ladders - Part 1: Terms, types, functional sizes
HD 21 PT4 : 200S2 POLYVINYL CHLORIDE INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 4: SHEATHED CABLES FOR FIXED WIRING

View more information
Sorry this product is not available in your region.

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.