• There are no items in your cart

09/30200844 DC : 0

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

BS EN 779 - PARTICULATE AIR FILTERS FOR GENERAL VENTILATION - DETERMINATION OF THE FILTRATION PERFORMANCE
Available format(s)

Hardcopy , PDF

Superseded date

04-30-2012

Language(s)

English

Foreword
Introduction
1 Scope
2 Normative references
3 Terms and definitions
4 Symbols and abbreviated terms
5 Requirements
6 Classification
7 Test rig and equipment
   7.1 Test conditions
   7.2 Test rig
   7.3 Aerosol generation
        7.3.1 DEHS Test Aerosol
        7.3.2 Neutralisation (conditioning) of aerosol
   7.4 Aerosol sampling system
   7.5 Flow measurement
   7.6 Particle counter
   7.7 Differential pressure measuring equipment
   7.8 Dust feeder
8 Qualification of test rig and apparatus
   8.1 Air velocity uniformity in the test duct
   8.2 Aerosol uniformity in the test duct
   8.3 Particle counter sizing accuracy
   8.4 Particle counter zero test
   8.5 Particle counter overload test
   8.6 100% efficiency test
   8.7 Zero% efficiency test
   8.8 Aerosol generator response time
   8.9 Pressure equipment calibration
   8.10 Pressure drop checking
   8.11 Dust feeder air flow rate
   8.12 Neutraliser
   8.13 Summary of qualification requirements
   8.14 Apparatus maintenance
9 Test materials
   9.1 Test air - cleanliness, temperature and
        humidity
   9.2 Test aerosol
   9.3 Loading dust
   9.4 Final filter
10 Test procedure
   10.1 Preparation of filter to be tested
   10.2 Initial pressure drop
   10.3 Initial efficiency
        10.3.1 Efficiency of discharged filter media
        10.3.2 Efficiency measurement
   10.4 Dust loading
        10.4.1 Dust loading procedure
        10.4.2 Arrestance
        10.4.3 Efficiency
        10.4.4 Average efficiency
        10.4.5 Dust holding capacity
11 Uncertainty calculation of the test results
12 Reporting
   12.1 General
   12.2 Summary
   12.3 Efficiency
   12.4 Pressure drop and air flow rate
   12.5 Arrestance and dust holding capacity
   12.6 Marking
Annex A (normative) - Electrostatic discharging test
        procedure
   A.1 General
   A.2 Test method for discharging of filter material
        A.2.1 Equipment
        A.2.2 Preparation of test samples
        A.2.3 Measurement of the filter medium efficiency
        A.2.4 Isopropanol test
   A.3 Expression of results
   A.4 Report
Annex B (informative) - Shedding from filters
   B.1 General
   B.2 Shedding
        B.2.1 Particle bounce
        B.2.2 Release of fibres or particulate matter
               from filter material
        B.2.3 Re-entrainment of particles
   B.3 Testing
   B.4 References
Annex C (informative) - Commentary
   C.1 General
   C.2 Classification
   C.3 Test
        C.3.1 Test aerosol
        C.3.2 Loading dust
        C.3.3 Distribution and sampling of aerosols
        C.3.4 Particle counter characteristics
        C.3.5 Flat sheet test
   C.4 Filtration characteristics
        C.4.1 General
        C.4.2 Pressure drop
        C.4.3 Discharged efficiency
Annex D (informative) - Pressure drop calculation
Annex E (informative) - Example of a completed test report
   E.1 Example of test reports
   E.2 Examples of calculations
   E.3 Final results at 450 Pa
Bibliography

BS EN 779

Committee
MCE/21/3
DocumentType
Draft
Pages
72
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
PREN 779 : DRAFT 2009 Identical

ASHRAE 52.1 : 0 GRAVIMETRIC AND DUST SPOT PROCEDURES FOR TESTING AIR CLEANING DEVICES USED IN GENERAL VENTILATION FOR REMOVING PARTICULATE MATTER
ASHRAE 52.2 : 2017 METHOD OF TESTING GENERAL VENTILATION AIR-CLEANING DEVICES FOR REMOVAL EFFICIENCY BY PARTICLE SIZE
ISO 2854:1976 Statistical interpretation of data — Techniques of estimation and tests relating to means and variances
NFX 44 060 : 1993 AIR CLEANING EQUIPMENT - OIL MUST GAS PURIFIERS WITH INTEGRAL FAN FOR SCREW-CUTTING INDUSTRY - TEST METHOD
EN 779:2012 Particulate air filters for general ventilation - Determination of the filtration performance
EN ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full - Part 1: General principles and requirements (ISO 5167-1:2003)
ISO 5167-1:2003 Measurement of fluid flow by means of pressure differential devices inserted in circular cross-section conduits running full Part 1: General principles and requirements
EN 1822-3:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 3: Testing flat sheet filter media
EN 1822-1:2009 High efficiency air filters (EPA, HEPA and ULPA) - Part 1: Classification, performance testing, marking
ISO 12103-1:2016 Road vehicles — Test contaminants for filter evaluation — Part 1: Arizona test dust

View more information
US$23.96
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.