• There are no items in your cart

AS 1604-1997

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Timber - Preservative-treated - Sawn and round

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Published date

01-01-1997

Preview

1 - AS 1604-1997 TIMBER-PRESERVATIVE-TREATED-SAWN AND ROUND
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - 1 SCOPE
7 - 2 APPLICATION
7 - 3 LIMITATIONS
8 - 4 REFERENCED DOCUMENTS
8 - 5 DEFINITIONS
8 - 5.1 Brand
8 - 5.2 Natural durability
9 - 5.3 Hazard class number
9 - 5.4 Lyctid-susceptible sapwood
9 - 5.5 Pack-marking
9 - 5.6 Parcel
9 - 5.7 Penetration
9 - 5.8 Penetration zone
9 - 5.9 Preservative
9 - 5.10 Preservative number
9 - 5.11 Preservative-treated timber
9 - 5.12 Preservative treatment plant number
9 - 5.13 Retention
9 - 5.14 Timber
9 - 5.15 Treater
9 - 6 TIMBER PRESERVATIVE
9 - 7 SELECTION OF HAZARD CLASS NUMBER
13 - 8 PRESERVATIVE TREATMENT
13 - 8.1 General
13 - 8.2 Penetration requirement
13 - 8.3 Penetration compliance
13 - 8.4 Retention of preservative
13 - 8.4.1 General
13 - 8.4.2 Retention requirements
13 - 8.4.3 Hazard class 1
13 - 8.4.4 Hazard classes 2 to 6
13 - 8.5 Retention compliance
13 - 8.6 Branding
15 - 9 HAZARD CLASS 1
15 - 9.1 General
15 - 9.2 Preservative penetration zone
15 - 9.3 Preservative retention requirement
17 - 10 HAZARD CLASS 2
17 - 10.1 General
17 - 10.2 Preservative penetration zone
17 - 10.3 Preservative retention requirement
19 - 11 HAZARD CLASS 3
19 - 11.1 General
19 - 11.2 Preservative penetration zone
19 - 11.3 Preservative retention requirement
21 - 12 HAZARD CLASS 4
21 - 12.1 General
21 - 12.2 Preservative penetration zone
21 - 12.3 Preservative retention requirement
23 - 13 HAZARD CLASS 5
23 - 13.1 General
23 - 13.2 Preservative penetration zone
23 - 13.3 Preservative retention zone
25 - 14 HAZARD CLASSES 6 AND 6SW
25 - 14.1 General
25 - 14.2 Preservative penetration zone
26 - 14.3 Preservative retention requirement
27 - 15 MARKING
27 - 15.1 Legible marking
27 - 15.2 Marking information
27 - 15.3 Numerical layout of brands
27 - 15.4 Exemptions from marking
27 - 16 CERTIFICATE OF TREATMENT
28 - APPENDIX A - HARDWOODS NOT SUSCEPTIBLE TO LYCTID ATTACK
28 - A1 SCOPE AND GENERAL
28 - A2 CHEMICALTEST
30 - APPENDIX B - DESCRIPTION OF PRESERVATIVES FOR USE IN THIS STANDARD
30 - B1 SCOPE
30 - B2 CATEGORIES
30 - B3 OIL-BORNE PRESERVATIVES
30 - B4 WATERBORNE PRESERVATIVES
31 - B5 LIGHT ORGANIC SOLVENT-BORNE PRESERVATIVES
32 - APPENDIX C - MARKING CODES
34 - APPENDIX D - GUIDE TO HAZARD CLASSIFICATIONS FOR VARIOUS END USE APPLICATIONS
36 - APPENDIX E - METHOD OF SELECTION AND PREPARATION OF TEST SPECIMEN
36 - E1 SCOPE
36 - E2 SAMPLING PRESERVATIVE-TREATED TIMBER
36 - E3 PREPARATION OF TEST SAMPLE
37 - APPENDIX F - THE NATURAL DURABILITY OF COMMERCIAL TIMBERS
37 - F1 INTRODUCTION
37 - F2 PURPOSE
37 - F3 CATEGORIES

This Standard specifies requirements for preservative-treated sawn and round timber for protection against decay, insect or marine borer attack. It incorporates borate treatment for hazard class 2, TBTN/permethrin treatment for hazard class 3, and ammoniacal copper quaternary (ACQ) for hazard classes 1 and 3 for hardwood and hazard classes 2 to 5 for softwood. This revision omits the equivalent retention levels of individual pieces expressed on a mass/volume basis. The description of the newly included preservatives is added into relevant clauses and Appendix B. Appendix C provides information on the allocation and registration of treatment plant numbers and preservative code numbers.

This Standard specifies requirements for preservative-treated sawn and round timber that is required to be protected against decay, insect or marine borer attack for all exposure conditions throughout Australia, with limitations described in Clause 3. This Standard does not cover grade or seasoning condition.

Committee
TM-006
DocumentType
Standard
ISBN
0 7337 1052 2
Pages
27
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Amendment 1 to AS 1604-1997 see DR 97586 CP. Under Revision see DR 98476 CP First published in part as INT 91-1945.INT 92 first published 1945.AS O60 first published 1956.INT 91-1945 and INT 92-1945 revised, amalgamated and redesignated AS 1604-1974.AS O60-1956 and AS 1604-1974 revised, amalgamated and designated AS 1604-1980.Third edition 1993.Fourth edition 1997. First published in part as INT 91-1945. INT 92 first published 1945. AS O60 first published 1956. INT 91-1945 and INT 92-1945 revised, amalgamated and redesignated AS 1604-1974. AS O60-1956 and AS 1604-1974 revised, amalgamated and designated AS 1604-1980. Third edition 1993. Fourth edition 1997.

AS 1399-1990 Guide to AS 1199 - Sampling procedures and tables for inspection by attributes
AS 2209-1994 Timber - Poles for overhead lines
AS 1199-1988 Sampling procedures and tables for inspection by attributes
AS 1143-1973 High temperature creosote for the preservation of timber
AS O1-1964 Glossary of terms used in timber Standards
AS 1605-1974 Methods for the sampling and analysis of wood preservatives and preservative-treated wood
AS 3530-1988 Solvents - Mineral turpentine and white spirit

AS 1157.5-1998 Methods of testing materials for resistance to fungal growth Resistance of timber to surface fungal growth
AS/NZS 1605:1998 Methods for sampling and analysing timber preservatives and preservative-treated timber
AS 1720.2-1990 Timber structures Timber properties
AS 3660.3-2000 Termite management Assessment criteria for termite management systems
AS 4219-1994 Timber - Stumps and sole plates
AS/NZS 1328.2:1998 Glued laminated structural timber Guidelines for AS/NZS 1328: Pt 1 for the selection, production and installation of glued laminated structural timber
AS 2159-1995 Piling - Design and installation
AS 3660.1-1995 Protection of buildings from subterranean termites - New buildings
AS 2047-1999 Windows in buildings - Selection and installation
AS 1684-1992 National Timber Framing Code
AS/NZS 3500.1.2:1998 National plumbing and drainage Water supply - Acceptable solutions
AS/NZS 2272:1996 Plywood - Marine
AS/NZS 3500.4.2:1997 National Plumbing and Drainage Hot water supply systems - Acceptable solutions
AS 2689-1984 Timber doorsets
AS/NZS 3500.2.2:1996 National plumbing and drainage Sanitary plumbing and drainage - Acceptable solutions
AS 3519-1993 Timber - Machine proof-grading
AS 1892.2-1992 Portable ladders Timber (Reconfirmed 2022)
AS/NZS 1748:1997 Timber - Stress-graded - Product requirements for mechanically stress-graded timber
AS 2688-1984 Timber doors
AS 3500.1-1992 National Plumbing and Drainage Code - Water supply
AS 2400.7-1990 Packaging Timber boxes
AS 1657-1992 Fixed platforms, walkways, stairways and ladders - Design, construction and installation
AS 2209-1994 Timber - Poles for overhead lines
AS/NZS 2269:1994 Plywood - Structural
AS/NZS 1605:2000 Methods for sampling and analysing timber preservatives and preservative-treated timber
AS 2047.1-1996 Windows in buildings - Specification for materials and performance
AS 1577-1993 Scaffold planks
AS/NZS 4357:1995 Structural Laminated Veneer Lumber
AS 2858-2001 Timber - Softwood - Visually graded for structural purposes
AS/NZS 3845:1999 Road safety barrier systems
AS 2796.3-1999 Timber - Hardwood - Sawn and milled products Timber for furniture components
AS 3818.4-2000 Timber - Heavy structural products - Visually graded Cross-arms for overhead lines
AS 3818.3-2001 Timber - Heavy structural products - Visually graded Piles
AS/NZS 3500.5:2000 National Plumbing and Drainage - Domestic installations
AS 3500.4-1994 National Plumbing and Drainage Code Hot water supply systems
AS 1720.1-1997 Timber structures Design methods
AS 3818.1-1998 Timber - Heavy structural products - Visually graded General requirements
AS/NZS 2271:1999 Plywood and blockboard for exterior use
AS/NZS 2270:1999 Plywood and blockboard for interior use
AS 2311-1992 The painting of buildings
AS 4285-1995 Skylights
AS 3660.1-2000 Termite management New building work
AS 2796.1-1999 Timber - Hardwood - Sawn and milled products Product specification (Reconfirmed 2016)
AS 1417.1-1987 Receiving antennas for radio and television in the frequency range 30 MHz to 1 GHz - Construction and installation
AS 3660.2-2000 Termite management In and around existing buildings and structures - Guidelines
AS 3660-1993 Protection of buildings from subterranean termites - Prevention, detection and treatment of infestation
WS13-2012 Finishing Timber Externally
AS/NZS 2311:2000 Guide to the painting of buildings
AS 2159 SUPP 1-1996 Piling - Design and installation - Guidelines (Supplement to AS 2159 - 1995) (Reconfirmed 2018)
AS 2082-2000 Timber - Hardwood - Visually stress-graded for structural purposes
AS 1909-1984 Installation of timber doorsets
AS/NZS 3500.3.2:1998 National plumbing and drainage Stormwater drainage - Acceptable solutions

View more information
US$82.57
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.