• There are no items in your cart

AS 1684.4-2006

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Residential timber-framed construction - Simplified - Non-cyclonic areas (SEE IMPORTANT NOTE)
Available format(s)

Hardcopy , Hardcopy with incorporated amendment , Looseleaf with incorporated amendment with Binder , Hardcopy Looseleaf , Hardcopy Looseleaf with Binder , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-23-2023

Published date

01-01-2006

Preview

Important Note:

This is a traditional bound edition of the new AS 1684.4-2006.

If you have a loose-leaf edition of the 1999 Standard, and just want to replace the contents, click here

If you want a loose-leaf edition plus a convenient binder, click here.

Specifies requirements for building practice and for the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class 1 and Class 10 buildings, as defined in the Building Code of Australia, for non-cyclonic wind classifications N1 and N2.

This Standard specifies requirements for building practice and for the selection, placement and fixing of the various structural elements used in the construction of timber-framed Class1 and Class10 Buildings as defined by the Building Code of Australia and within the limitations given in Clause1.4. The provisions of the Standard also apply to alterations and additions to these buildings.This Standard also provides building practice and procedures that assist in the correct specification and determination of timber members, bracing and connections, thereby minimizing the risk of creating an environment that may adversely affect the ultimate performance of the structure.This Standard may also be applicable to the design and construction of other classes of buildings where the design criteria, loadings and other parameters applicable to those classes of building are within the limitations of this Standard.NOTES:1 See AS1684.1 for details of design criteria, loadings and other parameters.2 Whilst this Standard may be used to design Class10 buildings, less conservative levels of design for this building class may be permitted by building regulations and other Australian Standards. Member Span Tables are given in AppendixA.

Committee
TM-002
DocumentType
Standard
ISBN
0 7337 7097 5
Pages
194
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS O56-1946.Second edition 1948.Revised and redesignated as AS CA38-1971.Revised and redesignated as AS 1684-1975.Second edition 1979.Third edition 1992.Revised and redesignated in part as AS 1684.4-1999.Second edition 2006. First published as AS 056-1946. Second edition 1948. Revised and redesignated as AS CA38-1971. Revised and redesignated as AS 1684-1975. Third edition 1992. Revised and redesignated in part as AS 1684.4-1999. Second edition 2006.

AS 1170.4-1993 Minimum design loads on structures (known as the SAA Loading Code) Earthquake loads
AS/NZS 1604.4:2004 Specification for preservative treatment - Laminated veneer lumber (LVL)
AS 1860-1998 Installation of particleboard flooring
AS/NZS 1860.1:2002 Particleboard flooring Specifications
AS 1397-2001 Steel sheet and strip - Hot-dipped zinc-coated or aluminium/zinc-coated
AS/NZS 1859.4:2004 Reconstituted wood-based panels - Specifications Wet-processed fibreboard
AS/NZS 1604.3:2004 Specification for preservative treatment - Plywood
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS/NZS 2269:2004 Plywood - Structural
AS 4785.1-2002 Timber - Softwood - Sawn and milled products Product specification (Reconfirmed 2016)
AS 1684.2-2006 Residential timber-framed construction Non-cyclonic areas (SEE IMPORTANT NOTE)
AS/NZS 1604.2:2004 Specification for preservative treatment - Reconstituted wood-based products
AS/NZS 4791:1999 Hot-dip galvanized (zinc) coatings on ferrous open sections, applied by an in-line process
AS 2870-1996 Residential slabs and footings - Construction
AS 1684.1-1999 Residential timber-framed construction Design criteria
AS 4055-2006 Wind loads for housing
AS 1604.1-2005 Specification for preservative treatment - Sawn and round timber
AS/NZS 2918:2001 Domestic solid fuel burning appliances - Installation
AS 2796.1-1999 Timber - Hardwood - Sawn and milled products Product specification (Reconfirmed 2016)
AS 5604-2005 Timber - Natural durability ratings (Reconfirmed 2016)
AS 1720.1-1997 Timber structures Design methods
AS 1684.3-2006 Residential timber-framed construction Cyclonic areas
AS 1810-1995 Timber - Seasoned cypress pine - Milled products
AS/NZS 1604.5:2005 Specification for preservative treatment - Glued laminated timber products
AS 1214-1983 Hot-dip galvanized coatings on threaded fasteners (ISO metric coarse thread series)
AS/NZS 1170.2:2002 Structural design actions Wind actions
AS 4440-2004 Installation of nailplated timber roof trusses
AS 1691-1985 Domestic oil-fired appliances - Installation

AS 1684.2-2010 Residential timber-framed construction Non-cyclonic areas
HB 52-2000 The Bathroom Book
AS/NZS 2455.2:2007 Textile floor coverings - Installation practice - Carpet tiles
AS/NZS 2455.1:2007 Textile floor coverings - Installation practice General
AS 3958.1-2007 Ceramic tiles Guide to the installation of ceramic tiles
AS 1684.2-2006 Residential timber-framed construction Non-cyclonic areas (SEE IMPORTANT NOTE)
AS 3700-2001 Masonry structures
AS 4654.2-2009 Waterproofing membrane systems for exterior use - Above ground level Design and installation
AS 3740-2004 Waterproofing of wet areas within residential buildings
AS 2082-2007 Timber - Hardwood - Visually stress-graded for structural purposes (Reconfirmed 2017)
HB 52-2000 The Bathroom Book
AS/NZS 2589:2007 Gypsum linings - Application and finishing
AS 1860.2-2006 Particleboard flooring Installation (Reconfirmed 2016)
AS/NZS 1748:2006 Timber - Mechanically stress-graded for structural purposes
AS 1562.3-2006 Design and installation of sheet roof and wall cladding Plastic (Reconfirmed 2018)
AS 1170.4-2007 Structural design actions Earthquake actions in Australia (Reconfirmed 2018)
AS 1684.3-2006 Residential timber-framed construction Cyclonic areas

View more information
US$69.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.