Power Transformers Ability To Withstand Short-Circuit

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-17-2018

Language(s)

English

Published date

08-09-1982

1 - AS 2374, Part 5-1982 POWER TRANSFORMERS - ABILITY TO WITHSTAND SHORT-CIRCUIT
4 - PREFACE
4 - CONTENTS
5 - SECTION 1. SCOPE AND DEFINITIONS
5 - 1.1 SCOPE.
5 - 1.2 DEFINITIONS.
6 - SECTION 2. REQUIREMENTS WITH REGARD TO ABILITY TO WITHSTAND SHORT-CIRCUIT
6 - 2.1 GENERAL.
6 - 2.2 OVERCURRENT CONDITIONS.
6 - 2.2.1 Transformers with Two Separate Windings.
6 - 2.2.2 Transformers with more than Two Windings and Autotransformers
7 - 2.2.3 Booster Transformers.
7 - 2.2.4 Transformers Directly Associated with Other Apparatus
7 - 2.2.5 Special Transformers.
7 - 2.2.6 Tap-changing Equipment.
7 - 2.2.7 Neutral Terminals.
8 - SECTION 3. DEMONSTRATION OF ABILITY TO WITHSTAND SHORT-CIRCUIT
8 - 3.1 THERMAL ABILITY TO WITHSTAND SHORT-CIRCUIT.
8 - 3.1.1 General.
8 - 3.1.2 Value of the Symmetrical Short-circuit Current I for Transformers with Two Windings
8 - 3.1.3 Duration of the Symmetrical Short-circuit Current I
8 - 3.1.4 Maximum Permissible Value of the Highest Average Temperature
8 - 3.1.5 Calculation of the Temperature
8 - 3.1.6 Value of the Symmetrical Short-circuit Current I for Transformers with more than Two Windings and Autotransformers
9 - 3.2 DYNAMIC ABILITY TO WITHSTAND SHORT-CIRCUIT.
9 - 3.2.1 General.
9 - 3.2.2 Condition of the Transformer before the Short-circuit Tests.
9 - 3.2.3 Peak Value l^ for Two-winding Transformers.
9 - 3.2.4 Value and Duration of the Short-circuit Test Current for Two-windings Transformers
10 - 3.2.5 Short-circuit Testing Procedure for Transformers with Two Windings.
10 - 3.2.6 Detection of Faults.
12 - APPENDIX A - MODIFIED SHORT-CIRCUIT TEST PROCEDURES FOR CATEGORY I TRANSFORMERS

Specifies the design of power transformers as defined in AS 2374.1, and the requirements necessary both in regard to their ability to withstand short-circuit and the means of demonstrating that ability. Based on IEC 76-5.

This standard specifies the design of power transformers as defined in AS 2374, Part 1, and the requirements necessary both in regard to their ability to withstand short-circuit and the means of demonstrating that ability.NOTES:1. Pending the publication of a standard that applies to dry-type transformers*, the requirements of this standard may be applied to dry-type transformers subject to agreement between the purchaser and the manufacturer and taking into account the principles established in Sections 2 and 3.2. A reduced schedule of short-circuit tests may be applied to Category I transformers by agreement between purchaser, manufacturer and testing authority. Guidance on the reduced schedule is given in Appendix A.

Committee
EL-008
DocumentType
Standard
ISBN
0 7262 2641 6
Pages
8
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Reconfirmed 1987

AS 60146.1.1-2002 Semiconductor converters General requirements and line commutated converters - Specifications of basic requirements
AS/NZS 2081.5:2002 Electrical equipment for coal and shale mines - Electrical protection devices - Earth-fault current limiters
AS 60076.1-2005 Power transformers General (IEC 60076-1, Ed. 2.1 (2000) MOD)
AS 2735-1984 Dry-type power transformers
AS 2832.1-2004 Cathodic protection of metals Pipes and cables
AS 1265-1990 Bushings for alternating voltages above 1000 V
AS/NZS 60137:2008 Insulated bushings for alternating voltages above 1000 V (IEC 60137, Ed. 5.0 (2003) MOD)
AS 2326.2-1991 On-load tap-changers - Application guide
AS/NZS 2081:2011 Electrical protection devices for mines and quarries (Reconfirmed 2022)
AS 2374.1-1997 Power transformers General
AS/NZS 4871.3:2002 Electrical equipment for coal mines, for use underground Substations
AS 61800.2-2004 Adjustable speed electrical power drive systems General requirements - Rating specifications for low voltage adjustable frequency a.c. power drive systems
AS 2832.2-2003 Cathodic protection of metals Compact buried structures
AS 61330-2005 High-voltage/low-voltage prefabricated substations
AS 2374.7-1997 Power transformers - Loading guide for oil-immersed power transformers
AS/NZS 4871.3:2010 Electrical equipment for mines and quarries Substations
AS 1028-1992 Power reactors and earthing transformers

View more information
US$34.90
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.