AS 3007.1-1987

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electrical installations - Surface mines and associated processing plant - Scope and definitions
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-28-2023

Language(s)

English

Published date

01-01-1987

1 - AS 3007.1-1987 ELECTRICAL INSTALLATIONS-SURFACE MINES AND ASSOCIATED PROCESSING PLANT - SCOPE AND DEFINITIONS
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE AND REFERENCED DOCUMENTS.
6 - 1.1 Scope.
6 - 1.2 Referenced documents.
6 - 2 OBJECT.
6 - 3 DEFINITIONS.
6 - 3.1 Open-cut mine (open-cast mine)
6 - 3.2 Quarry
6 - 3.3 Electrical installation
6 - 3.4 Electrical equipment
6 - 3.5 Operating area (normal operating area)
7 - 3.6 Electrical operating area
7 - 3.7 Closed electrical operating area
7 - 3.8 Ordinary persons
7 - 3.9 Instructed persons
7 - 3.10 Skilled persons
7 - 3.11 Winning and stacking machinery
7 - 3.12 Transport conveying system
7 - 3.13 Primary processing machinery
7 - 3.14 Secondary processing machinery
7 - 3.15 Haulage truck
7 - 3.16 Portable apparatus
7 - 3.17 Mobile apparatus
7 - 3.18 Movable apparatus
7 - 3.19 Fixed apparatus
7 - 3.20 Self-contained power supply
7 - 3.21 External power supply
7 - 3.22 TN system
7 - 3.23 TT system
7 - 3.24 IT system
7 - 3.25 Live part
7 - 3.26 Exposed conductive part
7 - 3.27 Extraneous conductive part
7 - 3.28 Direct contact
8 - 3.29 Indirect contact
8 - 3.30 Arm’s reach
8 - 3.31 Barrier (screen)
8 - 3.32 Enclosure
8 - 3.33 Obstacle
8 - 3.34 Protective systems and devices
8 - 3.35 Fault current
8 - 3.36 Earth fault current
8 - 3.37 Leakage current (in an installation)
8 - 3.38 Residual current
8 - 3.39 Nominal voltage (of a three-phase system)
8 - 3.40 Highest voltage (of a three-phase system)
8 - 3.41 Touch voltage
8 - 3.42 Prospective touch voltage
8 - 3.43 Conventional touch voltage limit (symbol UL)
8 - 3.44 Protective conductor (symbol PE)
8 - 3.45 Neutral conductor (symbol N)
8 - 3.46 PEN conductor
8 - 3.47 Equipotential bonding conductor
8 - 3.48 Equipotential bonding
8 - 3.49 Earthable point
8 - 3.50 Earthing conductor
8 - 3.51 Main earthing terminal (main earthing bar)
8 - 3.52 Earth electrode
8 - 3.53 Insulation monitoring device
8 - 3.54 Safety circuits and devices
9 - 3.55 Movable distribution cable
9 - 3.56 Reeling (drum) cable
9 - 3.57 Trailing cable
9 - 3.58 Armour (of a cable)
9 - 3.59 Overhead line
9 - 3.60 Overhead distribution line (feeder)
9 - 3.61 Overhead traction (trolley wire)
9 - 3.62 Overhead traction distribution line (feeder)
9 - 3.63 Overhead collector wire
9 - 3.64 Continuous duty
9 - 3.65 Periodic or cyclic duty
10 - APPENDIX A - INDEX OF TERMS
11 - ANNEX - SUMMARY OF TECHNICAL DEVIATIONS BETWEEN THIS STANDARD AND IEC 621-1

Sets out the scope of the AS 3007 series of Standards and provides definitions for some of the terms used. Technically equivalent to IEC 621-1.

This standard (and other standards in the AS 3007 series) applies to the installation and operation of electrical apparatus and systems associated with outdoor sites under heavy conditions, including open-cast mines, quarries, stockpiles and the like. It applies particularly to electrical apparatus and systems used for the following: (a) Winning, stacking and primary processing machinery.(b) Secondary processing machinery.(c) Transport conveying systems.(d) Pumping and water supply systems.(e) Power generating and distribution equipment.(f) Control, signal, supervisory and communication systems.(g) Ancillaries.The AS 3007 series does not cover temporary and provisional places of work in the open, such as building sites and earth-moving sites, unless the equipment used is similar to that used in surface mining applications.

Committee
EL-033
DocumentType
Standard
ISBN
0 7262 4613 1
Pages
6
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 60621-1:1987 Identical

AS 2264-1995 A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV
AS/NZS 4871.6:2013 Electrical equipment for mines and quarries Diesel powered machinery and ancillary equipment
AS/NZS 2802:2000 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining) (Reconfirmed 2020)
AS 1418.1-2002 Cranes, hoists and winches General requirements
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2802-1992 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)
AS 2802-1992 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)
AS 1418.1-1994 Cranes (including hoists and winches) - General requirements

View more information