Method for sampling and analysis of ambient air - Part 9.8: Determination of suspended particulate matter - PM(sub)10(/sub) continuous direct mass method using a tapered element oscillating microbalance analyser

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

05-17-2018

Language(s)

English

Published date

01-01-2001

Preview

1 - AS 3580.9.8-2001 METHODS FOR SAMPLING AND ANALYSIS OF AMBIENT AIR - DETERMINATION OF SUSPENDED PARTICULATE MATTER-PM10 CONTIN
1 - PREFACE
1 - FOREWORD
2 - METHOD
2 - 1 SCOPE
2 - 2 REFERENCED DOCUMENTS
2 - 3 DEFINITIONS
2 - 3.1 Equivalent aerodynamic diameter (EAD)
2 - 3.2 PM10
2 - 4 PRINCIPLE
6 - 5 APPARATUS
6 - 5.1 Analyser
6 - 5.2 Analytical balance
6 - 5.3 Sample filters
7 - 5.4 Size-selective inlet
7 - 5.5 Reference barometer
7 - 5.6 Reference flow meter
7 - 5.7 Reference thermometer
7 - 5.8 Chart recorder
7 - 6 CALIBRATION
7 - 6.1 Mass transducer calibration verification
8 - 6.2 Flow controller calibration
8 - 6.3 Ambient temperature calibration
8 - 6.4 Ambient pressure calibration
9 - 7 SAMPLING
9 - 7.1 Sampling site
9 - 7.2 Sampling temperature
10 - 7.3 Flow rate
10 - 7.4 Averaging time
10 - 8 PROCEDURE
11 - 9 DATA VALIDATION
11 - 10 CALCULATION AND EXPRESSION OF RESULTS
12 - 11 PRECISION
12 - 12 REPORT
13 - 13 BIBLIOGRAPHY

Sets out a method of operating the tapered element oscillating microbalance (TEOM) analyzer to determine suspended particulate matter in ambient air. The method allows continuous oepration, providing near real-time measurements of mean particle concentration over periods from 10 minutes to 24 hours.

This Standard sets out a method for the continuous determination of suspended particulate matter in ambient air using a tapered element oscillating microbalance (TEOM) analyser. The method can provide a measure of mean particle concentration over periods from 10 minutes to 24 hours. The moving 10-minute mean is updated every 2 seconds, whereas the 24-hour mean mass concentration is updated every 60 minutes on the hour. Results are normally reported as 24-hour, time-integrated mean values.

Committee
EV-007
DocumentType
Standard
ISBN
0 7337 3771 4
Pages
12
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

First published as AS 3580.9.8-2001.

AS 3580.9.6-1990 Methods for sampling and analysis of ambient air Determination of suspended particulate matter - PM(sub)10(/sub) high volume sampler with size-selective inlet - Gravimetric method
AS 2922-1987 Ambient air - Guide for the siting of sampling units

AS/NZS 3580.1.1:2007 Methods for sampling and analysis of ambient air Guide to siting air monitoring equipment

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.