• There are no items in your cart

AS 3772-1990

Superseded

Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Fire protection of cooking areas

Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Published date

01-01-1990

Preview

1 - AS 3772-1990 FIRE PROTECTION OF COOKING AREAS
4 - PREFACE
5 - CONTENTS
6 - SECTION 1 SCOPE AND GENERAL
6 - 1.1 SCOPE.
6 - 1.2 REFERENCED DOCUMENTS.
7 - 1.3 DEFINITIONS.
7 - 1.3.1 Extinguishant
7 - 1.3.2 Wet chemical extinguishing agent
7 - 1.3.3 Approved
7 - 1.3.4 Fire extinguishing powder
7 - 1.3.5 Standard systems
7 - 1.3.6 Pre-engineered systems
7 - 1.3.7 Custom designed systems
7 - 1.4 PERSONNEL.
7 - 1.5 HEALTH AND SAFETY.
7 - 1.6 GENERAL FIRE PROTECTION REQUIREMENTS.
7 - 1.6.1 Hoods and ducting.
7 - 1.6.2 Portable fire extinguishers.
7 - 1.6.3 Fire blankets.
7 - 1.6.4 Fire detectors.
7 - 1.6.5 Hose reels.
7 - 1.6.6 Fire hydrants.
8 - SECTION 2 COMMON DESIGN AND INSTALLATION REQUIREMENTS FOR FIXED FIRE EXTINGUISHING SYSTEMS
8 - 2.1 DESIGN AND CONSTRUCTION.
8 - 2.1.1 Coverage.
8 - 2.1.2 Control system.
9 - 2.1.3 Pipes and fittings.
9 - 2.2 DISCHARGE NOZZLES.
9 - 2.2.1 Location.
9 - 2.2.2 Strength.
9 - 2.2.3 Material.
9 - 2.2.4 Installation.
9 - 2.2.5 Marking.
9 - 2.2.6 Protection.
9 - 2.3 SYSTEM DETECTORS.
9 - 2.3.1 Types.
9 - 2.3.2 Location.
9 - 2.4 INDICATORS.
9 - 2.5 SYSTEMS PROTECTING SHARED PLENUMS.
9 - 2.6 QUANTITY OF EXTINGUISHANT.
10 - 2.7 EXTINGUISHANT STORAGE CONTAINERS.
10 - 2.8 PRELIMINARY DATA AND SPECIFICATIONS.
10 - 2.9 PRE-ENGINEERED SYSTEMS.
10 - 2.10 DRAWINGS.
10 - 2.11 SYSTEM MANUALS.
10 - 2.12 SAFETY WARNINGS
11 - SECTION 3 CARBON DIOXIDE SYSTEMS
11 - 3.1 GENERAL.
11 - 3.2 HEALTH AND SAFETY.
11 - 3.3 LOCATION OF NOZZLES AND QUANTITY OF DISCHARGE.
12 - SECTION 4 FIRE EXTINGUISHING POWDER SYSTEMS
12 - 4.1 GENERAL.
12 - 4.1.1 Composition.
12 - 4.1.2 Monoammonium phosphate extinguishing powder.
12 - 4.2 HEALTH AND SAFETY.
12 - 4.2.1 General.
12 - 4.2.2 Warning signs.
12 - 4.3 RATE AND DURATION OF DISCHARGE.
12 - 4.4 ARRANGEMENT OF PIPEWORK.
14 - SECTION 5 WET CHEMICAL SYSTEMS
14 - 5.1 GENERAL.
14 - 5.2 HEALTH AND SAFETY.
14 - 5.2.1 General.
14 - 5.2.2 Warning signs.
14 - 5.3 RATE AND DURATION OF DISCHARGE.
14 - 5.4 SYSTEM FLUSHING
15 - SECTION 6 SPRINKLER AND WATER SPRAY SYSTEMS
15 - 6.1 GENERAL.
15 - 6.2 HEALTH AND SAFETY.
15 - 6.2.1 General.
15 - 6.2.2 Warning signs.
15 - 6.3 RATE AND DURATION OF DISCHARGE.
16 - APPENDIX A - EXTINGUISHING SYSTEM PERFORMANCE REQUIREMENTS
16 - A1 GENERAL.
16 - A2 SIMULATED DEEP FRYER SPECIFICATIONS.
16 - A3 HOOD AND DUCT DIMENSIONS.
16 - A4 FUEL LOADING.
17 - A5 TEST METHODS.
17 - A5.1 Detector actuation.
17 - A5.2 Manual actuation.
17 - A6 PERFORMANCE REQUIREMENTS.
17 - A7 OBSERVATIONS DURING TEST.
18 - APPENDIX B - COMPONENT PERFORMANCE REQUIREMENTS
18 - B1 GENERAL.
18 - B2 EXTERNAL CORROSION.
18 - B3 CONTAINERS FOR EXTINGUISHING AGENTS AND EXPELLANT GASES.
18 - B3.1 Pressure tests.
18 - B3.2 Leakage tests.
18 - B4 EXTINGUISHING POWDER COMPACTION.
18 - B5 DETECTORS.
18 - B5.1 Fusible link detectors.
18 - B5.2 Glass bulb detectors.
18 - B5.3 Heat detectors.
18 - B5.4 Line detectors.
18 - B5.5 Other detector types.
18 - B6 NOZZLE FIRE EXPOSURE.
19 - B7 REPORTING.
20 - APPENDIX C - INSPECTION, MAINTENANCE, AND RECORDS
20 - C1 COPE.
20 - C2 BASIS OF SYSTEM.
20 - C3 MAINTENANCE LEVEL 1.
20 - C4 MAINTENANCE LEVEL 2.
20 - C5 MAINTENANCE LEVEL 3.
20 - C6 MAINTENANCE LEVEL 4.
20 - C7 MAINTENANCE TAGS.
21 - C8 RECORDS.

Specifies ancillary fire protection equipment such as portable fire-extinguishers and fire blankets, but is principally concerned with performance specifications for fixed fire-extinguishing systems utilizing carbon dioxide, extinguishing powders, wet chemicals, or water sprays. Minimum requirements for inspection and maintenance are also given herein.

This Standard sets out requirements for the safety, design, installation, testing and maintenance of fixed fire extinguishing systems used in kitchens (fixed, relocatable, or mobile) and other cooking areas.Such systems comprise the following:(a) Standard systems.(b) Pre-engineered systems.(c) Custom designed systems.This Standard applies to unenclosed cooking appliances employed in restaurant, commercial, industrial, and institutional situations, and which may have an open surface of cooking oil or fat e.g. deep fryers, griddles, grillers, range tops, etc. This Standard also applies to hoods and ducts associated with such appliances.Enclosed ovens, water boilers, etc., are excluded from the requirements of this Standard. Requirements for inspection and maintenance are specified in Appendix C.

Committee
FP-011
DocumentType
Standard
ISBN
0 7262 6158 0
Pages
16
ProductNote
This Standard is under revision.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Obsolescent 23-08-2005

AS 1841-1985 Portable fire extinguishers - Water (gas container) type
AS 1845-1985 Portable fire extinguishers - Foam (stored pressure) type
AS 2441-2005 Installation of fire hose reels (Reconfirmed 2018)
AS 2118-1982 Automatic fire sprinkler systems (known as the SAA Code for Automatic Fire Sprinkler Systems)
AS 2030.1-1999 The verification, filling, inspection, testing and maintenance of cylinders for storage and transport of compressed gases Cylinders for compressed gases other than acetylene
AS 1848-1985 Portable fire extinguishers - Halon type
AS 1319-1994 Safety signs for the occupational environment (Reconfirmed 2018)
AS 2470-2005 Steel cylinders for compressed gases - Welded three-piece construction with longitudinal joint - 11 kg to 150 kg (Reconfirmed 2016)
AS 1851.1-1995 Maintenance of fire protection equipment - Portable fire extinguishers and fire blankets
AS 1846-1985 Portable fire extinguishers - Powder type
AS 1851.2-1995 Maintenance of fire protection equipment - Fire hose reels
AS 1603.2-1997 Automatic fire detection and alarm systems Point type smoke detectors (Reconfirmed 2016)
AS 1844-1985 Portable fire extinguishers - Foam (gas container) type
AS/NZS 3509:2003 LP Gas fuel vessels for automotive use
AS 1847-1985 Portable fire extinguishers - Carbon dioxide type
AS 1890-1999 Thermally released links (Reconfirmed 2016)
AS/NZS 1668.1:1998 The use of ventilation and airconditioning in buildings Fire and smoke control in multi-compartment buildings
AS 1603.1-1997 Automatic fire detection and alarm systems Heat detectors (Reconfirmed 2016)
AS 1842-1985 Portable fire extinguishers - Water and wet chemical (stored pressure) type
AS 2419.1-2005 Fire hydrant installations System design, installation and commissioning
AS/NZS 1221:1997 Fire hose reels (Reconfirmed 2020)
AS 2700-1996 Colour Standards for general purposes - Swatches
AS/NZS 3504:2006 Fire blankets (Reconfirmed 2019)
AS 1216-2006 Class labels for dangerous goods
AS 1851.4-1992 Maintenance of fire protection equipment - Fire hydrant installations

SAA HB20-1996 Graphical symbols for fire protection drawings (Reconfirmed 2018)
AS 1668.1-1991 The use of mechanical ventilation and air-conditioning in buildings - Fire and smoke control

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.