1 - AS 4060 Supp1:1992 LOADS ON BURIED VITRIFIED CLAY PIPES - COMMENTARY (SUPPLEMENT TO AS 4060:1992)
4 - PREFACE
5 - CONTENTS
6 - FOREWORD
7 - GENERAL
7 - C6 WORKING LOADS
7 - C6.1 Types
7 - C6.2 Data
7 - C6.3 Working loads due to trench fill, embankment fill or in-situ material
7 - C6.3.2 Narrow trench condition
9 - C6.3.3 Wide trench or embankment condition (positive projection)
9 - C6.3.4 Embankment condition (negative projection)
9 - C6.3.5 Settlement ratio
10 - C6.3.7 Multiple pipes
10 - C6.3.8 Jacked or bored pipes
10 - C6.4 Working loads due to superimposed dead loads
10 - C6.5 Working loads due to superimposed live loads
10 - C6.5.1 General
10 - C6.5.2 Superimposed live loads
12 - C8 COMPACTION
12 - C9 SUPPORT TYPES AND BEDDING FACTORS
12 - C9.1 Support types
12 - C9.1.1 General
13 - C9.1.3 Granular or concrete
13 - C9.1.3(a) Type 0 support
13 - C9.1.3(b)(i)(A) Type 1 support
13 - C9.1.3(b)(i)(B) Type 2 support
13 - C9.1.3(c) Type 3 support
13 - C9.1.3(d) Type 4 and Type 5 support
13 - C9.1.4 Non-granular
14 - C9.2 Bedding factors
14 - C9.2.1 Granular or concrete
14 - C9.2.3 Jacked or bored pipes
14 - C10 DESIGN CRUSHING LOAD
14 - C11 SELECTION OF CRUSHING STRENGTH CLASS
15 - APPENDIX CA - NON-GRANULAR SUPPORT TYPES
15 - CA1 SCOPE
15 - CA2 COMPACTION
15 - CA3 SUPPORT TYPES AND BEDDING FACTORS
15 - CA3.1 Support types
15 - CA3.1.1 General
15 - CA3.1.3 Type U support
15 - CA3.1.4 Type H1 and Type H2 support
16 - CA3.1.5 Type HS1 and Type HS2 support
16 - CA3.2 Bedding factors
16 - CA3.2.1 Values
16 - CA3.2.2 Reduction of values
17 - APPENDIX A - REFERENCES
18 - APPENDIX B - EXAMPLES OF THE APPLICATION OF PROVISIONS OF AS 4060
18 - B1 SCOPE
18 - B2 EXAMPLE 1
18 - B2.1 Problem
18 - B2.2 Calculation
18 - B2.2.1 Assumption
18 - B2.2.2 Working load
19 - B2.2.3 Width of trench
19 - B2.3 Solution
19 - B2.4 Comment
19 - B3 EXAMPLE 2
19 - B3.1 Problem
19 - B3.2 Calculation
20 - B3.3 Solution
19 - B3.2.1 Assumption
19 - B3.2.2 Working load
20 - B3.2.3 Bedding factor
20 - B4 EXAMPLE 3
20 - B4.1 Problem
20 - B4.2 Calculation
20 - B4.2.1 Assumption
20 - B4.2.2 Working load
21 - B4.2.3 Design crushing load
21 - B4.3 Solution
21 - B5 EXAMPLE 4
21 - B5.1 Problem
21 - B5.2 Calculation
21 - B5.2.1 Assumption
22 - B5.2.2 Working load
22 - B5.3 Solution
23 - APPENDIX C - DATA FOR DESCRIPTION, IDENTIFICATION AND CLASSIFICATION OF SOILS BY THE UNIFIED SOIL CLASSIFICATION SYSTEM
23 - C1 GENERAL

Gives background to AS4060 and helpful information for design engineers or other appropriately qualified persons and those writing specifications for the installation of vitrified clay pipelines. Emphasis is placed on the need, particularly with non-granular material, for achieving in the field support conditions consistent with the assumptions of which the equations in the Standard are based. An appendix gives worked examples which illustrate the load calculations and how the calculated values are used to select an appropriate crushing strength class of pipes and fittings for a particular pipeline.

Committee
WS/15
DocumentType
Supplement (Main)
ISBN
0 7262 7734 7
Pages
19
PublisherName
Standards Australia
Status
Withdrawn
Supersedes

First published as AS 4060 Supplement 1-1992. First published as AS 4060 Supplement 1-1992. Incorporating: Amdt 1-1993

AS 1289.F3.2-1984 Methods of testing soil for engineering purposes Soil strength and consolidation tests - Determination of the penetration resistance of a soil using the 9 kg dynamic cone penetrometer
AS 1741-1991 Vitrified clay pipes and fittings with flexible joints - Sewer quality (Reconfirmed 2018)
AS/NZS 1170.1:2002 Structural design actions Permanent, imposed and other actions
AS/NZS 3725:2007 Design for installation of buried concrete pipes
AS 1289.E3.1-1977 Methods of testing soil for engineering purposes Soil compaction and density tests - Determination of the field dry density of a soil - Sand replacement method using a sand-cone pouring apparatus
AS 2566-1982 Plastics pipelaying design

AS 4060-1992 Loads on buried vitrified clay pipes (Reconfirmed 2018)
AS/NZS 3500.3:2015 Plumbing and drainage Stormwater drainage

View more information
US$27.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.