• There are no items in your cart

AS 4084 SUPP 1-1993

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Steel storage racking - Commentary (Supplement to AS 4084-1993)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Withdrawn date

08-21-2018

Language(s)

English

Published date

01-01-1993

Preview

1 - AS 4084 Supp1:1993 STEEL STORAGE RACKING - COMMENTARY (SUPPLEMENT TO AS 4084:1993)
4 - PREFACE
4 - ACKNOWLEDGMENTS
5 - CONTENTS
6 - SECTION C1 - SCOPE AND GENERAL
6 - C1. 1 SCOPE
6 - C1. 2 REFERENCED DOCUMENTS
6 - C1. 3 DEFINITIONS
6 - C1. 4 NOTATION
6 - C1. 5 USE OF ALTERNATIVE MATERIALS OR METHODS
6 - C1. 6 GENERAL REQUIREMENTS FOR RACKING INSTALLATIONS
6 - C1. 6. 1 General
8 - C1. 6. 2 Resistance to minor impact
9 - C1. 6. 3 Bracing to buildi ng structures
10 - SECTION C2 - LOADS
10 - C2. 1 DESIGN LOADS
10 - C2. 2 VERTICAL IMPACT LOADS
10 - C2. 3 HORIZONTAL LOADS
10 - C2. 3. 1 General
10 - C2. 3. 2 Loadi ng and off- loading (placement loads)
11 - C2. 3. 3 Initial out-of-plumb
14 - SECTION C3 - DESIGN PROCEDURES
14 - C3. 1 GENERAL
14 - C3. 2 METHODS OF STRUCTURAL ANALYSIS
14 - C3. 2. 1 Upright- frame design
14 - C3. 2. 1(b) Non- linear (second order) elastic
14 - C3. 2. 2 Beams
17 - SECTION C4 - DESIGN OF COLD-FORMED STEEL ELEMENTS AND MEMBERS
17 - INTRODUCTION
17 - C4.1 ELEMENTS
17 - C4.2 MEMBERS
17 - C4.2.2 Flexural members
18 - C4.2.3 Axially-loaded compression members
19 - C4.2.3.2 Sections not subject to torsional-flexural buckling
19 - C4.2.3.3 Doubly symmetric or monosymmetric sections subject to torsional-flexural buckling
20 - C4.2.3.4 Monosymmetric sections subject to distortional buckling
22 - SECTION C5 - UPRIGHT FRAME STABILITY
22 - C5.1 EFFECTIVE LENGTH FACTORS
22 - C5.1.2 Flexural buckling in the direction perpendicular to the upright frames
22 - C5.1.2.1 Racking not braced against side-sway
24 - C5.1.2.2 Racking braced against side-sway
25 - C5.1.3 Flexural buckling in the plane of the upright frames
27 - C5.1.4 Torsional buckling
28 - C5.2 STABILITY OF TRUSSED-BRACED UPRIGHT FRAMES
29 - SECTION C6 - CONNECTIONS AND BEARING PLATES
29 - C6.2 BEAM SUPPORT CONNECTIONS
29 - C6.3 BASE PLATES
29 - C6.4 CONNECTIONS TO BUILDINGS
29 - C6.5 UPRIGHT SPLICES
30 - SECTION C7 - TOLERANCES AND CLEARANCES
30 - C7.1 FINISHED TOLERANCES IN UNLOADED CONDITION
30 - C7.2 UNIT LOAD CLEARANCES
31 - SECTION C8 - TEST METHODS
31 - C8.1 INTRODUCTION
31 - C8.1.1 General
31 - C8.2 STUB COLUMN TESTS
31 - C8.2.2 Evaluation of test results
32 - C8.3 PALLET BEAM TESTS
32 - C8.3.1 Simply-supported pallet beam tests
32 - C8.3.1.2 Test set-up
33 - C8.3.1.4 Evaluation of test results
33 - C8.3.2 Pallet beam in upright frames assembly tests
33 - C8.3.2.2 Test set-up
33 - C8.3.2.4 Evaluation of test results
34 - C8.4 PALLET BEAM TO COLUMN CONNECTION TESTS
35 - C8.4.1 Cantilever test
35 - C8.4.1.2 Test set-up
35 - C8.4.1.4 Evaluation of test results
36 - C8.4.2 Portal test
36 - C8.4.2.2 Test set-up
37 - C8.4.2.4 Evaluation of test results
37 - C8.5 UPRIGHT FRAME TEST
37 - C8.5.2 Horizontal load in the direction perpendicular to the upright frame
39 - SECTION C9 - OPERATION AND MAINTENANCE OF ADJUSTABLE PALLET RACKING
39 - C9.1 GENERAL
39 - C9.1.1 Safe working loads
39 - C9.1.2 Alteration of the racking installation
39 - C9.1.3 Operating instructions
39 - C9.1.4 Hazardous situations
39 - C9.1.5 Damage report
39 - C9.2 INSPECTIONS
41 - C9.3 DAMAGE DUE TO IMPACT
41 - C9.4 OUT-OF-PLUMB OF RACKING
42 - REFERENCES

Provides background and explanatory material to the requirements of the Standard. It also provides advice and guidance in certain areas which cannot at this stage be covered by the Standard.

The Standard specifically limits its application to the design of adjustable static pallet racking (in permissible stress method) made of cold-formed or hot-rolled members. The Standard does not cover materials other than steel.It is the intention of the Standard to cover such racking commonly referred to as 'adjustable pallet racking' and 'stacker' racking (both 'open' and 'closed' faced) and 'shelf' and other racking, all of which are static.Other commonly known racking such as 'drive-in' and 'drive-through' racking, cantilever and mobile racking are excluded from the Standard. Due to their nature and special requirements for stability and effective length criteria, these types of racking are not addressed by the Standard.

Committee
BD-062
DocumentType
Supplement (Main)
ISBN
0 7262 7890 4
Pages
37
PublisherName
Standards Australia
Status
Withdrawn

First published as AS 4084 Supplement 1-1993.

AS 1538-1988 Cold-formed Steel Structures Code
AS 1250-1981 The use of steel in structures (known as the SAA Steel Structures Code)

View more information