• There are no items in your cart

AS 60204.11-2006

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Safety of machinery - Electrical equipment of machines Requirements for HV equipment for voltages above 1000 V a.c. or 1500 V d.c and not exceeding 36 kV (IEC 60204-11, Ed. 1.0 (2000) MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

02-07-2024

Language(s)

English

Published date

12-08-2006

Preview

1 - AS 60204.11-2006 Safety of machinery„Electrical equipment of machines Part 11: Requirements for HV equipment for voltages abo
4 - PREFACE
5 - CONTENTS
7 - INTRODUCTION
9 - 1 Scope
10 - 2 Normative references
12 - 3 Definitions
18 - 4 General requirements
18 - 4.1 General considerations
19 - 4.2 Selection of electrical equipment
19 - 4.3 Electrical supply
19 - 4.4 Physical environment and operating conditions
20 - 4.5 Transportation and storage
20 - 4.6 Provisions for handling
20 - 4.7 Installation
20 - 5 Incoming supply conductor terminations, devices for disconnecting and switching off, and means for earthing
20 - 5.1 Incoming supply conductor terminations
20 - 5.2 Supply disconnecting (isolating) devices and means for earthing
22 - 5.3 Devices for switching off for prevention of unexpected start-up
23 - 5.4 Devices for disconnecting and means for earthing HV equipment
23 - 5.5 Protection against unauthorized, inadvertent and/or mistaken operation
23 - 6 Protection against electric shock
23 - 6.1 General
24 - 6.2 Protection against direct contact
24 - 6.3 Protection against indirect contact
26 - 7 Protection of HV equipment
26 - 7.1 General
26 - 7.2 Overcurrent protectio
27 - 7.3 Earth fault protection
28 - 7.4 Protection against overvoltages due to lightning and to switching surges
28 - 7.5 Protection against other abnormal conditions
28 - 8 Equipotential bonding
28 - 8.1 General
29 - 8.2 Protective bonding circuit
32 - 9 Control circuits and control functions
32 - 10 Operator interface and machine-mounted control devices
32 - 11 Electronic equipment
32 - 12 Controlgear: location, mounting, and enclosures
32 - 12.1 General requirements
33 - 12.2 Location and mounting
33 - 12.3 Degrees of protection
34 - 12.4 Enclosures, doors and openings
35 - 12.5 Access to HV equipment
35 - 13 Conductors and cables
35 - 13.1 General requirements
35 - 13.2 Conductors
36 - 13.3 Insulation and sheath materials
36 - 13.4 Current-carrying capacity in normal service
36 - 13.5 Conductor and cable voltage drop
36 - 13.6 Minimum cross-sectional area
36 - 13.7 Flexible cables
38 - 13.8 Conductor wires, conductor bars and slip-ring assemblies
39 - 14 Wiring practices
39 - 14.1 Connections and routing
40 - 14.2 Identification of conductors
40 - 14.3 Flexible cables
41 - 14.4 Plug/socket combinations
41 - 14.5 Dismantling for shipment
41 - 14.6 Cable trays
41 - 14.7 Wiring in hazardous areas
42 - 15 Electric motors and associated equipment
42 - 15.1 General
42 - 15.2 Motor connection boxes
42 - 16 Accessories
42 - 16.1 Accessories for earthing and short-circuiting live parts
42 - 16.2 Voltage detectors
42 - 16.3 Accessories for safe working
42 - 17 Marking, warning signs and reference designations
42 - 17.1 General
42 - 17.2 Warning signs
43 - 18 Technical documentation
43 - 19 Testing and verification
43 - 19.1 General
43 - 19.2 Earthing system tests
44 - 19.3 Insulation resistance tests
44 - 19.4 Voltage tests
44 - 19.5 Functional tests
44 - 19.6 IP tests for HV equipment outside electrical operating areas
44 - 19.7 Retesting
45 - Annex A (informative) Examples of machines covered by this part of IEC 60204
46 - Annex B (informative) Inquiry form for the HV equipment of machines
49 - Annex C (informative) Method of calculation for the cross-sectional area of bare protective conductors in supply systems with direct earthing or low impedance earthing of the neutral
50 - Annex D (informative) Relationship between cable rated voltages and highest voltage for HV equipment
51 - Annex E (informative) Rationalization of the use of terms relating to earthing and protective bonding
54 - Index

AS 60204.11-2006 modifies and adopts IEC 60204-11, Ed. 1.0 (2000) which applies to the electrical and electronic equipment and systems of machines, including a group of machines working together in a coordinated manner, but excluding higher level system aspects (i.e. communications between systems).

Committee
EL-017
DocumentType
Standard
ISBN
0 7337 7900 X
Pages
47
ProductNote
Pending Revision indicates that as a result of the Aged Standards review process, the document needs updating. If no project proposal, meeting the quality criteria, is received within the 12 month timeframe, the document shall be withdrawn.
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

First published as AS 60204.11-2006.

AS/NZS 61241.10:2005 Electrical apparatus for use in the presence of combustible dust Classification of areas where combustible dusts are or may be present
AS/NZS 60079.27(INT):2006 Electrical apparatus for explosive gas atmospheres Fieldbus intrinsically safe concept (FISCO) and fieldbus non-incendive concept (FNICO)
AS/NZS 60079.18:2005 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection encapsulation m electrical apparatus
AS/NZS 2381.2:2006 Electrical equipment for explosive atmospheres - Selection, installation and maintenance Flameproof enclosure d
AS 61508.2-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Requirements for electrical/electronic/programmable electronic safety-related systems
AS/NZS 60079.2:2002 Electrical apparatus for explosive gas atmospheres Pressurized enclosures 'p'
AS 2380.4-1994 Electrical equipment for explosive atmospheres - Explosion-protection techniques Pressurized rooms or pressurized enclosures (Reconfirmed 2013)
AS/NZS 60079.25:2004 Electrical apparatus for explosive gas atmospheres Intrinsically safe systems
AS/NZS 61241.11:2006 Electrical apparatus for use in the presence of combustible dust Protection by intrinsic safety iD
AS 4024.2-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Optoelectronic devices
AS/NZS 61241.4:2002 Electrical apparatus for use in the presence of combustible dust Type of protection 'pD'
AS/NZS 60079.11:2000 Electrical apparatus for explosive gas atmospheres Intrinsic safety 'i'
AS 61508.4-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Definition and abbreviations
AS 60417.1-2004 Graphical symbols for use on equipment - Overview and application
AS/NZS 61241.0:2005 Electrical apparatus for use in the presence of combustible dust General requirements
AS 61508.6-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Guidelines on the application of AS 61508.2 and AS 61508.3
AS/NZS 60079.7:2002 Electrical apparatus for explosive gas atmospheres Increased safety 'e'
AS/NZS 60079.1:2005 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd'
AS/NZS 60079.6:2000 Electrical apparatus for explosive gas atmospheres Oil-immersion 'o'
AS/NZS 60079.5:2000 Electrical apparatus for explosive gas atmospheres Powder filling 'q'
AS/NZS 60079.20:2000 Electrical apparatus for explosive gas atmospheres Data for flammable gases and vapours, relating to the use of electrical apparatus
AS 1359.101-1997 Rotating electrical machines - General requirements - Rating and performance
AS/NZS 2381.1:2005 Electrical equipment for explosive gas atmospheres - Selection, installation and maintenance - General requirements
AS 61508.7-2001 Functional safety of electrical/electronic/programmable electronic safety-related systems - Overview of techniques and measures
AS/NZS 61241.14:2005 Electrical apparatus for use in the presence of combustible dust Selection and installation (IEC 61241-14, Ed.1.0(2004) MOD)
AS 60417.2.5-2004 Graphical symbols for use on equipment Home electric appliances
AS/NZS 60079.4:2000 Electrical apparatus for explosive gas atmospheres Method of test for ignition temperature
AS 1852.441-1985 International electrotechnical vocabulary - Switchgear, controlgear and fuses
AS/NZS 61241.2.3:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the minimum ignition energy of dust/air mixtures
AS/NZS 61241.2.1:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Methods for determining the minimum ignition temperature of dust
AS 2264-1995 A.C. insulation-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 38 kV
AS 60417.2.7-2004 Graphical symbols for use on equipment Safety aspects
AS 60417.2.3-2004 Graphical symbols for use on equipment Telephone and telecommunications
AS 60417.2.1-2004 Graphical symbols for use on equipment General application
AS/NZS 61241.18:2005 Electrical apparatus for use in the presence of combustible dust Protection by encapsulation 'mD'
AS 60204.1-2005 Safety of machinery - Electrical equipment of machines General requirements (IEC 60204-1, Ed. 5 (FDIS) MOD)
AS 2380.9-1991 Electrical equipment for explosive atmospheres - Explosion-protection techniques Type of protection n - Non-sparking
AS 1852.826-1983 International electrotechnical vocabulary - Electrical installations of buildings
AS 62271.200-2005 High-voltage switchgear and controlgear A.C. metal-enclosed switchgear and controlgear for rated voltages above 1 kV and up to and including 52 kV (IEC 62271-200, Ed. 1 (2003) MOD)
AS 60417.2.2-2004 Graphical symbols for use on equipment Audiovisual equipment
AS/NZS 60079.0:2005 Electrical apparatus for explosive gas atmospheres General requirements
AS 4024.4-1998 Safeguarding of machinery Installation and commissioning requirements for electro-sensitive systems - Pressure-sensitive devices (Reconfirmed 2016)
AS 2380.1-1989 Electrical equipment for explosive atmospheres - Explosion-protection techniques General requirements (Reconfirmed 2013)
AS 1824.1-1995 Insulation co-ordination Definitions, principles and rules
AS/NZS 60079.1.1:2002 Electrical apparatus for explosive gas atmospheres Flameproof enclosures 'd' - Method of test for ascertainment of maximum experimental safe gap
AS 61508.1-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - General requirements
AS/NZS 60079.26 (INT):2005 Electrical apparatus for explosive gas atmospheres Construction, test and marking of Group II Zone 0 electrical apparatus
AS/NZS 60079.12:2000 Electrical apparatus for explosive gas atmospheres Classification of mixtures of gases or vapours with air according to their maximum experimental safe gaps and minimum igniting currents
AS 61508.3-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Software requirements
AS 4024.3-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Optoelectronic devices
AS/NZS 60079.10:2004 Electrical apparatus for explosive gas atmospheres Classification of hazardous areas (IEC 60079-10:2002 MOD)
AS 61508.5-1999 Functional safety of electrical/electronic/programmable electronic safety-related systems - Examples of methods for the determination of safety integrity levels
AS 4024.5-1998 Safeguarding of machinery Manufacturing and testing requirements for electro-sensitive systems - Pressure-sensitive devices
AS/NZS 61241.1:2005 Electrical apparatus for use in the presence of combustible dust Protection by enclosures 'tD'
AS/NZS 4024.1:2006 Series Safety of machinery Safety of machinery series
AS/NZS 60079.15:2006 Electrical apparatus for explosive gas atmospheres Construction, test and marking of type of protection, n electrical apparatus
AS 60417.2.6-2004 Graphical symbols for use on equipment Medical equipment
AS 60417.2.4-2004 Graphical symbols for use on equipment Maritime navigation
AS 60529-2004 Degrees of protection provided by enclosures (IP Code) (Reconfirmed 2018)
AS/NZS 61241.2.2:2000 Electrical apparatus for use in the presence of combustible dust Test methods - Method for determining the electrical resistivity of dust in layers

AS/NZS 4871.1:2010 Electrical equipment for mines and quarries General requirements
AS 4722-2009 Passenger ropeways and passenger conveyors
AS 4024.3002-2009 Safety of machinery Materials forming and shearing - Hydraulic power presses
AS IEC 61800.5.2-2013 Adjustable speed electrical power drive systems Safety requirements - Functional
AS 4024.3101-2008 Safety of machinery Materials cutting - Milling machines (including boring machines) - Safety requirements (Reconfirmed 2018)
AS/NZS 1418.10:2011 Cranes, hoists and winches Mobile elevating work platforms
AS/NZS 4240.1:2009 Remote control systems for mining equipment Design, construction, testing, installation and commissioning (Reconfirmed 2021)
AS 3533.1-2009 Amusement rides and devices Design and construction
AS IEC 61800.5.1-2013 Adjustable speed electrical power drive systems Safety requirements - Electrical, thermal and energy
AS ISO 21789:2014 Gas turbine applications - Safety
AS 60034.1-2009 Rotating electrical machines Rating and performance
AS/NZS 4871.1:2012 Electrical equipment for mines and quarries General requirements
AS/NZS 3007:2013 Electrical equipment in mines and quarries - Surface installations and associated processing plant
AS 4233.2:2013 High pressure water jetting systems Construction and performance

View more information
US$118.31
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.