• There are no items in your cart

AS/NZS 1158.6:2004

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Lighting for roads and public spaces Luminaires
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

03-08-2023

Language(s)

English

Published date

09-23-2004

Preview

1 - AS/NZS 1158.6:2004 LIGHTING FOR ROADS AND PUBLIC SPACES - LUMINAIRES
4 - PREFACE
6 - CONTENTS
8 - SECTION 1 SCOPE AND GENERAL
8 - 1.1 SCOPE
8 - 1.2 APPLICATION
8 - 1.3 REFERENCED DOCUMENTS
9 - 1.4 DEFINITIONS
9 - 1.5 ENVIRONMENTAL CONDITIONS
9 - 1.6 MARKING
9 - 1.6.1 General
9 - 1.6.2 Information on interior of luminaire
10 - 1.6.3 Coded information on exterior of luminaire
10 - 1.6.4 Additional internal marking for luminaires with high pressure sodium lamps
10 - 1.6.5 Additional marking for luminaires with metal halide lamps
11 - 1.7 ADDITIONAL INFORMATION
12 - SECTION 2 MECHANICAL AND PHYSICAL REQUIREMENTS
12 - 2.1 SCOPE OF SECTION
12 - 2.2 GENERAL DESIGN AND ARRANGEMENT
12 - 2.2.1 Form and construction
12 - 2.2.2 Required ingress protection
12 - 2.3 CONSTRUCTION
12 - 2.3.1 Resistance to vandalism
13 - 2.3.2 Other aspects
13 - 2.4 LUMINAIRE BODY
13 - 2.4.1 Material
13 - 2.4.2 Component fixing devices
14 - 2.4.3 Seals and gaskets
14 - 2.5 VISORS
14 - 2.5.1 Attachment to luminaire body
14 - 2.5.2 Materials and construction
15 - 2.6 OPTICAL SYSTEM
15 - 2.7 FIXING SPIGOT ENTRY
15 - 2.7.1 Luminaires other than top-entry type
16 - 2.7.2 Top-entry luminaires
17 - 2.8 MAXIMUM MASS OF LUMINAIRES
17 - 2.8.1 Standard side entry luminaires
17 - 2.8.2 Non-standard side entry luminaires
17 - 2.8.3 Post-top luminaires
17 - 2.8.4 Top-entry luminaires
20 - SECTION 3 ELECTRICAL WIRING AND COMPONENTS
20 - 3.1 SCOPE OF SECTION
20 - 3.2 BALLASTS
20 - 3.3 IGNITERS
21 - 3.4 REQUIREMENTS FOR HID LAMPS
21 - 3.4.1 Lampholder requirements
21 - 3.4.2 Required lamp types
22 - 3.5 REQUIREMENTS FOR FLUORESCENT LUMINAIRES
22 - 3.6 ELECTRICAL SUPPLY
22 - 3.7 CABLE ENTRY
22 - 3.8 TERMINAL BLOCK
23 - 3.9 ARRANGEMENT OF CONTROL GEAR
23 - 3.9.1 Mounting of equipment
23 - 3.9.2 Hinged trays
23 - 3.10 SOCKET FOR PHOTOELECTRIC CELL SWITCH
23 - 3.10.1 Base type
23 - 3.10.2 Connection arrangement for luminaires with a D2 base
24 - 3.10.3 Colour coding of connecting wiring
24 - 3.10.4 Failure mode
25 - 3.11 INTERNAL WIRING
25 - 3.12 SPECIFIC ELECTRICAL SAFETY REQUIREMENTS
25 - 3.13 PROTECTION AGAINST ELECTRIC SHOCK
25 - 3.13.1 General
25 - 3.13.2 Testing of photoelectric controlled luminaires
26 - SECTION 4 ADDITIONAL REQUIREMENTS FOR PARTICULAR LUMINAIRES
26 - 4.1 OPTIONAL COMPONENTS (CATEGORY V AND CATEGORY P LUMINAIRES)
26 - 4.1.1 Power factor correction capacitors
27 - 4.1.2 Blocking inductor
27 - 4.1.3 Overcurrent protection
27 - 4.1.4 Interference suppression capacitors
28 - SECTION 5 PERFORMANCE AND TESTING
28 - 5.1 SCOPE OF SECTION
28 - 5.2 TESTING OF PE CELL TYPE LUMINAIRES
28 - 5.3 BALLAST LOSSES
29 - 5.4 LAMP OPERATION
29 - 5.5 WIND FORCE TEST
29 - 5.5.1 Test conditions and procedure
29 - 5.5.2 Performance assessment
30 - 5.6 VIBRATION TESTING
30 - 5.6.1 Application
31 - 5.6.2 Test procedure
32 - 5.6.3 Application as type test
32 - 5.7 INGRESS PROTECTION TEST
32 - 5.8 RESISTANCE TO EXTERNAL MECHANICAL IMPACT
32 - 5.9 IMPULSE VOLTAGE TEST
32 - 5.9.1 Test conditions and procedure
32 - 5.9.2 Test criteria
33 - 5.10 THERMAL ENDURANCE AND THERMAL TESTING REQUIREMENTS
33 - 5.11 ADDITIONAL TESTS
34 - SECTION 6 SUPPORTING DOCUMENTATION
34 - 6.1 SCOPE OF SECTION
34 - 6.2 GENERAL INFORMATION
34 - 6.3 PHOTOMETRIC INFORMATION
34 - 6.4 STATEMENTS OF COMPLIANCE
35 - APPENDIX A - GUIDE TO ALTERNATIVE MATERIALS AND TECHNOLOGIES
35 - A1 INTRODUCTION
35 - A2 BODY MATERIAL
35 - A3 PLASTICS IN NON-LOAD BEARING APPLICATIONS
36 - A4 VISORS
37 - A5 CONTROL GEAR
37 - A5.1 General
37 - A5.2 Electronic control gear
37 - A5.3 Control gear location
38 - A6 LAMPS
39 - A6.1 High xenon or super high pressure sodium lamps
39 - A6.2 Lampholders
40 - APPENDIX B - LIST OF REFERENCED DOCUMENTS
42 - APPENDIX C - INFORMATION RECOMMENDED TO BE SUPPLIED WITH ENQUIRY OR ORDER
43 - APPENDIX D - POLE/BRACKET ARM END DETAIL FOR TOP-ENTRY LUMINAIRES

Sets out requirements for the design, construction, performance and testing of luminaires intended for use in Category V and Category P lighting schemes as per AS/NZS 1158.1.1 and AS/NZS 1158.3.1 respectively.

This Standard applies to all luminaires, with or without integral control gear, which are intended for use in Category V lighting schemes in accordance with AS/NZS 1158.1.1 and in Category P schemes in accordance with AS/NZS 1158.3.1.The requirements set out are, in general, based on engineering practices, construction materials and components that have, by long time experience in in-field application, been shown to realise the target service life of the luminaire. However instances can arise where departure from the aforesaid requirements may be justified, particularly in the case of those relating to materials. Where this is so it is referred to in the relevant text of the Standard, e.g. Clauses 2.4.1 and 2.5.2.1. However it must be noted that such departures can reduce the target life and this reduction can be significant. The range of lamp types and wattages utilized in the luminaires has not been specified because of the great range involved and because the lamp itself is not a determinant of the target service life of the luminaire. There is long-term experience of the reliability of many of the lamps and, importantly in the context of this Standard, of the associated control gear but limited experience in the application of some lamp/control gear combinations in Category V and P lighting schemes, e.g. fluorescent lamps and electronic ballasts. NOTE: Guidance on some alternative materials for lamps and control gear is given in Appendix A.

Committee
LG-002
DocumentType
Standard
ISBN
0 7337 6269 7
Pages
36
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

First published in Australia as AS 3771-1990.Second edition 1998.First published in New Zealand as NZS 6705.2.3:1986.AS 3771-1998 and NZS 6705.2.3:1986 jointly revised, amalgamated and redesignated as AS/NZS 1158.6:2004. First published in Australia as AS 3771-1990. Second edition 1998. First published in New Zealand as NZS 6705.2.3:1986. AS 3771-1998 and NZS 6705.2.3:1986 jointly revised, amalgamated and redesignated as AS/NZS 1158.6:2004.

AS 60038-2000 Standard voltages
AS/NZS 60923:1998 Auxiliaries for lamps - Ballasts for discharge lamps (excluding tubular fluorescent lamps) - Performance requirements (Reconfirmed 2013)
AS 2768-1985 Electrical insulating materials - Evaluation and classification based on thermal endurance
AS 1874-2000 Aluminium and aluminium alloys - Ingots and castings (Reconfirmed 2018)
AS/NZS 61049:2002 Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - Performance requirements (Reconfirmed 2016)
AS 60068.2.6-2003 Environmental testing Tests - Test Fc: Vibration (sinusoidal) (Reconfirmed 2018)
AS/NZS 61347.1:2002 Lamp controlgear General and safety requirements (IEC 61347-1:2000, MOD)
AS/NZS 2208:1996 Safety glazing materials in buildings
AS/NZS 60598.1:2003 Luminaires General requirements and tests (IEC 60598-1:2003, MOD)
AS/NZS 61048:2002 Auxiliaries for lamps - Capacitors for use in tubular fluorescent and other discharge lamp circuits - General and safety requirements (IEC 61048:1991, MOD)
AS/NZS 61347.2.1:2002 Lamp controlgear Particular requirements for starting devices (other than glow starters)
AS/NZS CISPR 15:2002 Limits and methods of measurement of radio disturbance characteristics of electrical lighting and similar equipment (CISPR 15:2000, MOD)
AS/NZS 61231:2001 International lamp coding system (ILCOS) (Reconfirmed 2013)
AS/NZS 1158.0:1997 Road lighting Introduction
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements
AS 1798-1992 Lighting poles and bracket arms - Preferred dimensions
AS/NZS 1158.1.1:1997 Road Lighting Vehicular traffic (Category V) lighting - Performance and installation design requirements
AS/NZS 61347.2.9:2004 Lamp controlgear Particular requirements for ballasts for discharge lamps (excluding fluorescent lamps) (IEC 61347-2-9:2000 MOD)
AS/NZS 1158.3.1:1999 Road lighting Pedestrian area (Category P) lighting - Performance and installation design requirements
AS/NZS 3191:2003 Electric flexible cords
AS 3140-1994 Approval and test specification - Edison-type screw lampholders

AS 3961-2005 The storage and handling of liquefied natural gas
AS/NZS 1158.4:2009 Lighting for roads and public spaces Lighting of pedestrian crossings
AS/NZS 1158.3.1:2005 Lighting for roads and public spaces Pedestrian area (Category P) lighting - Performance and design requirements
AS/NZS 1158.1.1:2005 Lighting for roads and public spaces Vehicular traffic (Category V) lighting - Performance and design requirements
AS/NZS 1158.5:2007 Lighting for roads and public spaces Tunnels and underpasses
AS/NZS 1158.0:2005 Lighting for roads and public spaces Introduction

View more information
US$82.57
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.