AS/NZS 2373.2:1995

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Electric cables for control and protection circuits - Twisted pair control cables
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Language(s)

English

Published date

01-01-1995

Preview

1 - AS/NZS 2373.2:1995 ELECTRIC CABLES FOR CONTROL AND PROTECTION CIRCUITS - TWISTED PAIR CONTROL CABLES
4 - PREFACE
5 - CONTENTS
6 - 1 SCOPE
6 - 2 REFERENCED DOCUMENTS
6 - 3 DEFINITIONS
6 - 3.1 Control cable
6 - 3.2 Lay-up
6 - 3.3 Routine tests
6 - 3.4 Special tests
6 - 3.5 Type tests
7 - 3.6 Voltage designation
7 - 3.7 Wavelength or length of lay
7 - 4 VOLTAGE DESIGNATION
7 - 5 CONDUCTORS
7 - 6 INSULATION
7 - 6.1 Material
7 - 6.2 Application
7 - 6.3 Thickness
7 - 6.4 Criteria
7 - 6.5 Identification of twisted pairs
7 - 7 NUMBER OF CORES AND CONFIGURATION
7 - 8 LAY-UP OF TWISTED PAIRS
7 - 8.1 Length of lay of twisted pairs
7 - 8.2 Lay-up of the twisted pairs
8 - 9 FILLERS AND BINDERS
8 - 10 BINDER TAPE
8 - 11 COLLECTIVE INSULATION
8 - 11.1 Application
8 - 11.2 Thickness
9 - 12 METALLIC SCREENS
9 - 12.1 Application
9 - 12.2 Material
9 - 12.3 Continuity conductor
9 - 13 MOISTURE BARRIER
9 - 14 BEDDING
9 - 15 METALLIC SHEATH
9 - 16 SEPARATION SHEATH
9 - 17 ARMOUR
9 - 18 NON-METALLIC SHEATH
9 - 18.1 Material
9 - 18.2 Construction
10 - 18.3 Thickness
10 - 18.4 Web dimensions
10 - 19 INSECT-RESISTANT BARRIER
10 - 20 CATENARY SUPPORT WIRES
10 - 20.1 Material
10 - 20.2 Dimensions
10 - 21 MARKING
10 - 21.1 Information to be marked
10 - 21.2 Means of marking
11 - 21.3 Metre marking
11 - 21.4 Marking of drums, coils or reels
11 - 22 CONSTRUCTION AND DIMENSIONS
15 - 23 TESTING
15 - 24 GUIDE TO BENDING RADIUS
16 - APPENDIX A - THE FICTITIOUS CALCULATION METHOD FOR THE DETERMINATION OF THE DIMENSIONS OF PROTECTIVE COVERINGS
16 - A1 INTRODUCTION
16 - A2 GENERAL
16 - A3 METHOD
16 - A3.1 Conductors
16 - A3.2 Cores
17 - A3.3 Diameter over laid-up pairs
17 - A3.4 Collective insulation
17 - A3.5 Bedding
17 - A3.6 Metallic screen
18 - A3.7 Moisture barrier
18 - A3.8 Separation sheath
18 - A3.9 Metal sheath
18 - A3.10 Armour
19 - A3.11 Non-metallic sheath
19 - A3.12 Polyamide jacket
20 - APPENDIX B - PURCHASING GUIDELINES
20 - B1 GENERAL
20 - B2 INFORMATION TO BE SUPPLIED BY THE PURCHASER
21 - APPENDIX C - HIGH VOLTAGE TESTS
21 - C1 HIGH VOLTAGE TEST FOR TWISTED-PAIR CABLES
21 - C1.1 Test voltage
21 - C1.2 Test method
22 - APPENDIX D - GUIDE TO BENDING RADIUS OF NON-AERIAL TWISTED PAIR CONTROL CABLES
22 - D1 METHOD
22 - D2 MINIMUM BENDING RADIUS
23 - APPENDIX E - ROUNDING OF NUMBERS
23 - E1 ROUNDING OF NUMBERS FOR THE PURPOSE OF THE ‘FICTITIOUS CALCULATION METHOD
23 - E2 ROUNDING OF NUMBERS FOR OTHER PURPOSES

Specifies the requirements for screened polyethylene (PE) insulated twisted pair control cables for voltages up to 0.6/1 kV, including a catenary support wire for aerial cables, intended for use in control, supervisory, protection and instrumentation circuits. It does not apply to cables used solely for telecommunication purposes.

This Standard specifies requirements for screened polyethylene(PE) insulated twisted pair control cables for voltages up to and including 0.6/1 kV. A catenary support wire is included for aerial cables.It applies to cables intended for use in control, supervisory, protection and instrumentation circuits. Control cables complying with this Standard may be used between power stations, substations or in industrial applications.It does not apply to cables used solely for telecommunication.

Committee
EL-003
DocumentType
Standard
ISBN
0 7262 9683 X
Pages
18
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Under Revision see DR 02567 First published as AS 2373.2-1982.Jointly revised and designated as Joint Standard AS/NZS 2373.2:1995. First published as AS 2373.2-1982. Jointly revised and designated as Joint Standard AS/NZS 2373.2:1995.

AS 1222.1-1992 Steel conductors and stays - Bare overhead Galvanized (SC/GZ) (Reconfirmed 2016)
AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
AS 1125-1993 Conductors in insulated electric cables and flexible cords
AS 1931.1-1996 High-voltage test techniques - General definitions and test requirements

AS/NZS 3808:1998 Insulating and sheathing materials for electric cables
AS/NZS 3808:2000 Insulating and sheathing materials for electric cables

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.