• There are no items in your cart

AS/NZS 2891.14.1.2:1999

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Methods of sampling and testing asphalt Field density tests - Determination of field density of compacted asphalt using a nuclear surface moisture-density gauge - Backscatter mode
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

01-31-2024

Language(s)

English

Published date

04-05-1999

1 - AS/NZS 2891.14.1.2:1999 METHODS OF SAMPLING AND TESTING ASPHALT - FIELD DENSITY TESTS-DETERMINATION OF FIELD DENSITY OF ....
1 - 1 SCOPE
1 - 2 REFERENCED DOCUMENTS
1 - 3 SAFETY PRECAUTIONS
2 - 4 APPARATUS
2 - 5 GAUGE CALIBRATION AND OPERATIONAL CHECKS
2 - 6 PROCEDURE
3 - 7 CALCULATION
3 - 8 TEST REPORT
3 - 8.1 Test results
3 - 8.2 General information
5 - APPENDIX A - OPERATIONAL CHECKS
5 - A1 STANDARD COUNT CHECKS
5 - A2 GAUGE FUNCTION CHECKS
6 - A3 DENSITY SYSTEM CONSISTENCY CHECK
7 - APPENDIX B - DENSITY ADJUSTMENTS
7 - B1 GENERAL
7 - B2 DETERMINATION OF DENSITY OFFSET DATA
7 - B3 CALCULATION
8 - B4 TEST REPORT
8 - B5 CHECKING AND REDETERMINATION OF DENSITY OFFSET VALUES

This Standard sets out the method for determining the field density of layers of asphalt using a nuclear surface moisture-density gauge in the backscatter mode of operation.

This Standard sets out the method for determining the field density of layers of asphalt using a nuclear surface moisture-density gauge in the backscatter mode of operation. The method is applicable to asphalt layers between 50 mm and 100 mm thick and to asphalts having a nominal maximum size not greater than 40 mm.The method does not detail the operation of the gauge but refers the operator to the manufacturers handbook.When nuclear gauges are used for density measurement, the quantity of material being assessed is not precisely known. However, reference to the manufacturer's handbook and to current literature may indicate the likely volume.A nuclear gauge gives an indirect measure of field density and, hence, the backscatter mode requires calibration, in accordance with AS/NZS 2891.14.4. Regular checks on the operation and the calibration of the gauge are also required (see Appendix A). When used in the backscatter mode, a density offset is determined for each combination of asphalt mix/layer thickness to be tested (see Appendix B).

Committee
CE-006
DocumentType
Standard
ISBN
0 7337 2578 3
Pages
9
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

First published as AS/NZS 2891.14.1.2:1999.

AS/NZS 2891.14.4:1999 Methods of sampling and testing asphalt Field density tests - Calibration of nuclear surface moisture-density gauge - Backscatter mode
AS 2891.1-1986 Methods of sampling and testing asphalt Sampling of asphalt
AS 2891.9.1-1993 Methods of sampling and testing asphalt Determination of bulk density of compacted asphalt - Waxing procedure
AS 2891.9.2-1993 Methods of sampling and testing asphalt Determination of bulk density of compacted asphalt - Presaturation method
AS 2891.9.3-1993 Methods of sampling and testing asphalt Determination of bulk density of compacted asphalt - Mensuration method

AS 2150-2005 Hot mix asphalt - A guide to good practice
AS/NZS 2891.14.5:1999 Methods of sampling and testing asphalt Field density tests - Density ratio of compacted asphalt
AS/NZS 2891.14.4:1999 Methods of sampling and testing asphalt Field density tests - Calibration of nuclear surface moisture-density gauge - Backscatter mode

View more information
US$48.59
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.