• There are no items in your cart

AS/NZS 3200.2.31:1996

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Medical electrical equipment - Particular requirements for safety - External cardiac pacemakers with internal power source
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Published date

01-01-1996

Preview

1 - AS/NZS 3200.2.31:1996 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY-EXTERNAL CARDIAC PACEMAKERS WITH .....
4 - PREFACE
6 - CONTENTS
9 - SECTION ONE: GENERAL
9 - 1 Scope and object
9 - 1.1* Scope
9 - 1.2 Object
9 - 1.3 Particular Standards
10 - 2* Terminology and definitions
11 - 5 Classification
11 - 6 Identification, marking and documents
11 - 6.1 Marking on the outside of the EQUIPMENT or EQUIPMENT parts
12 - 6.3 Marking of Controls and instruments
12 - 6.8 Accompanying documents
12 - 6.8.2 Instructions for use
14 - 7* Power input
14 - SECTION TWO: ENVIRONMENTAL CONDITIONS
15 - SECTION THREE: PROTECTION AGAINST ELECTRICAL SHOCK HAZARDS
15 - 14 Requirements related to classification
15 - 14.1* CLASS I EQUIPMENT
15 - 14.2* CLASS II EQUIPMENT
15 - 14.4* CLASS I and CLASS II EQUIPMENT
15 - 14.5* INTERNALLY POWERED EQUIPMENT
15 - 19 Continuous LEAKAGE CURRENTS and PATIENT AUXILIARY CURRENTS
15 - 19.1 General requirements
15 - 19.3 Allowable values
16 - 19.4 Tests
16 - SECTION FOUR: PROTECTION AGAINST MECHANICAL HAZARDS
16 - SECTION FIVE: PROTECTION AGAINST HAZARDS FROM HAZARDS FROM
16 - 36* Electromagnetic compatibility
16 - 36.202.1* ELECTROSTATIC DISCHARGE
17 - SECTION SIX: PROTECTION AGAINST HAZARDS OF IGNITION OF FLAMMABLE ANAESTHETIC MIXTURES
17 - SECTION SEVEN: PROTECTION AGAINST EXCESSIVE TEMPERATURES AND OTHER SAFETY HAZARDS
17 - 44 Overflow, spillage, leakage, humidity, ingress of liquids, cleaning, sterilization and disinfection
17 - 44.2* Overflow
17 - 44.3* Spillage
17 - 44.4* Leakage
18 - 44.6* Ingress of liquids
18 - 49 Interruption of the power supply
19 - SECTION EIGHT: ACCURACY OF OPERATING DATA AND PROTECTION AGAINST HAZARDOUS OUTPUT
19 - 50 Accuracy of operating data
19 - 50.2 Accuracy of controls and instruments
20 - 51 Protection against hazardous output
20 - 51.1* Intentional exceeding of safety limits
20 - 51.101 Protection against electric hazards
20 - 51.102* Protection against accidental change of controls and tampering
21 - 51.103* Protection against a low battery condition
21 - 51.104* Rate limit (runaway protection)
21 - 51.105* Interference reversion
21 - 51.106* MAXIMUM TRACKING RATE
22 - SECTION NINE: ABNORMAL OPERATION AND FAULT CONDITIONS; ENVIRONMENTAL TESTS
22 - SECTION TEN: CONSTRUCTIONAL REQUIREMENTS
22 - 56 Components and general assembly
22 - 56.3 Connections - General
22 - 56.101* Output indicator
22 - 56.102* Input indicator
24 - Appendix L - References-Publications mentioned in this Standard
25 - Annex AA - General guidance and rationale
35 - Annex BB - Bibliography

Specifies the particular safety requirements for external pacemakers used to pace patients prior to the implanting of an internal pacemaker or for temporary pacing related to other medical procedures. This Standard is to be read in conjunction with AS 3200.1.0-1990. It is identical with and reproduced from IEC 601-2-31:1994.

Addition:This Particular International Standard specifies the particular safety requirements for EXTERNAL PACEMAKERS as defined in 2.1.101, hereinafter referred to as EQUIPMENT, poweredby an INTERNAL ELECTRICAL POWER SOURCE.This Standard applies to PATIENT CABLES as defined in 2.1.104.This Standard does not apply to EQUIPMENT which can be directly or indirectly connected toa SUPPLY MAINS.This Standard does not apply to pacing LEADS, or other equipment for cardiac stimulation which either:1) forms an integral part of equipment with other functions; or2) applies the stimulus across the thorax externally or in the oesophagus; or3) provides antitachycardia therapy beyond high rate burst pacing; or 4) provides pacing system analysis functions.Each of the two channels of DUAL CHAMBER EQUIPMENT is subject to the requirements of this Standard.

Committee
HE-003
DocumentType
Standard
ISBN
0 7337 0178 7
Pages
27
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

Standards Relationship
IEC 60601-2-31:1994 Identical

Amendment 1 to AS/NZS 3200.2.31:1996 see DR 98357 First published as Joint Standard AS/NZS 3200.2.31:1996.

AS 2176-1986 Primary batteries
AS/NZS 3200.1.2:2005 Medical electrical equipment General requirements for safety - Collateral standard: Electromagnetic compatibility - Requirements and tests
AS/NZS 3200.1.2:1995 Approval and test specification - Medical electrical equipment General requirements for safety - Collateral Standard: Electromagnetic compatibility - Requirements and tests

AS/NZS 60335.2.90:2006 Household and Similar Electrical Appliances - Safety Particular requirements for commercial microwave ovens
AS/NZS 60745.1:2009 Hand-held motor-operated electric tools-Safety General requirements (IEC 60745-1 Ed 4, MOD) (Reconfirmed 2020)
AS 4774.2-2002 Work in compressed air and hyperbaric facilities - Hyperbaric oxygen facilities

View more information
US$69.34
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.