AS/NZS 3808:1998

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Insulating and sheathing materials for electric cables
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-30-2017

Language(s)

English

Published date

01-01-1998

Preview

1 - AS/NZS 3808:1998 INSULATING AND SHEATHING MATERIALS FOR ELECTRIC CABLES
4 - PREFACE
4 - CONTENTS
5 - 1 SCOPE
5 - 2 REFERENCED DOCUMENTS
6 - 3 DEFINITIONS
6 - 3.1 Maximum continuous operating temperature
6 - 3.2 Sample tests
6 - 3.3 Type tests
6 - 3.4 Voltage designation
7 - 4 MATERIALS
7 - 4.1 Insulating material
8 - 4.2 Sheathing material
10 - 5 TESTS AND CRITERIA
10 - 5.1 Elastomeric materials
10 - 5.2 PVC materials
10 - 5.3 Fire performance materials
10 - 5.4 Polyolefin materials
24 - APPENDIX A - IDENTIFICATION OF MATERIALS IN OTHER RELEVANT STANDARDS

Specifies the tests and criteria, referenced in particular Standards, for elastomeric, PVC, fire performance and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords. It does not cover tests that can only be conducted on completed cables.

This Standard specifies the tests and criteria for elastomeric, PVC, fire performance and polyolefin insulating and sheathing materials used in the construction of electric cables and flexible cords and referenced in Australian and Australian/ New Zealand Standards. It applies to electric cables and cords designed for working voltages up to and including 19/33 kV. This Standard does not cover tests that can only be conducted on completed cables, e.g. partial discharge, tan d, impulse, high voltage, shrinkage and adhesion tests.The requirements of this Standard only apply when referenced in other relevant Standards. This Standard does not supersede requirements in existing Standards.

Committee
EL-003
DocumentType
Standard
ISBN
0 7337 1723 3
Pages
21
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes

Draft Amendment 1 see DR 99116 First published as AS/NZS 3808:1998.

AS 1979-1993 Electric cables - Lifts - Flexible travelling
AS 3599.1-1988 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Metallic screened
AS/NZS 1802:1995 Electric cables - Reeling and trailing - For underground coal mining purposes
AS 1049-1996 Telecommunication cables - Insulation, sheath and jacket
AS 3147-1992 Approval and test specification - Electric cables - Thermoplastic insulated - For working voltages up to and including 0.6/1 kV
AS 2276.2-1986 Cables for traffic signal installations - Feeder cable for vehicle detectors
AS 3158-1994 Approval and test specification - Electric cables - Glass fibre insulated for working voltages up to and including 0.6/1 kV
AS 2276.3-1992 Cables for traffic signal installations - Loop cable for vehicle detectors
AS 3008.1-1989 Electrical installations - Selection of cables - Cables for alternating voltages up to and including 0.6/1 kV
AS 3675-1993 Conductors - Covered overhead - For working voltages 6.35/11 kV up to and including 19/33 kV
AS/NZS 3116:1996 Approval and test specification - Electric cables - Elastomer insulated - For working voltages up to and including 0.6/1 kV
AS/NZS 3187:1995 Approval and test specification - Mineral-insulated metal-sheathed cables
AS/NZS 4193.3:1994 Electric cables for use in ships Sheathing materials for shipboard power, control and telecommunication cables
AS/NZS 1995:1995 Welding cables
AS/NZS 4193.2:1994 Electric cables for use in ships Insulating materials for shipboard power cables
AS 2122.1-1993 Combustion characteristics of plastics Determination of flame propagation - Surface ignition of vertically oriented specimens of cellular plastics
AS 3178-1991 Approval and test specification - Electric cables - Silicone rubber insulated - For working voltages up to and including 0.6/1 kV
AS/NZS 3155:1995 Approval and test specification - Electric cables - Neutral screened - For working voltages up to and including 0.6/1 kV
AS/NZS 3198:1996 Approval and test specification - Electric cables - XLPE insulated - For working voltages up to and including 0.6/1 kV
AS 1178-1986 Concentric wire neutral cables - XLPE insulated - For electricity supply at working voltages of 0.6/1 kV
AS/NZS 3166:1993 Approval and test specification - Cables for high voltage luminous discharge tube installations (Reconfirmed 2017)
AS 3599.2-1991 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS/NZS 3191:1996 Approval and test specification - Electric flexible cords
AS 4026-1992 Electric cables - For underground residential distribution systems
AS 2276.1-1992 Cables for traffic signal installations - Multicore power cables
AS/NZS 2373.2:1995 Electric cables for control and protection circuits - Twisted pair control cables
AS/NZS 2373.1:1995 Electric cables for control and protection circuits Multicore control cables
AS 1429.1-1993 Electric cables - Polymeric insulated - For working voltages 1.9/3.3 (3.6) kV up to and including 19/33 (36) kV
AS 2802-1992 Electric cables - Reeling and trailing - For mining and general use (other than underground coal mining)
AS 1026-1992 Electric cables - Impregnated paper insulated - Working voltages up to and including 33 kV
AS 3560-1991 Electric cables - XLPE insulated - Aerial bundled - For working voltages up to and including 0.6/1 kV

AS/NZS 3560.1:2000 Electric cables - Cross-linked polyethylene insulated - Aerial bundled - For working voltages up to and including 0.6/1(1.2) kV Aluminium conductors (Reconfirmed 2021)
AS/NZS 3599.2:1999 Electric cables - Aerial bundled - Polymeric insulated - Voltages 6.35/11(12) kV and 12.7/22(24) kV Non-metallic screened
AS/NZS 2276.2:1998 Cables for traffic signal installations Feeder cable for vehicle detectors
AS/NZS 3000:2000 Electrical installations (known as the Australian/New Zealand Wiring Rules)

View more information
US$60.92
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.