Safety of power transformers, power supply units and similar products Particular requirements for transformers for class III handlamps for tungsten filament lamps (IEC 61558-2-9:2002, MOD)
Available format(s)

Hardcopy , PDF 1 User , PDF 3 Users , PDF 5 Users , PDF 9 Users

Superseded date

06-25-2021

Language(s)

English

Published date

05-30-2003

1 - AS/NZS 61558.2.9:2003 SAFETY OF POWER TRANSFORMERS, POWER SUPPLY UNITS AND SIMILAR PRODUCTS - PARTICULAR REQUIREMENTS FOR...
4 - CONTENTS
5 - FOREWORD
7 - 1 Scope
8 - 2 Normative references
8 - 3 Definitions
8 - 4 General requirements
8 - 5 General notes on tests
8 - 6 Ratings
8 - 7 Classification
9 - 8 Marking and other information
9 - 9 Protection against accessibility of hazardous live parts
10 - 10 Change of input voltage setting
10 - 11 Output voltage and output current under load
10 - 12 No-load output voltage
11 - 13 Short-circuit voltage
11 - 14 Heating
11 - 15 Short-circuit and overload protection
11 - 16 Mechanical strength
11 - 17 Protection against harmful ingress of dust, solid objects and moisture
11 - 18 Insulation resistance and dielectric strength
11 - 19 Construction
13 - 20 Components
13 - 21 Internal wiring
13 - 22 Supply connection and other external flexible cables or cords
14 - 23 Terminals for external conductors
14 - 24 Provision for protective earthing
14 - 25 Screws and connections
14 - 26 Creepage distances, clearances and distances through insulation
14 - 27 Resistance to heat, abnormal heat, fire, and tracking
14 - 28 Resistance to rusting
15 - Annexes
16 - Annex ZZ - Variations to IEC 61558-2-9:2002 for application in Australia and New Zealand

Specifies general safety requirements for approval and test purposes for transformers for class III handlamps for tungsten filament lamps. This Standard is an adoption with national modifications and contains the full text of IEC 61558-2-9:2002.

Replacement:This International Standard covers such aspects of safety as electrical, thermal and mechanical. This Part 2-9 of IEC 61558 applies to stationary or portable single-phase air-cooled (natural or forced) associated safety isolating transformers for class III handlamps for tungsten filament lamps, having a rated supply voltage not exceeding 1 000 V a.c., a rated frequency not exceeding 500 Hz and a rated output not exceeding 10 kVA. Transformers for class III handlamps for tungsten filament lamps - have a no-load output voltage and a rated output voltage not exceeding 50 V a.c. or 120 V ripple-free d.c.;- are used where double or reinforced insulation between circuits is required by the installation rules or by the appliance specification;- have a low variation between no-load and rated output voltage;- have a limited output voltage.This standard is applicable to dry-type transformers. The windings may be encapsulated or non-encapsulated. NOTE 1 For transformers filled with liquid dielectric or pulverised material, such as sand, additional requirements are under consideration. NOTE 2 Attention is drawn to the fact that for transformers intended to be used in vehicles, on board ships and aircraft, additional requirements (from other applicable standards, national rules, etc.) may be necessary; for transformers intended for use in tropical areas, measures to protect the enclosure and the components inside the enclosure against external influences like fungus, vermin and termites should also be considered; in locations where special environmental conditions prevail, additional requirements (from other applicable standards, national rules, etc.) may be necessary. This standard also applies to transformers incorporating electronic circuits. This standard does not apply to external circuits and their components intended to be connected to the input and output terminals or socket-outlets of the transformer.

Committee
EL-002
DocumentType
Standard
ISBN
0 7337 5380 9
Pages
10
PublisherName
Standards Australia
Status
Superseded
SupersededBy
Supersedes
UnderRevision

AS 3108 first published in Australia in part as AS C126-1939.Second edition 1958.AS C167 first published 1962.Revised and redesignated AS 3167-1981 (withdrawn 1987).AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989).AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984.Revised, amalgamated and redesignated AS 3108-1990.First published in New Zealand as NZS/AS 3108:1990.Jointly revised and designated as Joint Standard AS/NZS 3108:1994.Jointly revised and redesignated in part as AS/NZS 61558.2.9:2003. AS 3108 first published in Australia in part as AS C126-1939. Second edition 1958. AS C167 first published 1962. Revised and redesignated AS 3167-1981 (withdrawn 1987). AS C126-1958 revised and redesignated AS 3126-1981 (withdrawn 1989). AS 3126-1981 and AS 3167-1981 revised and redesignated AS 3108.1-1984, AS 3108.2-1984 and AS 3108.3-1984. Revised, amalgamated and redesignated AS 3108-1990. First published in New Zealand as NZS/AS 3108:1990. Jointly revised and designated as Joint Standard AS/NZS 3108:1994. Jointly revised and redesignated in part as AS/NZS 61558.2.9:2003.

AS 2703-2008 Vehicle loop detector sensors
AS/NZS 4836:2011 Safe working on or near low-voltage electrical installations and equipment
AS 2865-2009 Confined spaces
AS/NZS 3439.4:2009 Low-voltage switchgear and controlgear assemblies Particular requirements for assemblies for construction sites (ACS)
AS/NZS 3197:2005 Approval and test specification - Portable electrical control or conditioning devices
AS/NZS 3004.2:2008 Electrical installations - Marinas and recreational boats Recreational boats installations
AS 2144:2014 Traffic signal lanterns
AS/NZS 3105:2014 Approval and test specification - Electrical portable outlet devices
AS/NZS 3000:2007 Electrical installations (known as the Australian/New Zealand Wiring Rules)
AS 2832.3-2005 Cathodic protection of metals Fixed immersed structures
AS/NZS 3000:2018 (Unamended Hardcopy + Amendments) Electrical installations (known as the Australian/New Zealand Wiring Rules)

View more information
US$65.36
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.