PERFORMANCE TEST CODES - ATMOSPHERIC WATER COOLING EQUIPMENT
Available format(s)

Hardcopy , PDF

Superseded date

08-17-2023

Language(s)

English

Published date

01-01-2014

Foreword
Committee Roster
Correspondence with the PTC 23 Committee
Introduction
Section 1 - Object and Scope
Section 2 - Definitions and Description
            of Terms
Section 3 - Guiding Principles
Section 4 - Instruments and Methods of
            Measurement
Section 5 - Calculations and Results
Section 6 - Report of Results
Nonmandatory Appendices
A - Performance Monitoring
B - Ultrasonic Flowmeters
C - Tracer Dilution Method for Water
    Flow Determination
D - Uncertainty Calculation
E - Sample Calculation for Mechanical Draft
    Towers
F - Sample Calculation for Natural Draft Towers
G - Sample Calculation for Plume Compliance
H - Sample Calculation for Closed-Circuit
    Evaporative Coolers
I - Sample Calculation for Wet Surface Air-Cooled
    Condensers (WSACC)
J - Illustrations of Cooling Equipment
K - Other Methods for Air Temperature Measurement
L - Reporting Forms
M - References

This Code provides uniform test methods for conducting and reporting thermal performance characteristics of wet mechanical draft, natural draft, wet-dry cooling towers, closed circuit evaporative (wet) coolers, and wet surface air-cooled steam condensers (WSACC). This Code also provides directions and rules for conducting and reporting plume abatement of wet-dry cooling towers and water consumption of any cooling tower. The purpose of this Code is to provide rules for monitoring thermal performance or for conducting acceptance tests on all of the cooling equipment referenced above. It provides rules for monitoring plume abatement and conducting plume-abatement acceptance tests on wet-dry cooling towers. The test can be used to determine compliance with contractual obligations and can be incorporated into commercial agreements. A test shall be considered an ASME Code Test only if the test procedures comply with those allowed in this Code and the post-test uncertainty analysis results are in accord with subsection 1.3. This Code provides rules for determining the performance of all referenced cooling equipment with regard to the thermal capability, deviation from design thermal capability, or deviation from design cold water temperature. This Code also provides procedures for assessing the compliance to specified plume abatement requirements characteristic of a wet-dry cooling tower. It is not intended for tests of atmospheric wind towers, dry coolers, spray canals, or ponds, although sections of this Code may be useful for that purpose. The determination of special data or verification of guarantees that are outside the scope of this Code, shall be made only with written agreement of the parties to the test. The agreed methods of measurement and computation shall be defined in writing and fully described in the test report.

DocumentType
Standard
ISBN
079182831X
Pages
124
ProductNote
Reconfirmed 2014
PublisherName
American Society of Mechanical Engineers
Status
Superseded
SupersededBy
Supersedes

CTI ATC 105 : 2000 ACCEPTANCE TEST CODE FOR WATER COOLING TOWERS
ASME PTC19.1 : 2013 TEST UNCERTAINTY
ASHRAE HDBK FUNDAMENTALS : 2013 ASHRAE HANDBOOK - FUNDAMENTALS
CTI ATC 140 : 2011 ISOKINETIC DRIFT TEST CODE
CTI STD 146 : 0 STANDARD FOR LIQUID FLOW MEASUREMENT

View more information
US$138.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.