• There are no items in your cart

ASTM D 5812 : 1996 : R2002 : EDT 1

Withdrawn
Withdrawn

A Withdrawn Standard is one, which is removed from sale, and its unique number can no longer be used. The Standard can be withdrawn and not replaced, or it can be withdrawn and replaced by a Standard with a different number.

Standard Test Method for Determination of Organochlorine Pesticides in Water by Capillary Column Gas Chromatography (Withdrawn 2011)
Available format(s)

Hardcopy , PDF

Withdrawn date

01-01-2011

Language(s)

English

Published date

05-10-1996

CONTAINED IN VOL. 11.02, 2009 Covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined.

1.1 This test method covers the capillary gas chromatographic determination of various organochlorine pesticides, including some of their degradation products and related compounds in finished drinking water. This test method is not limited to this particular aqueous matrix; however, its applicability to other aqueous matrices must be determined. The tested compounds include the following:

Numbering system of CAS Registry Services, P.O. Box 3343, Columbus, OH 43210-0334.

PesticideChemical Abstract Service Registry Number
Aldrin309-00-2
-BHC319-84-6
-BHC319-85-7
-BHC319-86-8
-BHC58-89-9
-Chlordane5103-71-9
-Chlordane5103-74-2
Chlorobenzilate501-15-6
Chloroneb2675-77-6
Chlorothalonil2921-88-2
DCPA1897-45-6
4,4`-DDD72-54-8
4,4`-DDE72-55-9
4,4`-DDT50-29-3
Dieldrin60-57-1
Endosulfan I959-98-8
Endosulfan II33213-65-9
Endosulfan sulfate1031-0708
Endrin72-20-8
Endrin aldehyde7421-93-4
Etridiazole2593-15-9
Heptachlor76-44-8
Heptachlor epoxide1024-57-3
Hexachlorobenzene118-74-1
Methoxychlor72-43-5
cis-Permethrin52645-53-1
trans-Permethrin52645-53-1
Propachlor1918-16-7
Trifluralin1582-09-8

1.2 and list the applicable concentration ranges and precision and bias statements for this test method. The applicability of this test method to other compounds must be demonstrated.

1.3 The extract derived from this procedure may be analyzed for these constituents by using the gas chromatography (GC) conditions prescribed in Test Method D 5175 (capillary column). Although the columns used in this test method may be adequate for analyzing PCBs, no data were collected for any multi-congener constituents during methods development.

1.4 This test method is restricted to use by or under the supervision of analysts experienced in the use of GC and interpretation of gas chromatograms. Each analyst must demonstrate the ability to generate acceptable results using the procedures described in Section 12.

1.5 Analytes that are not separated chromatographically by either the primary or secondary chromatographic columns (for example, analytes having very similar retention times) cannot be identified and measured individually in the same calibration mixture or water sample unless an alternative technique for identification and quantitation exists (see 7.9 and 13.4).

1.6 When this test method is used to analyze unfamiliar samples for any or all of the analytes listed in 1.1, analyte identifications and concentrations should be confirmed by at least one additional technique.

1.7 The values stated in SI units are to be regarded as the standard.

1.8 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazards statements are given in Section 9.

Committee
D 19
DevelopmentNote
Supersedes ASTM D 3086 (12/2001)
DocumentType
Test Method
Pages
12
ProductNote
Reconfirmed EDT 1
PublisherName
American Society for Testing and Materials
Status
Withdrawn
Supersedes

ASTM D 3694 : 1996 : R2017 Standard Practices for Preparation of Sample Containers and for Preservation of Organic Constituents

ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM D 2777 : 2013 : REDLINE Standard Practice for Determination of Precision and Bias of Applicable Test Methods of Committee D19 on Water
ASTM E 260 : 1996 Standard Practice for Packed Column Gas Chromatography
ASTM D 1192 : 1998 Standard Guide for Equipment for Sampling Water and Steam in Closed Conduits (Withdrawn 2003)

View more information
US$83.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.