• There are no items in your cart

ASTM D 6330 : 1998 : R2014

Superseded
Superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

View Superseded by
superseded

A superseded Standard is one, which is fully replaced by another Standard, which is a new edition of the same Standard.

Standard Practice for Determination of Volatile Organic Compounds (Excluding Formaldehyde) Emissions from Wood-Based Panels Using Small Environmental Chambers Under Defined Test Conditions
Available format(s)

Hardcopy , PDF

Superseded date

08-12-2020

Language(s)

English

Published date

11-01-2014

CONTAINED IN VOL. 11.03, 2015 Evaluates the volatile organic compounds (VOC) but excludes formaldehyde, emitted from manufactured wood-based panels.

1.1The practice measures the volatile organic compounds (VOC), excluding formaldehyde, emitted from manufactured wood-based panels. A pre-screening analysis is used to identify the VOCs emitted from the panel. Emission factors (that is, emission rates per unit surface area) for the VOCs of interest are then determined by measuring the concentrations in a small environmental test chamber containing a specimen. The test chamber is ventilated at a constant air change rate under the standard environmental conditions. For formaldehyde determination, see Test Method D6007.

1.2This practice describes a test method that is specific to the measurement of VOC emissions from newly manufactured individual wood-based panels, such as particleboard, plywood, and oriented strand board (OSB), for the purpose of comparing the emission characteristics of different products under the standard test condition. For general guidance on conducting small environmental chamber tests, see Guide D5116.

1.3VOC concentrations in the environmental test chamber are determined by adsorption on an appropriate single adsorbent tube or multi-adsorbent tube, followed by thermal desorption and combined gas chromatograph/mass spectrometry (GC/MS) or gas chromatograph/flame ionization detection (GC/FID). The air sampling procedure and the analytical method recommended in this practice are generally valid for the identification and quantification of VOCs with saturation vapor pressure between 500 and 0.01 kPa at 25°C, depending on the selection of adsorbent(s).

Note 1:VOCs being captured by an adsorbent tube depend on the adsorbent(s) and sampling procedure selected (see Practice D6196). The user should have a thorough understanding of the limitations of each adsorbent used.

1.4The emission factors determined using the above procedure describe the emission characteristics of the specimen under the standard test condition. These data can be used directly to compare the emission characteristics of different products and to estimate the emission rates up to one month after the production. They shall not be used to predict the emission rates over longer periods of time (that is, more than one month) or under different environmental conditions.

1.5Emission data from chamber tests can be used for predicting the impact of wood-based panels on the VOC concentrations in buildings by using an appropriate indoor air quality model, which is beyond the scope of this practice.

1.6The values stated in SI units shall be regarded as the standard (see IEEE/ASTM SI-10).

1.7This practice does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of the standard to consult and establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. For specified hazard statements see Section 6.

Committee
D 22
DocumentType
Standard Practice
Pages
10
ProductNote
Reconfirmed 2014
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM D 5116 : 2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
ASTM D 7143 : 2017 Standard Practice for Emission Cells for the Determination of Volatile Organic Emissions from Indoor Materials/Products
ASTM D 8141 : 2017 Standard Guide for Selecting Volatile Organic Compounds (VOCs) and Semi-Volatile Organic Compounds (SVOCs) Emission Testing Methods to Determine Emission Parameters for Modeling of Indoor Environments
ASTM D 7911 : 2014 Standard Guide for Using Reference Material to Characterize Measurement Bias Associated with Volatile Organic Compound Emission Chamber Test

ASTM E 380 : 1993 Standard Practice for Use of the Internation System of Units (SI) (the Modernized Metric System) (Withdrawn 1997)
ASTM D 1356 : 2015 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6196 : 1997 Standard Practice for Selection of Sorbents and Pumped Sampling/Thermal Desorption Analysis Procedures for Volatile Organic Compunds in Air
ASTM D 5116 : 2006 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products
ASTM D 1356 : 2017 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6007 : 2014 Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber
ASTM D 6196 : 2003 : R2009 Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air
ASTM D 1356 : 2015 : REV B Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5116 : 2010 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions From Indoor Materials/Products
IEEE/ASTM SI_10-2010 American National Standard for Metric Practice
ASTM D 6196 : 2015 : EDT 1 Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air
ASTM D 6196 : 2015 Standard Practice for Choosing Sorbents, Sampling Parameters and Thermal Desorption Analytical Conditions for Monitoring Volatile Organic Chemicals in Air
ASTM D 1356 : 2014 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5116 : 2017 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products
ASTM D 1914 : 1995 : R1999 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis Atmospheres
ASTM D 1356 : 2015 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2005 : R2010 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6007 : 2002 : R2008 Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber
ASTM D 6196 : 2003 Standard Practice for Selection of Sorbents, Sampling, and Thermal Desorption Analysis Procedures for Volatile Organic Compounds in Air
ASTM D 1356 : 2020 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6007 : 2002 Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber
ASTM D 1914 : 1995 : R2014 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2000 : REV A Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 5116 : 1997 Standard Guide for Small-Scale Environmental Chamber Determinations of Organic Emissions from Indoor Materials/Products (Withdrawn 2006)
ASTM D 1356 : 2014 : REV B Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1356 : 2014 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 1914 : 1995 : R2010 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres
ASTM D 6007 : 2014 : REDLINE Standard Test Method for Determining Formaldehyde Concentrations in Air from Wood Products Using a Small-Scale Chamber
ASTM D 1356 : 2005 Standard Terminology Relating to Sampling and Analysis of Atmospheres
ASTM D 6007 : 1996 Standard Test Method for Determining Formaldehyde Concentration in Air from Wood Products Using a Small Scale Chamber
ASTM D 1914 : 1995 : R2004 : EDT 1 Standard Practice for Conversion Units and Factors Relating to Sampling and Analysis of Atmospheres

View more information
US$75.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.