Standard Guide for Conducting Static Toxicity Tests with Microalgae
Available format(s)

Hardcopy , PDF

Superseded date

11-11-2014

Language(s)

English

Published date

04-01-2004

CONTAINED IN VOL. 11.06, 2014 Describes procedures for obtaining laboratory data concerning the adverse effects of a test material added to growth medium on growth of certain species of freshwater and saltwater microalgae during a static exposure.

1.1 This guide covers procedures for obtaining laboratory data concerning the adverse effects of a test material added to growth medium on growth of certain species of freshwater and saltwater microalgae during a static exposure. These procedures will probably be useful for conducting short-term toxicity tests with other species of algae, although modifications might be necessary. Although the test duration is comparable to an acute toxicity test with aquatic animals, an algal toxicity test of short duration (72, 96 or 120 h) allows for examination of effects upon multiple generations of an algal population and thus should not be viewed as an acute toxicity test.

1.2 Other modifications of these procedures might be justified by special needs or circumstances. Although using appropriate procedures is more important than following prescribed procedures, results of tests conducted using unusual procedures are not likely to be comparable to results of many other tests. Comparison of results obtained using modified and unmodified versions of these procedures might provide useful information concerning new concepts and procedures for conducting toxicity tests with microalgae.

1.3 These procedures are applicable to many chemicals, either individually or in formulations, commercial products, or known mixtures. With appropriate modifications, these procedures can be used to conduct tests on temperature, and pH and on such materials as aqueous effluents (see also Guide E 1192), leachates, oils, particulate matter, sediments, and surface waters. Static tests might not be applicable to materials that are highly volatile, are rapidly biologically or chemically transformed in aqueous solutions, or are removed from test solutions in substantial quantities by the test vessels or organisms during the test. However, practical flow-through test procedures with microalgae have not been developed.

1.4 Results of tests using microalgae should usually be reported in terms of the 96-h (or other time period) IC50 (see ) based on reduction in growth. In some situations, it might only be necessary to determine whether a specific concentration unacceptably affects the growth of the test species or whether the IC50 is above or below a specific concentration.

1.5 This guide is arranged as follows:

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific hazard statements are given in Section 7.

Committee
E 47
DocumentType
Guide
Pages
14
ProductNote
Reconfirmed EDT 1
PublisherName
American Society for Testing and Materials
Status
Superseded
SupersededBy
Supersedes

ASTM E 1841 : 2004 : R2012 Standard Guide for Conducting Renewal Phytotoxicity Tests With Freshwater Emergent Macrophytes (Withdrawn 2021)
ASTM E 1850 : 2004 : R2019 Standard Guide for Selection of Resident Species as Test Organisms for Aquatic and Sediment Toxicity Tests
ASTM E 1733 : 1995 : R2014 Standard Guide for Use of Lighting in Laboratory Testing
ASTM E 1415 : 1991 : R2012 Standard Guide for Conducting Static Toxicity Tests With <i>Lemna gibba</i> G3 (Withdrawn 2021)
ASTM E 2317 : 2004 : R2012 Standard Guide for Conducting Renewal Microplate-Based Life-Cycle Toxicity Tests with a Marine Meiobenthic Copepod (Withdrawn 2021)

ASTM E 380 : 1993 Standard Practice for Use of the Internation System of Units (SI) (the Modernized Metric System) (Withdrawn 1997)
ASTM D 1129 : 2013 : REDLINE Standard Terminology Relating to Water
ASTM E 1733 : 1995 Standard Guide for Use of Lighting in Laboratory Testing
ASTM D 4447 : 2015 : REDLINE Standard Guide for Disposal of Laboratory Chemicals and Samples
ASTM E 1847 : 1996 Standard Practice for Statistical Analysis of Toxicity Tests Conducted Under ASTM Guidelines
ASTM E 729 : 1996 Standard Guide for Conducting Acute Toxicity Tests on Test Materials with Fishes, Macroinvertebrates, and Amphibians

View more information
US$83.00
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.