MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR LUNG VENTILATORS
Available format(s)

Hardcopy , PDF

Superseded date

11-15-1997

Language(s)

English

Published date

01-01-1990

Committees responsible
National foreword
Section one: General
Clause
1. Scope and object
1.1 Scope
2. Terminology and definitions
3. General requirements
4. General requirements for tests
5. Classification
6. Identification, marking and documents
6.8 Accompanying documents
7. Power input
Section two: Safety requirements
8. Basic safety categories
9. Removable protective means
12. Single fault condition
Section three: Protection against electric shock hazards
17. Insulation and protective impedances
18. Earthing and potential equalization
19. Continuous leakage currents and patient auxiliary
     currents
20. Dielectric strength
Section four: Protection against mechanical hazards
Section five: Protection against hazards from unwanted
or excessive radiation
Section six: Protection against the hazards of explosions
in medically used rooms
Section seven: Protection against excessive temperatures,
fire and other hazards, such as human errors
42. Excessive temperatures
43. Fire prevention
44. Overflow, spillage, leakage, humidity, ingress of
     liquids, cleaning, sterilization and disinfection
44.3 Spillage
49. Interruption of the power supply
Section eight: Accuracy of operating data and protection
against incorrect output
Section nine: Fault conditions causing overheating and/
or mechanical damage; environmental tests
Section ten: Constructional requirements
56. Components and general assembly
57. Mains parts, components and layout
Appendix
AA. Rationale

Describes safety requirements for LUNG VENTILATORS with electrical devices designed for medical use. Non-electrical requirements, and some safety requirements, are given in ISO 5369 - 1977: Breathing machines for medical use - Lung ventilators. Includes sections on protection against electric shock, mechanical hazards, excess radiation, explosions in medically used rooms, excess temperatures, fire etc., accuracy of operating data and protection against incorrect output, fault conditions, mechanical damage, environmental tests, and constructional requirements.

Committee
HCC/46
DevelopmentNote
IMPLEMENTS CENELEC HD 395.2.12
DocumentType
Standard
Pages
22
PublisherName
British Standards Institution
Status
Superseded
SupersededBy

Standards Relationship
IEC 60601-2-12:2001 Identical

BS 5724-2.13(1990) : 1990 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR ANAESTHETIC MACHINES

BS 5724-2.13(1990) : 1990 MEDICAL ELECTRICAL EQUIPMENT - PARTICULAR REQUIREMENTS FOR SAFETY - SPECIFICATION FOR ANAESTHETIC MACHINES
ISO 5369:1987 Breathing machines for medical use Lung ventilators

View more information
US$160.51
Excluding Tax where applicable

Access your standards online with a subscription

Features

  • Simple online access to standards, technical information and regulations.

  • Critical updates of standards and customisable alerts and notifications.

  • Multi-user online standards collection: secure, flexible and cost effective.